1、*USACE / NAVFAC / AFCESA UFGS-08 14 00 (August 2011)-Preparing Activity: NAVFAC SupersedingUFGS-08 14 00 (May 2011)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2011*SECTION TABLE OF CONTENTSDIVISION 08 - OPENINGSSECTION 08 14 00WOOD DOORS08/11PART 1 GENERAL

2、1.1 REFERENCES1.2 SUBMITTALS1.3 SUSTAINABLE DESIGN CERTIFICATION/DOCUMENTATION1.4 LOCAL/REGIONAL MATERIALS1.5 DELIVERY, STORAGE, AND HANDLING1.6 WARRANTYPART 2 PRODUCTS2.1 DOORS2.1.1 Stile and Rail Doors2.1.2 Flush Doors2.1.2.1 Exterior Flush Doors2.1.2.2 Interior Flush Doors2.1.3 Bi-Fold Closet Doo

3、rs2.1.4 Sliding Closet Doors2.1.5 X-Ray Resistant Doors2.1.6 Acoustical Doors2.1.7 Composite-Type Fire Doors2.1.8 Prehung Doors2.2 ACCESSORIES2.2.1 Door Louvers2.2.2 Door Light Openings2.2.3 Weatherstripping2.2.4 Additional Hardware Reinforcement2.3 FABRICATION2.3.1 Marking2.3.2 Quality and Construc

4、tion2.3.3 Preservative Treatment2.3.4 Adhesives and Bonds2.3.5 Prefitting2.3.6 Finishes2.3.6.1 Field Painting2.3.6.2 Factory Finish2.3.6.3 Plastic Laminate FinishSECTION 08 14 00 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-2.3.6.4 Color2.3.

5、7 Water-Resistant Sealer2.4 SOURCE QUALITY CONTROLPART 3 EXECUTION3.1 INSTALLATION3.1.1 Fire and Smoke Doors3.1.2 Prehung Doors3.1.3 Weatherstripping3.2 SCHEDULE- End of Section Table of Contents -SECTION 08 14 00 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without lic

6、ense from IHS-,-,-*USACE / NAVFAC / AFCESA UFGS-08 14 00 (August 2011)-Preparing Activity: NAVFAC SupersedingUFGS-08 14 00 (May 2011)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2011*SECTION 08 14 00WOOD DOORS08/11*NOTE: This guide specification covers requ

7、irements for wood doors.Adhere to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard when editing this guide specification or preparing new project specification sections. Edit this guide specification for project specific requirements by adding, deleting, or revising text.

8、For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments, suggestions and recommended changes for this guide specification are welcome and should be submitted

9、 as a Criteria Change Request (CCR).*NOTE: On the drawings, show:1. Locations2. Sizes, types, thicknesses, glazing, and louvers3. Designs4. Fire rating requirements5. Color6. Door swing7. Sound transmission class.*SECTION 08 14 00 Page 3Provided by IHSNot for ResaleNo reproduction or networking perm

10、itted without license from IHS-,-,-PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date,

11、and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to update the issue dates.References not used in the text wil

12、l automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by the basic designat

13、ion only.ARCHITECTURAL WOODWORK INSTITUTE (AWI)AWI Qual Stds (8th Edition) AWI Quality StandardsASTM INTERNATIONAL (ASTM)ASTM E 283 (2004) Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the SpecimenASTM E 90 (2009) S

14、tandard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and ElementsASTM E2226 (2010; E 2011) Standard Practice for Application of Hose StreamGREENGUARD ENVIRONMENTAL INSTITUTE (GEI)GEI Greenguard Standards for Low Emitting ProductsNATIONAL ELECTRICA

15、L MANUFACTURERS ASSOCIATION (NEMA)ANSI/NEMA LD 3 (2005) Standard for High-Pressure Decorative LaminatesSECTION 08 14 00 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)NFPA 105 (2010) Standard for Inst

