1、*USACE / NAVFAC / AFCESA / NASA UFGS-10 22 26.13 (August 2010)-Preparing Activity: NAVFAC Superseding UFGS-10 22 26.13 (October 2007)UFGS-10 22 26.13 (April 2006)UFGS-10 22 26.13 40 (October 2006)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2010*SECTION TAB

2、LE OF CONTENTSDIVISION 10 - SPECIALTIESSECTION 10 22 26.13ACCORDION FOLDING PARTITIONS08/10PART 1 GENERAL1.1 REFERENCES1.2 SUBMITTALS1.3 PRE-INSTALLATION REQUIREMENTS1.3.1 Preconstruction Requirements1.3.2 Product Data1.3.3 Manufacturers Guarantee1.3.4 SUSTAINABLE DESIGN CERTIFICATION1.4 DELIVERY, H

3、ANDLING AND STORAGEPART 2 PRODUCTS2.1 FOLDING PARTITIONS2.2 MATERIALS2.2.1 Aluminum Extrusions2.2.2 Steel Sheets2.2.3 Fabric Covering2.2.4 Seals and Sweepstrips2.2.5 Ceiling Guards2.3 PERFORMANCE REQUIREMENTS2.3.1 Fire Endurance2.3.2 Laboratory Acoustical Requirements2.4 ELECTRICAL OPERATORS2.5 FABR

4、ICATION2.5.1 Framework2.5.2 Suspension System2.5.3 Covering2.5.4 Sound Insulation2.5.5 Air Release2.5.6 Seals2.5.7 Hardware2.5.8 AccessoriesSECTION 10 22 26.13 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-PART 3 EXECUTION3.1 INSTALLATION3.1.

5、1 Existing Work3.1.2 Electrical Operators3.1.3 Adjustment3.2 FIELD TESTS3.2.1 Operational Test3.2.2 Visual Test3.2.3 Acoustical Test3.3 CLEANING3.4 SUPPORT SERVICE- End of Section Table of Contents -SECTION 10 22 26.13 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted withou

6、t license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-10 22 26.13 (August 2010)-Preparing Activity: NAVFAC Superseding UFGS-10 22 26.13 (October 2007)UFGS-10 22 26.13 (April 2006)UFGS-10 22 26.13 40 (October 2006)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL date

7、d July 2010*SECTION 10 22 26.13ACCORDION FOLDING PARTITIONS08/10*NOTE: This guide specification covers the requirements for accordion folding partitions, manually and/or electrically operated.Accordion partitions are folding partitions with independent covers enclosing a dead-air space and separated

8、 by an internal mechanism operating laterally across the face of the opening to a stack or closed position. Do not confuse accordion partitions with serpentine folding partitions which contain no internal operating mechanism or dead-air space between independent covers.Folding partitions may be a si

9、ght barrier (noninsulated), or sound barrier (with sound liner), or both. Accordion-folding partitions have fabric covers which are joined to reflect a pantographic movement of the door surfaces when the door is either manually or electrically operated.This section does not include folding or operab

10、le walls and partitions whose rigid panels are individually moved or hinged along their vertical edges to fold in serpentine fashion.Associated work found in other sections includes:Steel supporting members or hanger rods, Section 05 50 13 MISCELLANEOUS METAL FABRICATIONSSection 05 51 33 METAL LADDE

11、RSSection 05 52 00 METAL RAILINGSSection 05 51 00 METAL STAIRS.Wood blocking, rough bucks, and headers, Section 06 10 00 ROUGH CARPENTRY.Wood trim, wood or hardboard ceiling guard, or soffits, Section 06 20 00 FINISH CARPENTRY.Lock cylinders, Section 08 71 00 DOOR HARDWARE.SECTION 10 22 26.13 Page 3

12、Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Operator field connections to power sources and inner connection to control switches, Division 16, “Electrical.“Edit this guide specification for project specific requirements by adding, deleting, or re

13、vising text. For bracketed items, choose applicable item(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments and suggestions on this guide specification are welcome and should be directed to the tec

