NAVY MIL-W-18445 D-1980 WINDOWS NON-ICING LAMINATED FLAT GLASS ELECTRICALLY HEATED WITH CONTROLS《电热控制的叠层平板不结冰玻璃窗户》.pdf

上传人:proposalcash356 文档编号:983194 上传时间:2019-03-12 格式:PDF 页数:17 大小:701.76KB
下载 相关 举报
NAVY MIL-W-18445 D-1980 WINDOWS NON-ICING LAMINATED FLAT GLASS ELECTRICALLY HEATED WITH CONTROLS《电热控制的叠层平板不结冰玻璃窗户》.pdf_第1页
第1页 / 共17页
NAVY MIL-W-18445 D-1980 WINDOWS NON-ICING LAMINATED FLAT GLASS ELECTRICALLY HEATED WITH CONTROLS《电热控制的叠层平板不结冰玻璃窗户》.pdf_第2页
第2页 / 共17页
NAVY MIL-W-18445 D-1980 WINDOWS NON-ICING LAMINATED FLAT GLASS ELECTRICALLY HEATED WITH CONTROLS《电热控制的叠层平板不结冰玻璃窗户》.pdf_第3页
第3页 / 共17页
NAVY MIL-W-18445 D-1980 WINDOWS NON-ICING LAMINATED FLAT GLASS ELECTRICALLY HEATED WITH CONTROLS《电热控制的叠层平板不结冰玻璃窗户》.pdf_第4页
第4页 / 共17页
NAVY MIL-W-18445 D-1980 WINDOWS NON-ICING LAMINATED FLAT GLASS ELECTRICALLY HEATED WITH CONTROLS《电热控制的叠层平板不结冰玻璃窗户》.pdf_第5页
第5页 / 共17页
点击查看更多>>
资源描述

1、MIL-W-18445D(SH)29 December 1980SUPERSEDING-MIL-ti-18445C(SH1PS)15 October 1968 - -(See 6*5)MILITARY SPECIFICATIONWiNDOWS, NON-ICING, LAMINArED FLAT ”GLASS,ELECTRICALLY HEATED WIiHCONTROLSThis specification is approved for use by the Naval. Sea SystemsCommand, Department of the Navy, and is availabl

2、e for use by allDepartments and Agencies of the Department of Defense.1. SCOPE.,1.1 Scope. ,This specification .covers non-icing, flat laminated, elec-trically heated glass windows contained in metal frames, with temperaturecontrols necessary for operation. The windows are to provide clear visionabo

3、ard ships during cold weather”operating conditions.1.2 Classification. Controllers shall be of the following types, asspecified (see 6.2.1): ,. ,Type I -Type 11 -,-2. APPLICABLERemote controller actuated by a temperature sensorembedded in the window. ,Surface controller actuated by an integral tempe

4、raturesensor forcontroller replacement on windows not havingembedded sensors.DOCUME?JTS.2.1 Issues of documents. The following documents, of the issue in effecton date of invitation for bids or request for proposal, form a part of thisspecification to the extent specified herein.,Beneficial commen”t

5、s (recommendations:, additions; deletions) and any pertinentdata which may be of use in improving this document should be addressed to:Commander, Naval Sea Systems Co ShipboardMachinery, Equipment and Systems,Requirements for.Electric Power Equipment, Basic Requirements for(Naval Shipboard Use).Glas

6、s, Heat-Treated, Glazing, Rectangular(For Bridge Windows).Glass, Laminated, Flat; (Except Aircraft).Connectors, Electric, “AN” Type, GeneralSpecification for.Enamel, .Equipment,Light-Gray (Formula No. 111).Primer, (Wash), Pretreatment, (Formula No. 117For Metals) (Metric).Electronic and Electrical E

7、quipment, Accessories,and Repair Parts; Packaging and Packing of.Plastics: Methods of Testing. .Sampling Procedures and Tables for Inspectionby Atributes.Marking for Shipment and Storage.Identification Marking of U.S. Military Property.Mechanical Vibration of Shipboard Equipment (Type I -Environment

