1、*USACE / NAVFAC / AFCESA / NASA UFGS-07 42 13 (May 2011)-Preparing Activity: NAVFAC SupersedingUFGS-07 42 13 (November 2010)UFGS-07 42 13 (January 2008)UFGS-07 40 00.00 40 (July 2007)UFGS-07 42 13 (April 2006)UFGS-07 46 19.00 40 (July 2007)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agr
2、eement with UMRL dated April 2011*SECTION TABLE OF CONTENTSDIVISION 07 - THERMAL AND MOISTURE PROTECTIONSECTION 07 42 13METAL WALL PANELS05/11PART 1 GENERAL1.1 REFERENCES1.2 DEFINITIONS1.3 DESCRIPTION OF WALL PANEL SYSTEM1.3.1 Metal Wall Panel General Performance1.3.2 Structural Performance1.3.3 Air
3、 Infiltration1.3.4 Water Penetration Under Static Pressure1.3.5 Water Penetration Under Dynamic Pressure1.4 SUBMITTALS1.5 QUALITY ASSURANCE1.5.1 Pre-Installation Conference1.5.1.1 Installation Drawings1.5.1.2 Wind Load Design Analysis1.5.2 Manufacturers Technical Representative1.5.3 Qualification of
4、 Manufacturer1.5.3.1 Manufacturers Certificates1.5.4 Certified Qualification of Installation Contractor1.5.4.1 Qualifications for Welding Work1.5.5 Single Source1.5.6 Manufacturers Maintenance Instructions1.6 DELIVERY, HANDLING, AND STORAGE1.7 PROJECT CONDITIONS1.7.1 Field Measurements1.7.2 Weather
5、Limitations1.8 WARRANTY1.8.1 20 Year “No Dollar Limit“ Warranty for Labor and MaterialPART 2 PRODUCTS2.1 FABRICATIONSECTION 07 42 13 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-2.1.1 Sheet Metal Accessories2.2 PANEL MATERIALS2.2.1 Aluminum
6、Sheet2.2.2 Steel Sheet2.2.3 Factory Color Finish2.2.3.1 Metal Preparation2.2.3.2 Prime Coating2.2.3.3 Exterior Finish Coating2.2.3.4 Interior Finish Coating2.2.3.5 Color2.2.3.6 Physical Properties2.3 MISCELLANEOUS METAL FRAMING2.3.1 Fasteners for Miscellaneous Metal Framing2.4 FASTENERS2.4.1 General
7、2.4.1.1 Exposed Fasteners2.4.1.2 Hidden Fasteners2.4.1.3 Screws2.4.1.4 Rivets2.4.1.5 Attachment Clips2.5 ACCESSORIES2.5.1 General2.5.2 Rubber Closure Strips2.5.3 Metal Closure Strips2.5.4 Joint Sealants2.5.4.1 Sealants and Caulking2.5.4.2 Shop-Applied2.5.4.3 Field-Applied2.5.4.4 Pressure Sensitive T
8、ape2.6 SHEET METAL FLASHING AND TRIM2.6.1 Fabrication2.7 REPAIR OF FINISH PROTECTIONPART 3 EXECUTION3.1 EXAMINATION3.2 PREPARATION3.3 WALL PANEL INSTALLATION3.3.1 Steel Wall Panels3.3.2 Aluminum Wall Panels3.3.3 Anchor Clips3.3.4 Metal Protection3.3.5 Joint Sealers3.4 FASTENER INSTALLATION3.5 FLASHI
9、NG, TRIM AND CLOSURE INSTALLATION3.5.1 General Requirements3.5.2 Metal Flashing3.5.3 Closures3.6 WORKMANSHIP3.7 ACCEPTANCE PROVISIONS3.7.1 Erection Tolerances3.7.2 Leakage Tests3.7.3 Repairs to Finish3.7.4 Paint-Finish Metal Siding3.8 FIELD QUALITY CONTROL3.8.1 Construction Monitoring3.9 CLEAN-UP AN
10、D DISPOSAL- End of Section Table of Contents -SECTION 07 42 13 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-SECTION 07 42 13 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAV
11、FAC / AFCESA / NASA UFGS-07 42 13 (May 2011)-Preparing Activity: NAVFAC SupersedingUFGS-07 42 13 (November 2010)UFGS-07 42 13 (January 2008)UFGS-07 40 00.00 40 (July 2007)UFGS-07 42 13 (April 2006)UFGS-07 46 19.00 40 (July 2007)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with
12、UMRL dated April 2011*SECTION 07 42 13METAL WALL PANELS05/11*NOTE: This guide specification covers the requirements for both factory color and mill finish aluminum or steel non-structural metal wall panels.Adhere to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard when edi
13、ting this guide specification or preparing new project specification sections. Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements
14、not required in respective project, whether or not brackets are present.Comments, suggestions and recommended changes for this guide specification are welcome and should be submitted as a Criteria Change Request (CCR).*NOTE: This section does not include light gage siding for temporary construction,
15、 housing, or pre-engineered metal buildings, or decorative wall panels.Coordinate this section with other system components specifications such as framing, insulation and sheet metal flashing. Also coordinate with applicable Unified Facilities Criteria as it relates to the specific project.*SECTION
