NAVY UFGS-08 32 13-2008 ALUMINUM SLIDING GLASS DOORS《铝制滑动玻璃门》.pdf

上传人:fuellot230 文档编号:984736 上传时间:2019-03-12 格式:PDF 页数:10 大小:50.29KB
下载 相关 举报
NAVY UFGS-08 32 13-2008 ALUMINUM SLIDING GLASS DOORS《铝制滑动玻璃门》.pdf_第1页
第1页 / 共10页
NAVY UFGS-08 32 13-2008 ALUMINUM SLIDING GLASS DOORS《铝制滑动玻璃门》.pdf_第2页
第2页 / 共10页
NAVY UFGS-08 32 13-2008 ALUMINUM SLIDING GLASS DOORS《铝制滑动玻璃门》.pdf_第3页
第3页 / 共10页
NAVY UFGS-08 32 13-2008 ALUMINUM SLIDING GLASS DOORS《铝制滑动玻璃门》.pdf_第4页
第4页 / 共10页
NAVY UFGS-08 32 13-2008 ALUMINUM SLIDING GLASS DOORS《铝制滑动玻璃门》.pdf_第5页
第5页 / 共10页
点击查看更多>>
资源描述

1、*USACE / NAVFAC / AFCESA / NASA UFGS-08 32 13 (November 2008)-Preparing Activity: NAVFAC Superseding UFGS-08 32 13 (April 2006)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated October 2008*SECTION TABLE OF CONTENTSDIVISION 08 - OPENINGSSECTION 08 32 13ALUMINUM SLIDI

2、NG GLASS DOORS11/08PART 1 GENERAL1.1 REFERENCES1.2 SUBMITTALS1.3 TEMPORARY PROTECTIVE COVERING1.4 DELIVERY AND STORAGE1.5 EXTRA STOCKPART 2 PRODUCTS2.1 ALUMINUM SLIDING GLASS DOORS2.1.1 Hardware2.1.2 Glazing2.1.3 Weatherstripping2.1.4 Screens2.1.5 Finish2.2 CALKING AND SEALING2.3 FORCED ENTRY RESIST

3、ANT DOORSPART 3 EXECUTION3.1 INSTALLATION3.1.1 Doors, Frames, and Accessories3.1.2 Protection of Aluminum from Dissimilar Materials3.1.2.1 Aluminum to Dissimilar Metals3.1.2.2 Drainage from Dissimilar Metals3.1.2.3 Aluminum to Masonry and Concrete3.1.2.4 Aluminum to Wood- End of Section Table of Con

4、tents -SECTION 08 32 13 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-08 32 13 (November 2008)-Preparing Activity: NAVFAC Superseding UFGS-08 32 13 (April 2006)UNIFIED FACILITIES GUIDE SPECIFICATIONSRefere

5、nces are in agreement with UMRL dated October 2008*SECTION 08 32 13ALUMINUM SLIDING GLASS DOORS11/08*NOTE: This guide specification covers the requirements for aluminum sliding glass doors for commercial, residential, and monumental type buildings.Edit this guide specification for project specific r

6、equirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments and suggestions on this guide specification are we

7、lcome and should be directed to the technical proponent of the specification. A listing of technical proponents, including their organization designation and telephone number, is on the Internet.Recommended changes to a UFGS should be submitted as a Criteria Change Request (CCR).*NOTE: Aluminum slid

8、ing glass doors are intended for use as an entrance to a patio, terraced area, or balcony, where only primary conventional door exits are available for use from the same interior area. Sliding glass doors shall not be the only exit from public use areas.*NOTE: On the drawings show opening sizes and

9、schedule, arrangement of fixed and sliding panels, and methods of anchoring frames.*SECTION 08 32 13 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the

10、 text of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automa

11、tically place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to update the issue dates.References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish p

12、rint process.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.ALUMINUM ASSOCIATION (AA)AA DAF-45 (2003) Designation System for Aluminum FinishesAMERICAN ARCHITECTURAL MANUFACTURER

13、S ASSOCIATION (AAMA)AAMA 101 (2005) Standard Specification for Windows, Doors, and Unit SkylightsAAMA 1503 (1998) Voluntary Test Method for Thermal Transmittance and Condensation Resistance of Windows, Doors and Glazed Wall SectionsAAMA 800 (2005) Voluntary Specifications and Test Methods for Sealan

14、tsASTM INTERNATIONAL (ASTM)ASTM C 1048 (2004) Standard Specification for Heat-Treated Flat Glass - Kind HS, Kind FT Coated and Uncoated GlassASTM D 3656 (2007) Insect Screening and Louver Cloth Woven from Vinyl-Coated Glass YarnsASTM E 2016 (2006) Standard Specification for Industrial Woven Wire Clo

15、thASTM F 842 (2004) Measuring the Forced Entry SECTION 08 32 13 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Resistance of Sliding Door Assemblies, Excluding Glazing ImpactU.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)16 CFR 1201 S

