1、 Errata NFPA 61 Standard for the Prevention of Fires and Dust Explosions in Agricultural and Food Processing Facilities 2017 Edition Reference: A.8.7.2.1, A.8.7.2.2, A.8.7.2.4 and A.9.10.1(7) Errata No: 61-17-1 The Technical Committee on Agricultural Dusts and the Correlating Committee on Combustibl

2、e Dusts notes the following error in the 2017 edition of NFPA 61, Standard for the Prevention of Fires and Dust Explosions in Agricultural and Food Processing Facilities. 1. Add Annex material that was omitted in the printing of NFPA 61 to read as follows: A.8.7.2.1 Techniques to prevent or reduce d

3、ust generation and dispersal are vital to any dust control program. These techniques include the use of reduced handling speeds, dead boxes, choked feeding, snorkel loaders, dusttight enclosures, short vertical runs, cleaning, and dust suppressant, as well as many others. Preventive dust control is

4、encouraged, since it can effectively reduce total dust control costs as well as the demands placed on the performance of subsequent dust control techniques outlined in Section 8.4 and 8.7.2. Various oils and other liquids have been used as a dust suppressant. Each dust suppressant has its limitation

5、s and should be used with regard to applicable grain and food standards and regulations. Oil dust suppressants should not be applied directly into the leg, as there have been cases of belt slippage using oil. Application should be made in the transition spout between the receiving pit and the receiv

6、ing leg. If this is not feasible, application can be made at a transfer point or discharge of a conveying system, or directly on a conveyor belt or into a screw auger. The idea is to apply the dust suppressant where there is grain turbulence, thereby allowing the dust suppressant to mix thoroughly.

7、A.8.7.2.2 Legs are the most frequent location of known primary dust explosions and can experience malfunctions, which can result in ignition of the returned dust. This section is not intended to apply to point-of-use dust collectors. A.8.7.2.4 The purpose of this dust control method is to remove dis

8、placed air from the equipment so that it operates under a slightly negative pressure in order to reduce fugitive dust emissions from the equipment, keep the dust generated from the material being conveyed with the material, and eliminate the propagation hazard of interconnecting the conveying equipm

9、ent with a central dust collection system. The dust is not removed from the equipment, and this approach does not lower the risk of a dust deflagration within the equipment itself. The point-of-use dust collector should be located near the material inlet point on the conveyor. Little dust should be

10、drawn into the point-of-use collector. When used on a bucket elevator leg, it is recommended that the point-of-use dust collector be installed in the down leg of the bucket elevator leg to facilitate dust release from the filters. The cross-sectional area of the transition between the duct and the l

11、eg casing should be 2.5 times the cross-sectional area of the dust collector inlet. The angle of the transition duct to the leg casing should be no less than 60 degrees. This dust control method should be used in conjunction with a good housekeeping program, equipment maintenance strategy, and dust

12、deflagration mitigation actions as required. A.9.10.1(7) Contractor records typically include information such as the contract documentation with scope of work and necessary insurance coverage, the contractors safety programs, records demonstrating the contractors safety performance, qualifications

13、and certifications necessary for the work to be done, periodic evaluations of the contractors work performance, and records demonstrating that the employees of the contractor have been trained to safely perform the assigned work. 652:A.9.10.1(8) Issue Date: September 14, 2016 (Note: Electronic products and pamphlet reprints may have this errata incorporated. For current information about the NFPA Codes and Standards, including this errata, please see www.nfpa.org/docinfo) Copyright 2016 All Rights Reserved NATIONAL FIRE PROTECTION ASSOCIATION

