1、*USACE / NAVFAC / AFCESA / NASA UFGS-08 81 00 (August 2011)-Preparing Activity: NAVFAC SupersedingUFGS-08 81 00 (February 2011)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2011*SECTION TABLE OF CONTENTSDIVISION 08 - OPENINGSSECTION 08 81 00GLAZING08/11PART
2、1 GENERAL1.1 REFERENCES1.2 SUBMITTALS1.3 SYSTEM DESCRIPTION1.4 DELIVERY, STORAGE, AND HANDLING1.5 ENVIRONMENTAL REQUIREMENTS1.6 SUSTAINABLE DESIGN REQUIREMENTS1.6.1 Local/Regional Materials1.6.2 Environmental Data1.7 WARRANTY1.7.1 Warranty for Insulating Glass Units1.7.2 Warranty for Polycarbonate S
3、heet1.7.3 Monolithic Reflective Glass1.7.4 Monolithic Opacified SpandrelPART 2 PRODUCTS2.1 GLASS2.1.1 Clear Glass2.1.2 Annealed Glass2.1.3 Heat-Absorbing Glass2.1.4 Wired Glass2.1.5 Patterned Glass2.1.6 Laminated Glass2.1.7 Bullet-Resisting Glass2.1.8 Mirrors2.1.8.1 Glass Mirrors2.1.9 One-Way Vision
4、 Glass (Transparent Mirrors)2.1.10 Tempered Glass2.1.11 Heat-Strengthened Glass2.1.12 Spandrel Glass2.1.12.1 Ceramic-Opacified Spandrel Glass2.1.12.2 Film-Opacified Spandrel Glass2.1.12.3 Spandrel Glass With Adhered Backing2.1.13 Fire/Safety Rated GlassSECTION 08 81 00 Page 1Provided by IHSNot for R
5、esaleNo reproduction or networking permitted without license from IHS-,-,-2.1.14 Tinted (Light-Reducing) Glass2.2 INSULATING GLASS UNITS2.2.1 Buildings2.2.2 Control Towers2.2.2.1 Control Tower Insulating Glass2.2.2.2 Control Tower Heat-Absorbing Insulating Glass2.2.2.3 Control Tower Clear Insulating
6、 Glass2.2.2.4 Control Tower Laminated Glass2.2.3 Low Emissivity Insulating Glass2.3 PLASTIC GLAZING2.3.1 Acrylic Sheet2.3.2 Polycarbonate Sheet2.3.3 Extruded Polycarbonate Profiled Sheet2.3.4 Bullet-Resistant Plastic Sheet2.4 SETTING AND SEALING MATERIALS2.4.1 Putty and Glazing Compound2.4.2 Glazing
7、 Compound2.4.3 Sealants2.4.3.1 Elastomeric Sealant2.4.3.2 Structural Sealant2.4.4 Joint Backer2.4.5 Preformed Channels2.4.6 Sealing Tapes2.4.7 Setting Blocks and Edge Blocks2.4.8 Glazing Gaskets2.4.8.1 Fixed Glazing Gaskets2.4.8.2 Wedge Glazing Gaskets2.4.8.3 Aluminum Framing Glazing Gaskets2.4.9 Ac
8、cessories2.5 MIRROR ACCESSORIES2.5.1 Mastic2.5.2 Mirror Frames2.5.3 Mirror ClipsPART 3 EXECUTION3.1 PREPARATION3.2 GLASS SETTING3.2.1 Sheet Glass3.2.2 Patterned Glass3.2.3 Insulating Glass Units3.2.4 Installation of Wire Glass3.2.5 Installation of Heat-Absorbing Glass3.2.6 Installation of Laminated
9、Glass3.2.7 Plastic Sheet3.3 ADDITIONAL REQUIREMENTS FOR GLAZING CONTROL TOWER WINDOWS3.3.1 Materials and Methods of Installation3.3.2 Tolerances and Clearances of Units3.4 CLEANING3.5 PROTECTION3.6 WASTE MANAGEMENT3.7 SCHEDULE- End of Section Table of Contents -SECTION 08 81 00 Page 2Provided by IHS
10、Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-08 81 00 (August 2011)-Preparing Activity: NAVFAC SupersedingUFGS-08 81 00 (February 2011)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 20
11、11*SECTION 08 81 00GLAZING08/11*NOTE: This guide specification covers the requirements for normal glazing.Adhere to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard when editing this guide specification or preparing new project specification sections. Edit this guide speci
12、fication for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments, suggestions and re
13、commended changes for this guide specification are welcome and should be submitted as a Criteria Change Request (CCR).*NOTE: If special glazing such as leaded glass, laminated transparent mirrors, or plastic glazing for unprotected openings is required, add appropriate paragraphs.*NOTE: TO DOWNLOAD
14、UFGS GRAPHICSGo to http:/www.wbdg.org/ccb/NAVGRAPH/graphtoc.pdf.*NOTE: On the drawings, show:1. Locations of each type of glass, using same terminology as in specification.2. Thickness of glass, unless glass of each type is SECTION 08 81 00 Page 3Provided by IHSNot for ResaleNo reproduction or netwo
15、rking permitted without license from IHS-,-,-same thickness.3. Frame and rabbet details, indicating method of glazing.*PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basi
16、c designation only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards C