14、hnical proponent of the specification. A listing of Technical Proponents, including their organization designation and telephone number, is on the Internet.Recommended changes to a UFGS should be submitted as a Criteria Change Request (CCR).*NOTE: The following information should be shown on the dra

15、wings:1. Location, size, and folding area of accordion partitions.2. Direction of operation, header conditions indicating height, track anchorage, track channel, and jamb conditions.3. Partition supporting structure. The structural support for the partition is not part of this section; it must be in

16、dicated and specified separately.4. A schedule of partitions by type, sizes, and stack space and identified by mark number or letter5. For electrically operated partitions, show power source and desired switch location.*PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publicatio

17、ns cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.SECTION 10 22 26.13 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without li

18、cense from IHS-,-,-Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to update the issue dates.References not used in the

19、 text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the b

20、asic designation only.ASTM INTERNATIONAL (ASTM)ASTM A 653/A 653M (2009a) Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip ProcessASTM B 221 (2008) Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire,

21、 Profiles, and TubesASTM B 221M (2007) Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes (Metric)ASTM C 423 (2009a) Sound Absorption and Sound Absorption Coefficients by the Reverberation Room MethodASTM D 751 (2006) Coated FabricsASTM E 336 (2009)

22、 Measurement of Airborne Sound Insulation in BuildingsASTM E 413 (2004) Rating Sound InsulationASTM E 557 (2000; R 2006) Installation of Operable PartitionsASTM E 84 (2010) Standard Test Method for Surface Burning Characteristics of Building MaterialsASTM E 90 (2009) Standard Test Method for Laborat

23、ory Measurement of Airborne Sound Transmission Loss of Building Partitions and ElementsCHEMICAL FABRICS TIA 09-1; TIA 09-2) Life Safety CodeNFPA 286 (2006) Standard Methods of Fire Tests for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire GrowthNFPA 70 (2008; TIA 08-1) Natio

24、nal Electrical CodeSCIENTIFIC CERTIFICATION SYSTEMS (SCS)SCS Scientific Certification Systems (SCS)Indoor AdvantageUNDERWRITERS LABORATORIES (UL)UL 10B (2008; R thru 2009) Fire Tests of Door Assemblies1.2 SUBMITTALS*NOTE: Review submittal description (SD) definitions in Section 01 33 00 SUBMITTAL PR

25、OCEDURES and edit the following list to reflect only the submittals required for the project. Submittals should be kept to the minimum required for adequate quality control.A “G” following a submittal item indicates that the submittal requires Government approval. Some submittals are already marked

26、with a “G”. Only delete an existing “G” if the submittal item is not complex and can be reviewed through the Contractors Quality Control system. Only add a “G” if the submittal is sufficiently important or complex in context of the project.For submittals requiring Government approval on Army project

27、s, a code of up to three characters within the submittal tags may be used following the “G“ designation to indicate the approving authority. Codes for Army projects using the Resident Management System (RMS) are: “AE“ for Architect-Engineer; “DO“ for District Office (Engineering Division or other or

28、ganization in the District Office); “AO“ for Area Office; “RO“ for Resident Office; and “PO“ for Project Office. Codes following the “G“ typically are not used for Navy, Air Force, and NASA projects.Choose the first bracketed item for Navy, Air Force and NASA projects, or choose the second bracketed

29、 item for Army projects.SECTION 10 22 26.13 Page 6Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*Government approval is required for submittals with a “G“ designation; submittals not having a “G“ designation are for Contractor Quality Control appro

30、val.for information only. When used, a designation following the “G“ designation identifies the office that will review the submittal for the Government. The following shall be submitted in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:SD-01 Preconstruction SubmittalsManufacturers Qualificat

31、ions; G; G, _Manufacturers Sample WarrantyStatement of Code Compliance; G; G, _Statement of Standards Conformity; G; G, _Verification of Field Measurements; G; G, _ Existing Electrical DataSD-02 Shop DrawingsSubmit Fabrication Drawings for Accordion Folding Partitions consisting of fabrication and a