16、allation of Smoke Door Assemblies and Other Opening ProtectivesNFPA 252 (2008) Standard Methods of Fire Tests of Door AssembliesNFPA 80 (2010; TIA 10-2) Standard for Fire Doors and Other Opening ProtectivesSCIENTIFIC CERTIFICATION SYSTEMS (SCS)SCS Scientific Certification Systems (SCS)Indoor Advanta

17、geU.S. GREEN BUILDING COUNCIL (USGBC)LEED (2002; R 2005) Leadership in Energy and Environmental Design(tm) Green Building Rating System for New Construction (LEED-NC)LEED Reference Guide (2005) LEED-NC Reference Guide for New ConstructionUNDERWRITERS LABORATORIES (UL)UL 10B (2008; Reprint Apr 2009)

18、Fire Tests of Door AssembliesWINDOW AND DOOR MANUFACTURERS ASSOCIATION (WDMA)WDMA I.S. 1-A (2007) Architectural Wood Flush DoorsWDMA I.S. 4 (2009) Water-Repellent Preservative Non-Pressure Treatment for MillworkWDMA I.S. 6 (2008) Wood Stile and Rail DoorsWDMA TM-7 (2008) Cycle Slam Test MethodWDMA T

19、M-8 (2008) Hinge Loading Test Method1.2 SUBMITTALS*NOTE: Where a “G“ in submittal tags follows a submittal item, it indicates Government approval for that item. Add “G“ in submittal tags following any added or existing submittal items deemed sufficiently critical, complex, or aesthetically significa

20、ntly to merit approval by the Government. Submittal items not designated with a “G“ will be approved by the QC organization.*Submit the following in accordance with Section 01 33 00 SUBMITTAL SECTION 08 14 00 Page 5Provided by IHSNot for ResaleNo reproduction or networking permitted without license

21、from IHS-,-,-PROCEDURES.SD-02 Shop DrawingsDoors; G; G, _Submit drawings or catalog data showing each type of door unit ; descriptive data of head and jamb weatherstripping with installation instructions shall be included. Drawings and data shall indicate door type and construction, sizes, thickness

22、, methods of assembly, door louvers, and glazing,.SD-03 Product DataDoors; G; G, _AccessoriesWater-resistant sealerSample warrantySound transmission class rating; G; G, _Fire resistance rating; G; G, _CertificationLocal/Regional Materials; (LEED)LEED documentation relative to local/regional material

23、s credit in accordance with LEED Reference Guide. Include in LEED Documentation Notebook.SD-04 Samples*NOTE: Require door samples only for relatively larger quantities of doors and only when justified and desired.*DoorsPrior to the delivery of wood doors, submit a sample section of each type of door

24、 which shows the stile, rail, veneer, finish, and core construction.Door finish colors; G; G, _Submit a minimum of three color selection samples , minimum 76 by 127 mm 3 by 5 inches in size representing wood stain for selection by the Contracting Officer.SD-06 Test Reports*NOTE: Require tests and te

25、st reports when fire SECTION 08 14 00 Page 6Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-rated wood doors are included in the project. Doors designated to have “C“ label have a 3/4 hour rating, doors designated to have “B“ label have a one or 1 1/

26、2 hour rating.*Cycle-slamHinge loading resistanceSubmit cycle-slam test report for doors tested in accordance with WDMA TM-7, and hinge loading resistance test report for doors tested in accordance with WDMA TM-8.1.3 SUSTAINABLE DESIGN CERTIFICATION/DOCUMENTATIONProduct shall be third party certifie

27、d by GEI Greenguard Indoor Air Quality Certified, SCS Scientific Certification Systems Indoor Advantage or equal. Certification shall be performed annually and shall be current.1.4 LOCAL/REGIONAL MATERIALSUse products extracted, harvested, or recovered, as well as manufactured, within a 500 mile rad