8、al and Type 11 - Internally Excited).Wired Equipment, Classification of Visual andMechanical Defects. .Electromagnetic Emission and Susceptibility Require-ments for the Control of Electromagnetic Interference.Reliability Design Qualification and ProductionsAcceptance Tests: Exponet.ialDistribution.C

9、ushioning, Anchoring, Bracing, Blocking, andWaterproofing; With Appropriate Test Methods.Interface Standard for Shipboard Systems, ElectricPower, Alternating Current (Metric).2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DRAWINGSMIL-w-18445D(sH)NA

10、V.AL SEA SYSTEMS COMMAND:805-1633251 - Window, ”Heated, 3“/q”Inch Panel (CRES), Details,19 by25. ,805-1633254 - 2 Inch Panel.(CRES), Details, “Window, Heated,”19 by 25.805-163327 - Window, Heated, l/2”I”nchPanel (CRES), Details,19 by 25.805-1633259 - Window, Heated, 1/2Inch Panel, Hinged Frame (CRES

11、)Assembly, 19 by 25.i05-1633260, - Window, He,ated,l/2 InchPanel (CRES and A.Lurninumj,Hinged Frame Details, 19 by 25.805-1633261 - Jindow, lieated 1/2 Inch panel, Fixe,i”Frame (AL),19 by 25.805-1633262 - Window, Heated, .L/2 Inch Panel, Details (AL) 19. by 25.805-1633263 - Ji.ndOwIleated;1/2 Inch P

12、anel: Hinged Frame(AL)Assembly .19by 25.805-1633264 - Window, Heated, 1/2 Inch Panel, Details (AL), 19 by 25.805-2226902 - Window, Heated Temperature Control and Glass Detail.805-4353964 - Temperature Controller,.Type 11 For Heated Windows(Surface Mounted Sensor).(Copies of specifications,standards,

13、drawings, and publications required bycontractors in connection with specific acquisition functions should be obtainedfrom the contracting activity or as directed by the contracting officer.)2.2 Other publications. The following documents form a part of this specifi-cation to the extent specified he

14、rein. Unless otherwise indicated, the issue in.effect on date of invitation for bids or request for proposal shall apply. .UNIFORMCLASSIFICATIONCO!IMITTEEUniform Freight Classification Ratings, Rules and Regulations(Application for copies should be addressed to the Uniform ClassificationCommittee Ag

15、ent, Tariff Publication Officer, Room 1106, 222 South RiversidePlaza, Chicago, Illinois 60606.)NATIONAL CLASSIFICATION BOARDNational Hotor Freight Classification Classes and Rules(Application for copies should be addressed to the ATA Tariff Section,1616 P Street, N.W., Washington, DC 20036.)(Technic

16、al society andtechriical association specifications and standardsare generally available for reference from libraries. They are also distributedainong technical groups and using Federal agencies.)3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-w

17、-18445D(SH)3. REQUIREMENTS3.1 Sample for first article inspection. Prior to beginning production acontroller sample shall be tested as specified in 4.3 (see 6.3).3.2 General requirements. Controllersshall be built to the generalrequirements of MIL-E-917. Ordinary maintenance in service shall not req

18、uirespecial tools, excessively precise workmanship, or critical adjustments,.3.2.1 Recovered materials. Unless otherwise specified herein, all equip-ment, material, and articles incorporated in the products covered by this specifi-cation shall be new and shall be fabricated using materials produced

19、from recoveredmaterials to the maximum extent practicable without jeopardizing the intended use.The term “recovered materials” means materials which have been collected or recoveredfrom solid waste and reprocessed to become a source of raw materials; as opposed tovirgin raw materials. None of the ab

20、ove shall be interpreted to mean that the useof used or rebuilt products is allowed under this specification unless otherwisespecifically specified.3.3 Construction.3.3.1 Windows. Windows”shall be constructed of laminated glass which isfree of all notches and of two or more plies of glass of glazing

21、 qualities conformingto MIL-G-2857. The laminate shall conform to class 1, type I of MIL-G-3787.This plastic shall have a 20 percent nominal plasticizer content. A partingmedium may be used at the option of the contractor.” Glass plies or plasticinterlayer shall not be notched or drilled. The flat l