16、07 42 13 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic desi
17、gnation only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check R
18、eference feature to update the issue dates.References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the extent
19、referenced. The publications are referred to within the text by the basic designation only.ALUMINUM ASSOCIATION (AA)AA ADM-105 (2005; Errata 2005) Aluminum Design ManualAA ASD1 (2009) Aluminum Standards and DataAMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)AAMA 501.1 (2005) Standard Test Me
20、thod for Water Penetration of Windows, Curtain Walls and Doors Using Dynamic PressureAAMA 800 (2010) Voluntary Specifications and Test Methods for SealantsAMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)ANSI/AISC 341 (2005; Suppl No. 1 2005) Seismic Provisions for Structural Steel BuildingsAMERICAN I
21、RON AND STEEL INSTITUTE (AISI)AISI S100 (2007; Supplement 1) North American Specification for the Design of Cold-Formed Steel Structural MembersAISI SG03-3 (2002; Suppl 2001-2004; R 2008) Cold-Formed Steel Design Manual SetSECTION 07 42 13 Page 5Provided by IHSNot for ResaleNo reproduction or networ
22、king permitted without license from IHS-,-,-AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE)ASCE 7-10 (2010) Minimum Design Loads for Buildings and Other StructuresAMERICAN WELDING SOCIETY (AWS)AWS A5.1/A5.1M (2004) Specification for Carbon Steel Electrodes for Shielded Metal Arc WeldingAWS D1.1/D1.1M (20
23、10) Structural Welding Code - SteelAWS D1.2/D1.2M (2008) Structural Welding Code - AluminumASTM INTERNATIONAL (ASTM)ASTM A1008/A1008M (2010) Standard Specification for Steel, Sheet, Cold-Rolled, Carbon, Structural, High-Strength Low-Alloy and High-Strength Low-Alloy with Improved Formability, Soluti
24、on Hardened, and Bake HardenedASTM A123/A123M (2009) Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel ProductsASTM A36/A36M (2008) Standard Specification for Carbon Structural SteelASTM A424/A424M (2009a) Standard Specification for Steel Sheet for Porcelain EnamelingAS
25、TM A463/A463M (2010) Standard Specification for Steel Sheet, Aluminum-Coated, by the Hot-Dip ProcessASTM A606/A606M (2009a) Standard Specification for Steel Sheet and Strip, High-Strength, Low-Alloy, Hot-Rolled and Cold-Rolled, with Improved Atmospheric Corrosion ResistanceASTM A653/A653M (2010) Sta
26、ndard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip ProcessASTM A755/A755M (2003; R 2008) Standard Specification for Steel Sheet, Metallic Coated by the Hot-Dip Process and Prepainted by the Coil-Coating Process for Exterior Exposed B
27、uilding ProductsASTM A780/A780M (2009) Standard Practice for Repair of Damaged and Uncoated Areas of Hot-Dip Galvanized CoatingsASTM A792/A792M (2010) Standard Specification for Steel Sheet, 55% Aluminum-Zinc Alloy-Coated by the Hot-Dip ProcessSECTION 07 42 13 Page 6Provided by IHSNot for ResaleNo r
28、eproduction or networking permitted without license from IHS-,-,-ASTM A924/A924M (2010a) Standard Specification for General Requirements for Steel Sheet, Metallic-Coated by the Hot-Dip ProcessASTM B 117 (2009) Standing Practice for Operating Salt Spray (Fog) ApparatusASTM B 209 (2007) Standard Speci
29、fication for Aluminum and Aluminum-Alloy Sheet and PlateASTM B 209M (2007) Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate (Metric)ASTM C 286 (1999; R 2009) Standard Terminology Relating to Porcelain Enamel and Ceramic-Metal SystemsASTM C 920 (2011) Standard Specification for
30、Elastomeric Joint SealantsASTM D 1056 (2007) Standard Specification for Flexible Cellular Materials - Sponge or Expanded RubberASTM D 1308 (2002; R 2007) Effect of Household Chemicals on Clear and Pigmented Organic FinishesASTM D 1654 (2008) Evaluation of Painted or Coated Specimens Subjected to Cor
31、rosive EnvironmentsASTM D 1667 (2005) Flexible Cellular Materials - Poly (Vinyl Chloride) Foam (Closed-Cell)ASTM D 2244 (2009b) Calculation of Color Tolerances and Color Differences from Instrumentally Measured Color CoordinatesASTM D 2247 (2010) Testing Water Resistance of Coatings in 100% Relative