32、ssembly details to be performed in the factory.Submit Installation Drawings for the following items in accordance with paragraph entitled, “Installation,“ of this section.Accordion Folding Partition Layouts; G; G, _Suspension System; G; G, _Finish Hardware; G; G, _Jamb Panels; G; G, _Accessories; G;

33、 G, _ Electrical Operators; G; G, _ Wiring diagrams; G; G, _Submit drawings for the system that include dimensions and weight of stacked partition, layout of the work including stacking area, track and jamb fastening methods, seal details, and installation details. Submit wiring diagram and installa

34、tion details for electrical operator.SD-03 Product DataFrameworkSuspension systemSECTION 10 22 26.13 Page 7Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Finish HardwareSound Seals and SweepstripsCoveringCeiling GuardMeeting PostsJamb PanelsRolling

35、PostPull-In Latch Electrical Operator SwitchesCertificationSD-04 SamplesCovering; G; G, _SD-06 Test ReportsLaboratory Acoustical RequirementsAcoustical testSD-07 CertificatesSubmit Certificates to the Contracting Officer for this installation clearly indicating:Statement of Code Compliance; G; G, _S

36、tatement of Standards Conformity; G; G, _SD-10 Operation and Maintenance DataFolding partitions, Data Package 1; ; G; G, _ Electrical operators, Data Package 5; ; G; G, _Submit in accordance with Section 01 78 23 OPERATION AND MAINTENANCE DATA.SD-11 Closeout SubmittalsManufacturers Guarantee1.3 PRE-

37、INSTALLATION REQUIREMENTS1.3.1 Preconstruction RequirementsNo less than 30 calendar days prior to the scheduled commencement of SECTION 10 22 26.13 Page 8Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-installation of Accordion Folding Partitions, su

38、bmit the following to the Contracting Officer:Manufacturers QualificationsManufacturers Sample WarrantyStatement of Code ComplianceStatement of Standards ConformityVerification of Field Measurementsand Existing Electrical DataFabrication Drawings and Installation Drawings1.3.2 Product DataSubmit the

39、 following information for review:Finish HardwareJamb Panels and AccessoriesSound Seals and SweepstripsCeiling Guard, Meeting Posts, Rolling PostPull-In Latch Electrical Operator and Switches1.3.3 Manufacturers GuaranteeProvide Manufacturers Guarantee for partitions against defects in material and w

40、orkmanship for a period of two years from date of installation. In addition, provide ten year guarantee for the pantographs, trolleys and tracks from date of acceptance for beneficial use.1.3.4 SUSTAINABLE DESIGN CERTIFICATIONProduct shall be third party certified by GEI Greenguard Indoor Air Qualit

41、y Certified, SCS Scientific Certification Systems Indoor Advantage or equal. Certification shall be performed annually and shall be current.1.4 DELIVERY, HANDLING AND STORAGEDeliver materials to project site in manufacturers original, unopened, and undamaged packages with labels legible and intact.

42、Labels must indicate the manufacturer, brand name, size, finish, and placement location. Store folding partitions and accessories in unopened packages in a manner that will prevent damage. Handle partition materials in accordance with manufacturers instructions.PART 2 PRODUCTS2.1 FOLDING PARTITIONSP

43、rovide full accordion type partitions, factory finished, supported from overhead track without floor guides, and complete with all hardware, track, SECTION 10 22 26.13 Page 9Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-and accessories necessary fo

44、r operation. Provide partition framework with a mechanism that gives stability and maintains uniform spacing of partition folds in all partition positions. Provide completely concealed framework with a vinyl-coated fabric covering_. Provide partitions manually and electrically operated, bi-parting a

45、nd one-way type as indicated. Provide patterns and colors of fabric_ approved by the Contracting Officer as indicated . Provide manufacturers standard pendant pull on leading edge of manually operated partitions over 3600 mm 12 feet high.2.2 MATERIALS2.2.1 Aluminum ExtrusionsASTM B 221M ASTM B 221, Alloy 30