17、heck Reference feature to update the issue dates.References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the e
18、xtent referenced. The publications are referred to within the text by the basic designation only.AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)ANSI Z97.1 (2009; Errata 2010) Safety Glazing Materials Used in Buildings - Safety Performance Specifications and Methods of TestAMERICAN SOCIETY OF CIVIL ENGI
19、NEERS (ASCE)ASCE 7-10 (2010; Change 2010; Change 2011) Minimum Design Loads for Buildings and Other StructuresASTM INTERNATIONAL (ASTM)ASTM C1036 (2006) Standard Specification for Flat GlassASTM C1048 (2004) Standard Specification for Heat-Treated Flat Glass - Kind HS, Kind FT Coated and Uncoated Gl
20、assASTM C1172 (2009e1) Standard Specification for Laminated Architectural Flat GlassSECTION 08 81 00 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-ASTM C1184 (2005) Standard Specification for Structural Silicone SealantsASTM C509 (2006; R 201
21、1) Elastomeric Cellular Preformed Gasket and Sealing MaterialASTM C864 (2005; R 2011) Dense Elastomeric Compression Seal Gaskets, Setting Blocks, and SpacersASTM C920 (2011) Standard Specification for Elastomeric Joint SealantsASTM D 2287 (1996; R 2010) Nonrigid Vinyl Chloride Polymer and Copolymer
22、Molding and Extrusion CompoundsASTM D 395 (2003; R 2008) Standard Test Methods for Rubber Property - Compression SetASTM D 4802 (2010) Poly(Methyl Methacrylate) Acrylic Plastic SheetASTM E 119 (2011) Standard Test Methods for Fire Tests of Building Construction and MaterialsASTM E 1300 (2009a) Deter
23、mining Load Resistance of Glass in BuildingsASTM E 2129 (2005) Standard Practice for Data Collection for Sustainability Assessment of Building ProductsASTM E 413 (2010) Rating Sound InsulationASTM E 90 (2009) Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Buil
24、ding Partitions and ElementsASTM E2226 (2010; E 2011) Standard Practice for Application of Hose StreamGLASS ASSOCIATION OF NORTH AMERICA (GANA)GANA Glazing Manual (2004) Glazing ManualGANA Sealant Manual (2008) Sealant ManualGANA Standards Manual (2001) Tempering Divisions Engineering Standards Manu
25、alINSULATING GLASS MANUFACTURERS ALLIANCE (IGMA)IGMA TB-3001 (1990) Guidelines for Sloped GlazingIGMA TM-3000 (1997) Glazing Guidelines for Sealed Insulating Glass UnitsSECTION 08 81 00 Page 5Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-IGMA TR-12
26、00 (1983) Commercial Insulating Glass Dimensional TolerancesNATIONAL FENESTRATION RATING COUNCIL (NFRC)NFRC 100 (2010) Procedure for Determining Fenestration Product U-FactorsNFRC 200 (2010) Procedure for Determining Fenestration Product Solar Heat Gain Coefficient and Visible Transmittance at Norma
27、l IncidenceNATIONAL FIRE PROTECTION ASSOCIATION (NFPA)NFPA 252 (2008) Standard Methods of Fire Tests of Door AssembliesNFPA 257 (2007) Standard on Fire Test for Window and Glass Block AssembliesNFPA 80 (2010; TIA 10-2) Standard for Fire Doors and Other Opening ProtectivesU.S. ENVIRONMENTAL PROTECTIO
28、N AGENCY (EPA)Energy Star (1992; R 2006) Energy Star Energy Efficiency Labeling SystemU.S. GREEN BUILDING COUNCIL (USGBC)LEED (2002; R 2005) Leadership in Energy and Environmental Design(tm) Green Building Rating System for New Construction (LEED-NC)U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION
29、(NARA)16 CFR 1201 Safety Standard for Architectural Glazing MaterialsUNDERWRITERS LABORATORIES (UL)UL 752 (2005; Reprint Jul 2011) Standard for Bullet-Resisting EquipmentUL MEAPD (2003) Mechanical Equipment and Associated Products Directory (online version is listed under Certifications at )1.2 SUBM
30、ITTALS*NOTE: Review submittal description (SD) definitions in Section 01 33 00 SUBMITTAL PROCEDURES and edit the following list to reflect only the submittals required for the project. Submittals should be kept to the minimum required for adequate quality control.SECTION 08 81 00 Page 6Provided by I