28、ius from the project site, if available from a minimum of three sources. Refer to Section 01 33 29 LEED DOCUMENTATION for cumulative total local material requirements. Wood doors may be locally available.1.5 DELIVERY, STORAGE, AND HANDLINGDeliver doors to the site in an undamaged condition and prote

29、ct against damage and dampness. Stack doors flat under cover. Support on blocking, a minimum of 100 mm 4 inch thick, located at each end and at the midpoint of the door. Store doors in a well-ventilated building so that they will not be exposed to excessive moisture, heat, dryness, direct sunlight,

30、or extreme changes of temperature and humidity. Do not store in a building under construction until concrete, masonry work, and plaster are dry. Replace defective or damaged doors with new ones.1.6 WARRANTY*NOTE: The warranty clause in this guide specification has been approved by NAVFACENGCOMHQ in

31、accordance with the requirements of Naval Facilities Acquisition Supplement (NFAS). NFAS can be found at the following link:https:/portal.navfac.navy.mil/portal/page/portal/navfac/navfac_forbusinesses_The paragraph in this guide specification may be used without any other HQ approval or request for

32、waiver.*Warrant doors free of defects as set forth in the door manufacturers standard door warranty.SECTION 08 14 00 Page 7Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-PART 2 PRODUCTS2.1 DOORS*NOTE: It is preferred that door sizes, designs and thi

33、cknesses be indicated on the drawings; if not indicated, schedule appropriate criteria in specifications. Refer to WDMA I.S. 1-A and WDMA I.S. 6 for stock sizes and designs; the use of stock doors is recommended.*NOTE: Include requirements for wood frames, except for prehung interior wood door units

34、, in Section 06 20 00 FINISH CARPENTRY. Include requirements for metal frames for wood doors in Section 08 11 13 STEEL DOORS AND FRAMES. Include requirements for hardware, other than for sliding and bi-fold doors, in Section 08 71 00 DOOR HARDWARE.*NOTE: Premium or select grade is intended for natur

35、al or stain finish, standard grade is intended for opaque (paint) finish.*Provide doors of the types, sizes, and designs indicated specified free of urea-formaldehyde resins.2.1.1 Stile and Rail DoorsPremium Standard grade Ponderosa Pine doors or premium or select standard stile and rail doors confo

36、rming to WDMA I.S. 6. Furnish laminate panels in not less than three ply thickness. Provide flat panels with a minimum finished panel thickness of 13 mm 1/2 inch and 20 mm 3/4 inchthickness for raised panels.2.1.2 Flush DoorsConform to WDMA I.S. 1-A for flush doors. Provide hollow core doors with lo

37、ck blocks and 25 mm 1 inch minimum thickness hinge stile. Hardwood stile edge bands of doors receives a natural finish, compatible with face veneer. Provide mill option for stile edge of doors scheduled to be painted. No visible finger joints will be accepted in stile edge bands. When used, locate f

38、inger-joints under hardware.2.1.2.1 Exterior Flush Doors*NOTE: Use of wood doors on exterior of buildings is not recommended for permanent structures unless the doors are well protected from the weather.*Solid wood core, Type I conforming to WDMA I.S. 1-A. Provide doors with tempered hardboard mediu

39、m density overlayed hardwood veneer faces. SECTION 08 14 00 Page 8Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Provide wood edge bands. Install in exterior flush doors with aluminum bronze copper flashings at the bottom of the openings.2.1.2.2 Int

40、erior Flush Doors*NOTE: Hollow core doors should be used for light duty residential only. Face veneers of doors for painted finish should be either hardboard or sound grade rotary cut hardwood. Face veneers of doors for natural finish should be premium or good grade rotary cut hardwood. Premium grad

41、e, book matched, wood veneer should only be specified for medical facilities and other high quality installations such as chapels, hospitals, and where the additional cost is justified. Select grade and species desired for hardwood veneer faced doors. Specify other veneers if desired (poplar, cherry, etc.); refer to WDMA I.S. 1-A. Luan is not acceptable.*NOTE: Consider the use of agrifiber