22、aminated glass panel shallbe coated with a transparentelectrically conductive stannic oxide film. Contactwith the conductive film shall be maintained through bus bars that have been firedto the glass substrate prior to application of the film. Windows shall contain twotemperature sensors (one spare)

23、 embedded within the plastic interlayer and shalluse a type I controller (see 1.2).3.3.1.1 Sensor characteristics. Embedded sensors used with type I controllersshall have the following characteristics:nominal at 90F(a) Sensor material: Nickel wire.(b) Resistance: 326 ohms + lpercent at 90”F.(c) Temp

24、erature coe!?ficien: 0.003 ohms/ohm/F(measured at the input to the controller).(d) Size: Approximately 1-1/2 inches by 1-1/2 inches.(e) Location: Conforming to Drawing 805-2226902.3.3.1.2 Frames. The glass shall be contained in frames of corrosion resistingsteel (CRKS), bronze, or aluminum as specif

25、ied (see 6.2;1). Details shall be asindicated on Drawings 805-1633251, 805-1633254, 805-1633257, 805-1633259, 805-1633260, 805-1633261, 805-1633262, 805-1633263, and 805-1633264, as applicable.Gaskets of l/8-inch thickness shall be provided to enable window frames to beinstalled.,.3.3.1.3 Gaskets. T

26、he glass shall be fitted in the frame by means of arubber channel gasket of 30 to 40 durometers. Corners of gaskets shall bevulcanized or otherwise sealed against water penetration.4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-w-18,445.D(S1-1)

27、3.3.1.4 Junction box. The .-junction box used for ,terminatingsensor leadsshall be of st”eel”and painted in accordancewitheither or the following methods:(a) One coat of wash pretreatment in accordaricewith DOD-P-15328:.(0.0005- to 0.0007-inch thick).(b) A hot dip-tank phosphate treatment corirminto

28、 type I of .TT-C-49, followed-by one coat of primer inaccordancewith TT-P-664 or TT-P-1757 (070002- to O.001-inch thick).,.Primer shall be topcoated with two coats (each pproxirnately O.001-inch thick) .of gray enamel conforming to class 2 of PIIL-E-15090. II, ,.3.3.1.5 Glass edge finish. Corners sh

29、all be nipped, sharp edges shall be -seamed, and flares shall.“beground.flat.,.3.3.1.6 Glass edge contour. Th; contour of any edge shall not, wtinunstressed,”deviate more than 0.030inch in”a span or dist$nceof,12 inches “,3.3.1.7 Temper. Each uncoated panel”in the laminate shall have.minimumaverage

30、temper of 1800 nanometer (rim)units,”and each coated panel in the lainat,eshall have a minimum average temper of 1400 nm units. ,: .3.3.1.8 Optical and mechanical properties. Opticaland mechanical prop-erties of glass not specified herein shallbe in accordance with class 1, type Iof MIL-G-3787. ,.,

31、,.,3.3.1.9 Original luminous transmittance. The original luminous transmit-tance shall be at least 78 percent for assemblies-of overall thicknesses up to .,5/8 inch, at least 70 percent for assemblies,from 5/8 to 1-1/4 inches, and at .,;least 65 percent for Assemblies”1-1/4 to ?inches when tested as

32、 specified,in method 3022 of FI)-sTD-406using illuminant C.3.3.1.10 Resistance to delamination. When the windows are tested asspecified in 46.1,there shall be no chipping or”el,ectricalfailure, and .,.,delamination sha.Llnot be evident beyond 1 inch,fr?rnthe edge of the glass. “, ,3.3.1.11 Film, ele

33、ctricalconducting.Unless otherwise specified (see.6.2.1), the electrical conductin film shalL be applied on the,inside surface of the glass that is to be exposed to the weather. With the voltage specified(see 6.2.),the resistance value of the film shall provide awattage of 350 + 50watts per square f

34、oot for the window. Embedded sensing elements shall be loctedat control points as specified in the applicable drawing specified in 3.3.1.2.The current drawn by any single window shall not exceed 10.0 amperes (A), norbe less tan1.50 A. The desired bower dissipation and tolerance shall.be as .specifie