31、HSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A “G” following a submittal item indicates that the submittal requires Government approval. Some submittals are already marked with a “G”. Only delete an existing “G” if the submittal item is not complex and can be
32、reviewed through the Contractors Quality Control system. Only add a “G” if the submittal is sufficiently important or complex in context of the project.For submittals requiring Government approval on Army projects, a code of up to three characters within the submittal tags may be used following the
33、“G“ designation to indicate the approving authority. Codes for Army projects using the Resident Management System (RMS) are: “AE“ for Architect-Engineer; “DO“ for District Office (Engineering Division or other organization in the District Office); “AO“ for Area Office; “RO“ for Resident Office; and
34、“PO“ for Project Office. Codes following the “G“ typically are not used for Navy, Air Force, and NASA projects.Choose the first bracketed item for Navy, Air Force and NASA projects, or choose the second bracketed item for Army projects.*Government approval is required for submittals with a “G“ desig
35、nation; submittals not having a “G“ designation are for Contractor Quality Control approval.for information only. When used, a designation following the “G“ designation identifies the office that will review the submittal for the Government. The following shall be submitted in accordance with Sectio
36、n 01 33 00 SUBMITTAL PROCEDURES:SD-02 Shop DrawingsInstallationDrawings showing complete details of the proposed setting methods, mullion details, edge blocking, size of openings, frame details, materials, and types and thickness of glass. Control Tower Insulating Glass Control Tower Laminated Glass
37、Drawings showing complete details of the proposed setting methods, mullion details, edge blocking, size of openings, frame details, materials, and types and thickness of glass.*NOTE: Regarding the use of SD-03 Product Data and SD-07 Certificates, only use one of these on complicated and large produc
38、ts. It is preferred to use SD-03 Product Data. If control tower glazing data is only available by certificates, use SD-07 Certificates.*SECTION 08 81 00 Page 7Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- SD-03 Product DataInsulating GlassDocument
39、ation for Energy Star qualifications.Plastic GlazingGlazing AccessoriesManufacturers descriptive product data, handling and storage recommendations, installation instructions, and cleaning instructions. Local/Regional Materials; (LEED)Documentation indicating distance between manufacturing facility
40、and the project site. Indicate distance of raw material origin from the project site. Indicate relative dollar value of local/regional materials to total dollar value of products included in project. Environmental DataSD-04 SamplesInsulating GlassPlastic SheetGlazing CompoundGlazing TapeSealantTwo 2
41、03 by 254 mm 8 by 10 inch samples of each of the following: tinted glass, patterned glass, heat-absorbing glass, _ and insulating glass units.Three samples of each indicated material. Samples of plastic sheets shall be minimum 125 by 175 mm 5 by 7 inches. SD-07 CertificatesInsulating GlassPlastic Gl
42、azingCertificates stating that the glass meets the specified requirements. Labels or manufacturers marking affixed to the glass will be accepted in lieu of certificates. Control Tower Insulating Glass Control Tower Laminated GlassGlazing AccessoriesSECTION 08 81 00 Page 8Provided by IHSNot for Resal
43、eNo reproduction or networking permitted without license from IHS-,-,-Certificates from the manufacturer attesting that the units meet the luminous and solar radiant transmission requirements for heat absorbing glass.SD-08 Manufacturers InstructionsSetting and sealing materialsGlass settingSubmit gl
44、ass manufacturers recommendations for setting and sealing materials and for installation of each type of glazing material specified. Include cleaning instructions for plastic sheets.SD-11 Closeout SubmittalsLocal/Regional Materials; LEEDLEED (tm) documentation relative to local/regional materials credit in accordance with LEED R