1、 Errata NFPA 1994 Standard on Protective Ensembles for First Responders to Hazardous Materials Emergencies and CBRN Terrorism Incidents 2018 Edition Reference: 7.1.2.9.7, 7.3.2.7 and 7.8.10 Errata No: 1994-18-1 The Technical Committee on Hazardous materials Protective Clothing and Equipment, and the
2、 Correlating Committee on Fire and Emergency Services Protective Clothing and Equipment note the following errors in the 2018 edition of NFPA 1994, Standard on Protective Ensembles for First Responders to Hazardous Materials Emergencies and CBRN Terrorism Incidents. 1. Correct the cross reference in
3、 paragraph 7.1.2.9.7 to read as follows: 7.1.2.9.7 Where the Class 1 garment includes elastomeric interface materials, each interface material shall be tested for resistance to flame impingement as specified in Section 8.28 8.27, Flammability Resistance Test, and shall have an afterflame time of not
4、 greater than 2.0 seconds and shall not melt and drip. 2. Correct the cross reference in paragraph 7.3.2.7 to read as follows: 7.3.2.7 Class 2R garment materials and seams shall be tested for resistance to liquid or bloodborne pathogens as specified in Section 8.35 8.20, Viral Penetration Resistance
5、 Test, and shall allow no penetration of the Phi-X-174 bacteriophage for at least 1 hour. 3. Correct the cross reference in paragraph 7.8.10 to read as follows: 7.8.10 Garment materials and, where applicable, visor, glove, footwear, and elastomeric interface materials shall be tested for resistance
6、to flame impingement as specified in Section 8.28 8.27, Flammability Resistance Test, and shall not burn a distance greater than 100 mm (4 in.), shall not sustain burning for more than 2 seconds, and shall not melt and drip Issue Date: September 22, 2017 (Note: Electronic products and pamphlet reprints may have this errata incorporated. For current information about the NFPA Codes and Standards, including this errata, please see www.nfpa.org/docinfo) Copyright 2017 All Rights Reserved NATIONAL FIRE PROTECTION ASSOCIATION