16、afety Standard for Architectural Glazing Materials1.2 SUBMITTALS*NOTE: Review submittal description (SD) definitions in Section 01 33 00 SUBMITTAL PROCEDURES and edit the following list to reflect only the submittals required for the project. Submittals should be kept to the minimum required for ade

17、quate quality control.A “G” following a submittal item indicates that the submittal requires Government approval. Some submittals are already marked with a “G”. Only delete an existing “G” if the submittal item is not complex and can be reviewed through the Contractors Quality Control system. Only a

18、dd a “G” if the submittal is sufficiently important or complex in context of the project.For submittals requiring Government approval on Army projects, a code of up to three characters within the submittal tags may be used following the “G“ designation to indicate the approving authority. Codes for

19、Army projects using the Resident Management System (RMS) are: “AE“ for Architect-Engineer; “DO“ for District Office (Engineering Division or other organization in the District Office); “AO“ for Area Office; “RO“ for Resident Office; and “PO“ for Project Office. Codes following the “G“ typically are

20、not used for Navy, Air Force, and NASA projects.Choose the first bracketed item for Navy, Air Force and NASA projects, or choose the second bracketed item for Army projects.*Government approval is required for submittals with a “G“ designation; submittals not having a “G“ designation are for Contrac

21、tor Quality Control approval.for information only. When used, a designation following the “G“ designation identifies the office that will review the submittal for the Government. The following shall be submitted in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:SD-02 Shop Drawings*NOTE: Selec

22、t this paragraph or the paragraph entitled “Manufacturers Catalog Data“ based on which is appropriate for the project. Both paragraphs may be used if necessary.*SECTION 08 32 13 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Aluminum sliding g

23、lass doorsSubmit drawings for aluminum sliding glass doors , screens, and accessories that indicate elevations of each door type, full size sections, thickness, nominal gages of metal, fastenings, proposed method of installation and anchoring, the size and spacing and method of glazing, details of o

24、perating hardware, method and material for weatherstripping, type of finish, and screen details.SD-03 Product Data*NOTE: Select this paragraph or paragraph entitled “Drawings“ based on which is appropriate for the project. Both may be used if necessary.*Aluminum sliding glass doorsHardwareGlazingWea

25、therstrippingScreensFinishDescribe each type of aluminum sliding glass door, hardware, fastener, accessory, screen, and finish. Include descriptive literature, detailed specifications, and performance test data.SD-04 SamplesFinishSubmit color chart of factory color coatings when factory-finished col

26、or coating is to be provided.SD-10 Operation and Maintenance DataAluminum sliding glass doors, Data Package 1; ; G; G, _Submit in accordance with Section 01 78 23 OPERATION AND MAINTENANCE DATA.1.3 TEMPORARY PROTECTIVE COVERING*NOTE: The protection specified in this paragraph is a temporary protecti

27、on for doors to be installed during construction of new buildings. The paragraph may be deleted when specifying doors for existing building construction.*SECTION 08 32 13 Page 5Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Prior to shipment from th

28、e factory, finished surfaces of aluminum sliding glass doors shall receive a protective covering of waterproof tape, strippable plastic, or cardboard to protect against discoloration and surface damage that may occur during transportation, storage, and construction activities. Also, no coatings or l

29、acquers shall be applied to surfaces to which calking and glazing compounds must adhere. Covering shall be readily removable after installation.1.4 DELIVERY AND STORAGEInspect aluminum sliding glass doors, including screens, hardware and accessories, for damage and unload and store doors upright on

30、platforms in accessible spaces with a minimum of handling. The storage spaces shall be dry, adequately ventilated, free from heavy dust and not subject to combustion products, sources of water or other conditions that could damage the door. Storage spaces shall have easy access for inspection and ha

31、ndling of doors.1.5 EXTRA STOCKDeliver an extra stock of markings for glass panels to the Government for use in future replacement of original markings. The extra stock shall be of the same designs, colors, and materials as the markings installed on this project. Furnish markings in original contain

32、ers or packages in a quantity not less than _ percent of the amount of markings to be installed.PART 2 PRODUCTS2.1 ALUMINUM SLIDING GLASS DOORS*NOTE: Aluminum sliding glass doors (SDG) designation and type in AAMA 101 establishes a minimum Performance Class for each door Grade: 15 for residential (R

33、) 20 for commercial (C); and 40 for heavy commercial (HC). Units installed in high wind zones should be specified in accordance with the recommendation in AAMA 101.*NOTE: For minimum cost, use stock designs in standard sizes where possible. Require only minimum changes to standard design, and use mi

34、nimum number of different sizes. Vinyl safety markings should be used where appropriate to make personnel aware of glass. If specific designs and colors are required for markings, indicate on the drawings; in monumental installation, a horizontal muntin may be specified or indicated.*Design and cons

35、truct with sliding panels and fixed panels in the sizes and arrangements indicated and conforming to AAMA 101 for Type SGD-R15 SGD-C20 SGD-HC40, SGD-_ except frame shall be equipped with thermal barrier. Mark panels identically and permanently to visibly interrupt the span of glass. Use markings of