32、 HumidityASTM D 2794 (1993; R 2010) Resistance of Organic Coatings to the Effects of Rapid Deformation (Impact)ASTM D 3359 (2009e2) Measuring Adhesion by Tape TestASTM D 3363 (2005) Film Hardness by Pencil TestASTM D 4214 (2007) Standard Test Method for Evaluating the Degree of Chalking of Exterior
33、Paint FilmsASTM D 4587 (2005) Standard Practice for Fluorescent UV-Condensation Exposures of Paint and Related CoatingsSECTION 07 42 13 Page 7Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-ASTM D 522 (1993a; R 2008) Mandrel Bend Test of Attached Org
34、anic CoatingsASTM D 523 (2008) Standard Test Method for Specular GlossASTM D 5894 (2010) Cyclic Salt Fog/UV Exposure of Painted Metal, (Alternating Exposures in a Fog/Dry Cabinet and a UV/Condensation Cabinet)ASTM D 610 (2008) Evaluating Degree of Rusting on Painted Steel SurfacesASTM D 714 (2002; R
35、 2009) Evaluating Degree of Blistering of PaintsASTM D 822 (2001; R 2006) Filtered Open-Flame Carbon-Arc Exposures of Paint and Related CoatingsASTM D 968 (2005; R 2010) Abrasion Resistance of Organic Coatings by Falling AbrasiveASTM E 1592 (2005) Structural Performance of Sheet Metal Roof and Sidin
36、g Systems by Uniform Static Air Pressure DifferenceASTM E 283 (2004) Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the SpecimenASTM E 331 (2000; R 2009) Water Penetration of Exterior Windows, Skylights, Doors, and C
37、urtain Walls by Uniform Static Air Pressure DifferenceASTM E 72 (2005) Conducting Strength Tests of Panels for Building ConstructionASTM E 84 (2010b) Standard Test Method for Surface Burning Characteristics of Building MaterialsASTM G 152 (2006) Operating Open Flame Carbon Arc Light Apparatus for Ex
38、posure of Nonmetallic MaterialsASTM G 153 (2004; R 2010) Operating Enclosed Carbon Arc Light Apparatus for Exposure of Nonmetallic MaterialsMETAL BUILDING MANUFACTURERS ASSOCIATION (MBMA)MBMA MBSM (2002) Metal Building Systems ManualSECTION 07 42 13 Page 8Provided by IHSNot for ResaleNo reproduction
39、 or networking permitted without license from IHS-,-,-NATIONAL ASSOCIATION OF ARCHITECTURAL METAL MANUFACTURERS (NAAMM)NAAMM AMP 500 (2006) Metal Finishes ManualPORCELAIN ENAMEL INSTITUTE (PEI)PEI 1001 (1996) Specification for Architectural Porcelain Enamel (ALS-100)PEI CG-3 (2005) Color Guide for A
40、rchitectural Porcelain EnamelSHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION (SMACNA)SMACNA 1793 (2003) Architectural Sheet Metal Manual, 6th EditionU.S. GREEN BUILDING COUNCIL (USGBC)LEED (2002; R 2005) Leadership in Energy and Environmental Design(tm) Green Building Rating System
41、 for New Construction (LEED-NC)UNDERWRITERS LABORATORIES (UL)UL Bld Mat Dir (2011) Building Materials Directory1.2 DEFINITIONSMetal Wall Panel: Metal wall panels, attachment system components and accessories necessary for a complete weather-tight wall system.1.3 DESCRIPTION OF WALL PANEL SYSTEM*NOTE
42、: Coordinate with Part 2 materials specification.In the first sentence, select finish type, metal type, attachment type and delete other options.In the second sentence, select a combination of options as necessary to describe the generic profile required. Include the last bracketed option of the sec
43、ond sentence when generic profile is shown on drawings. Show panel profile and dimensions on the drawings when a particular aesthetic appearance is desired.*Factory color finished, Mill finish galvanized galvalume aluminum metal wall panel system with concealed fastening exposed fastener attachment.
44、 Panel profile must be embossed recessed seam lock flush face smooth face recessed bead raised bead striated square ribbed beaded rib roll lock seam snap lock seam box rib corrugated standing seam batten seam and with stiffening ribs in the flat of the panel as shown on drawings.SECTION 07 42 13 Pag
45、e 9Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-1.3.1 Metal Wall Panel General PerformanceComply with performance requirements, conforming to AISI S100, without failure due to defective manufacture, fabrication, installation, or other defects in construction. Wall panels and accessory components must conform to the following standards:ASTM A1008/A1008MASTM A123/A123MASTM A36