35、d (see 6.2.1). ,3.3.1.12 Panel terminals. Panel terminals shall consist of two braidedor stranded copper leads, soldered or otherwise securely attached to the internalbusses. , ,.3.3.,1.13 Bus construction. ,Thereshall be internal bus bars of a size,shape, and material conforming tothis specificatio

36、n which shall afford maximum .visibility. The bus bars shall he fired on the glass prior to application of5Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-M1L-w-18445D(SH)the conductive film and shall make intimate electrical contact with the film.13

37、ussesshall be inset from the edge of the panel as indicated on the applicabledrawing specified in 3.3.1.2.3.3.1.14 Continuity. When tested in accordance with 4.6.3.1, thereshall be no opens, shorts, or grounds.3.3.1.15 Electrical isolation. When tested as specified in 4.6.3.2, resultsshall indicate

38、complete electrical isolation between the sensing element and itsenvironment.3.4 Controllers. Controller shall be of steel and shall be a solid statedesign. Relays, thermostats, and mercury devices shall not be used. Controllersshall be free of defects as specified in 4.5.2. The mounting details of

39、thecontroller shall be in accordance with Drawings 805-2226902 and 805-4353964.Controller shall be “ON-OFF” type utilizing both halves of the voltage wave,and shall not impose a ground on the power system to which it is connected.3.4.1 Type I controller. Controller shall be actuated by a temperature

40、sensor embedded in the window via the junction box (see 3.3.1.4). Plastic shallnot be drilled to insert sensors.1 3.4.2 Type II controller (for retrofit use only). Controller shall beactuated by a temperature sensor contacting the inside surface of the window.Windows with a notched area shall have t

41、emperature measured in the notched area.3.4.2.1 Sensor housing. Sensor used with type II controller shall bemounted in a protective housing protruding from the back of the controller.Sensor housing shall be spring loaded against the surface of the window to pro-vide intimate thermal contact with the

42、 interior side of the glass panel.3.4.3 Controller operation. Type I and type II controllers shall beactuated by sensors and shall be capable of handling 4.4 kilowatts (kW)maximum at 440 volts root mean square (Vrms). The controller shall be operableat sensing element temperatures as low as minus 20

43、*F, shall open the circuitwhen the temperature at the sensing element reaches 90”F + 10”F, and shall closethe circuit at a sensing element temperature no greater tan 70”F. The controllershall open the circuit shollldthe following occur:I (a) Open circuit in sensing element.(b) Shorted circuit in sen

44、sing element.Operation of controller shall be tested as specified in 4.6.4.2 and 4.6.4.3. Thecontroller shall be in a steel dripproof enclosure and fitted with connectors asshown in Drawings 805-2226902 and 805-4353964. Mating connectors shall be suppliedby the contractor.I 3.4.4 Reliability. When t

45、he controllers are tested in accordance with4.6.5, the Mean Cycles Between Failure (MCBF) shall be not less than 400,000.I3.4.5 Electromagnetic interference characteristics. The electromagneticinterference characteristics of the controller shall be tested as specified in4.6.4.5.Provided by IHSNot fo

46、r ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-w-18445D(SH)3.4.6 Interchangeability. Like controllers,assemblies, subassemblies,and replaceable parts shall conform to the interchangeability requirements ofMIL-E-917 (see 4.6.6). In no case.shall parts be physically i

47、nterchangeable orreversible unless such”parts are also interchangeable or reversible with regardto function, performance and strength.3.4.7 Connectors. Ships power to the junction box ad controller shallbe by means of an electrical connector in accordance wtth MIL-C-5015. Size ofconnector shall be a

48、s shown on D7awings 805-2226902 and 805-4353964. Matingconnectors shall be furnished by the contractor. . ,3.4i$ Identification plate. Each controller shall be provided with ariidentification plate containing the manufacturers name, catalog number, NationalStock Number (NSN) (if applicable), voltage

49、, frequency, andmaximum current rat-ing. The plate shall be located on the outside of the controller. Terminalsin the controller shall be permanently and clearly marked with an identificationas to the function of each terminal. The identification plate shall comply with,the requiremetsof MIL-sT!)-130. .3.4.9 Painting. The controller”shallbe painted as specified in 3.3.1.4.3.5 Voltage. Unless otherwise s

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1