36、the design and color indicated approximately 2500 square millimeters (mm) 4 square inches of SECTION 08 32 13 Page 6Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-opaque, pressure-sensitive vinyl film with precoated adhesive. Sliding door glazing sh

37、all be set in aluminum frames and roller assemblies of sufficient strength to withstand lateral live stresses and static load or weight requirements.2.1.1 Hardware*NOTE: Key-operated cylinders may be incorporated into a master keying system provided they are: (1) manufactured by the same manufacture

38、r as the manufacturer of the locks for the other doors, and (2) the number of pin tumblers in the cylinder for the sliding glass door locks is the same as the number of pin tumblers provided in the cylinders of the locks for the other doors.*Sliding door panel shall have a manually operated adjustab

39、le latch operable by latch handle or slide bar from inside only operable by a five-pin tumbler cylinder lock on outside and thumb-turn on the inside operable by a five-pin tumbler cylinder lock from either side. Fit sliding screen door panel with a self-latching hook or rotary-type latch operable fr

40、om inside only both sides. Provide pulls for both inside and outside of sliding panel and the sliding screen panel. Provide a pull on the inside of the sliding door panel and the sliding screen panel only. Provide auxiliary pin lock bottom top and bottom on inner side of sliding glass door panel opp

41、osite manually operated adjustable latch. Exposed hardware is to be aluminum or stainless steel, color finished to match door color finish.2.1.2 Glazing*NOTE: Select the thickness of glass using the Glass Table provided in AAMA 101. Glass thickness shall be not less than 6 mm 1/4 inch. Double glazing shall be used in cold climates to minimize heat loss and conserve fuel. The Condensation Resistant Factor should be specified in accordance with the recommendation in AAMA 1503.*Factory glazed sliding glass doors, including fixed panel, with single glazed double-glazed

展开阅读全文
相关资源
猜你喜欢
  • DIN 1306-1984 Density concepts presentation of values《密度;概念、量值表示方法》.pdf DIN 1306-1984 Density concepts presentation of values《密度;概念、量值表示方法》.pdf
  • DIN 13073-2016 Rescue systems - Dimensions for maintain systems for fastening of undercarriage and stretcher in ambulances《营救设备 救护车中起落架和担架紧固用维护设备的尺寸》.pdf DIN 13073-2016 Rescue systems - Dimensions for maintain systems for fastening of undercarriage and stretcher in ambulances《营救设备 救护车中起落架和担架紧固用维护设备的尺寸》.pdf
  • DIN 13080 Bb 3-2016 Division of hospitals into functional areas and functional sections - Form for the determination of areas in hospitals《按职能范围和功能部门划分的医院分部 确定医院分布面积用表格》.pdf DIN 13080 Bb 3-2016 Division of hospitals into functional areas and functional sections - Form for the determination of areas in hospitals《按职能范围和功能部门划分的医院分部 确定医院分布面积用表格》.pdf
  • DIN 13080 Bb 4-2016 Division of hospitals into functional areas and functional sections - Masterplanning for general hospitals《将医院按功能分成区域和部门 普通医院的总体规划》.pdf DIN 13080 Bb 4-2016 Division of hospitals into functional areas and functional sections - Masterplanning for general hospitals《将医院按功能分成区域和部门 普通医院的总体规划》.pdf
  • DIN 13080-2016 Division of hospitals into functional areas and functional sections《按职能范围和职能分类划分的医院》.pdf DIN 13080-2016 Division of hospitals into functional areas and functional sections《按职能范围和职能分类划分的医院》.pdf
  • DIN 13086-2005 External introducer cannulae for suprapubic catheter systems for single use - Requirements and testing《一次性趾骨弓上导管系统用外部导入套管 要求和试验》.pdf DIN 13086-2005 External introducer cannulae for suprapubic catheter systems for single use - Requirements and testing《一次性趾骨弓上导管系统用外部导入套管 要求和试验》.pdf
  • DIN 13090-4-1986 Conical fittings for medical equipment lock fittings for resectoscopes《医疗器械用锥形接头 (经尿道前列腺)切除器用锁紧接头》.pdf DIN 13090-4-1986 Conical fittings for medical equipment lock fittings for resectoscopes《医疗器械用锥形接头 (经尿道前列腺)切除器用锁紧接头》.pdf
  • DIN 13093-2017 Screening test for nickel release from consumer articles which are inserted into pierced parts of the human body and consumer articles that come into direct and prol.pdf DIN 13093-2017 Screening test for nickel release from consumer articles which are inserted into pierced parts of the human body and consumer articles that come into direct and prol.pdf
  • DIN 13097-4-2009 Hypodermic needles - Part 4 Point geometry requirements and testing《皮下注射针 第4部分》.pdf DIN 13097-4-2009 Hypodermic needles - Part 4 Point geometry requirements and testing《皮下注射针 第4部分》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1