展开阅读全文
相关资源
猜你喜欢
  • KS X ISO IEC 9314-8-2003 Information technology-Fibre Distributed Data Interface(FDDI)-Part 8:Media Access Control-2(MAC-2)《信息技术 光纤分布式数据接口(FDDI) 第8部分 媒体访问控制》.pdf KS X ISO IEC 9314-8-2003 Information technology-Fibre Distributed Data Interface(FDDI)-Part 8:Media Access Control-2(MAC-2)《信息技术 光纤分布式数据接口(FDDI) 第8部分 媒体访问控制》.pdf
  • KS X ISO IEC 9314-9-2001 Information technology-Fibre Distributed Data Interface(FDDI)-Part 9:Low-cost fibre physical layer medium dependent《信息技术 光纤分布式数据接口(FDDI) 第9部分 低价光纤物理层相关媒体(L.pdf KS X ISO IEC 9314-9-2001 Information technology-Fibre Distributed Data Interface(FDDI)-Part 9:Low-cost fibre physical layer medium dependent《信息技术 光纤分布式数据接口(FDDI) 第9部分 低价光纤物理层相关媒体(L.pdf
  • KS X ISO IEC 9318-2-2003 Information technology-Intelligent Peripheral Interface-Part 2:Device specific command set for magnetic disk drives《信息技术 智能外围接口 第2部分 磁盘驱动用装置特殊指令集》.pdf KS X ISO IEC 9318-2-2003 Information technology-Intelligent Peripheral Interface-Part 2:Device specific command set for magnetic disk drives《信息技术 智能外围接口 第2部分 磁盘驱动用装置特殊指令集》.pdf
  • KS X ISO IEC 9318-3-2007 Information technology-Intelligent Peripheral Interface-Part 3:Device generic command set for magnetic and optical disk drives《信息技术 智能外围接口 第3部分 磁盘和光盘驱动用设备通.pdf KS X ISO IEC 9318-3-2007 Information technology-Intelligent Peripheral Interface-Part 3:Device generic command set for magnetic and optical disk drives《信息技术 智能外围接口 第3部分 磁盘和光盘驱动用设备通.pdf
  • KS X ISO IEC 9318-4-2007 Information technology-Intelligent Peripheral Interface-Part 4:Device generic command set for magnetic tape drives《信息技术 智能外围接口 第4部分 磁带驱动用设备通用命令集(IPI 3磁带)》.pdf KS X ISO IEC 9318-4-2007 Information technology-Intelligent Peripheral Interface-Part 4:Device generic command set for magnetic tape drives《信息技术 智能外围接口 第4部分 磁带驱动用设备通用命令集(IPI 3磁带)》.pdf
  • KS X ISO IEC 9548-1-2007 Information technology-Open Systems Interconnection-Connectionless Session protocol-Part 1:Protocol specification《信息技术 开放系统互连 无连接会话协议 协议规范》.pdf KS X ISO IEC 9548-1-2007 Information technology-Open Systems Interconnection-Connectionless Session protocol-Part 1:Protocol specification《信息技术 开放系统互连 无连接会话协议 协议规范》.pdf
  • KS X ISO IEC 9576-2-2007 Open systems interconnection-Connectionless presentation protocol:Protocol Implementation Conformance Statement(PICS) proforma《信息技术 开放系统互连 无连接表示协议 协议实现一致性声.pdf KS X ISO IEC 9576-2-2007 Open systems interconnection-Connectionless presentation protocol:Protocol Implementation Conformance Statement(PICS) proforma《信息技术 开放系统互连 无连接表示协议 协议实现一致性声.pdf
  • KS X ISO IEC 9594-10-2007 Information technology-Open Systems Interconnection-The Directory:Use of systems management for administration of the Directory《信息技术 开放系统互连 目录 目录管理机构用的系统管.pdf KS X ISO IEC 9594-10-2007 Information technology-Open Systems Interconnection-The Directory:Use of systems management for administration of the Directory《信息技术 开放系统互连 目录 目录管理机构用的系统管.pdf
  • KS X ISO IEC 9594-7-2007 Information technology-Open Systems Interconnection-The Directory:Selected object classes《信息技术 开放系统互连 目录 选择客体类别》.pdf KS X ISO IEC 9594-7-2007 Information technology-Open Systems Interconnection-The Directory:Selected object classes《信息技术 开放系统互连 目录 选择客体类别》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1