资源描述

1、Lessons Learned Entry: 0312Lesson Info:a71 Lesson Number: 0312a71 Lesson Date: 1994-03-24a71 Submitting Organization: JPLa71 Submitted by: M. P. ZydowiczSubject: ACTS Pyro Separation Band Anomaly (Shuttle Orbiter) Abstract: Minor damage to the Shuttle was caused when the firing of the primary explos

2、ive cord to deploy the payload from the cargo bay also triggered the backup cord. End-to-end system tests had validated the erroneous design rather than the end function. Document electrical-mechanical interfaces, protect hazardous systems against any possible unintended operation, and consider use

3、of a single cord configuration.Description of Driving Event: During the successful deployment of the ACTS/TOS Payload from the STS-51 cargo bay on September 12, 1993, the “SUPER*ZIP“ pyrotechnic separation joint ruptured, producing debris that caused minor damage. Two explosive cords were initiated

4、and operated in the subsystem (when functioning of one cord was desired), causing considerably more energy to be imparted into this subsystem, resulting in the rupture of the containment tube, doubler plates, lead sheathing, silicone rubber extrusion and in the emission of carbon particles (smoke).

5、One affected plate penetrated through the shuttle orbiter aft bulkhead insulation blanket and punctured a 1/8 x 1/2 inch hole in the aft bulkhead. Flight/crew critical equipment exists immediately behind the bulkhead. Other debris caused at least nine small tears in cargo bay insulation blankets, th

6、ree gouges in wire tray covers and possibly a gouge in a thermal protection system tile.The primary cause of the separation system anomaly was a circuit design error, which resulted in firing one end of both the primary and back-up cords, rather than firing both ends of the primary cord. The direct

7、cause of the design error could not be determined. This embedded error remained undetected throughout a series of comprehensive requirements, design and certification reviews and systems tests with wide participation by both the government and contractors. The end-to-end system tests, end-to-end ver

8、ification Ground Support Equipment (GSE), and procedures were established in Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-a manner that validated the erroneous design rather than the end function. This was due in part because of lack of adequate s

9、ystems engineering in the TOS program and because the SUPER*ZIP end-to-end drawings were spread among several individual drawings and never aggregated into a single end-to-end functional electrical/mechanical schematic.Lesson(s) Learned: End-to-end system checks should be performed to verify proper

10、connection, wiring, signal level and function. If necessary, as in the case of pyrotechnic circuits, simulators should be used.Recommendation(s): 1. Develop end-to-end schematics/diagrams for electrical mechanical interfaces including software driven interfaces.2. Require that potentially hazardous

11、systems have demonstrated protection against any possible unintended operation.3. Consider use of a single cord configuration which will prevent this type of event.Evidence of Recurrence Control Effectiveness: N/ADocuments Related to Lesson: N/AMission Directorate(s): N/AAdditional Key Phrase(s): a7

12、1 Configuration Managementa71 Hazardous/Toxic Waste/Materialsa71 Test & VerificationAdditional Info: Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Approval Info: a71 Approval Date: 1994-03-22a71 Approval Name: Carol Dumaina71 Approval Organization: 125-204a71 Approval Phone Number: 818-354-8242Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • BS IEC 61584-2001 Radiation protection instrumentation - Installed portable or transportable assemblies - Measurement of air kerma direction and air kerma rate《辐射保护装置 便携式或可运输安装组件 空.pdf BS IEC 61584-2001 Radiation protection instrumentation - Installed portable or transportable assemblies - Measurement of air kerma direction and air kerma rate《辐射保护装置 便携式或可运输安装组件 空.pdf
  • BS IEC 61624-1998 Guidance on the development of lists of maximum allowable temperatures for polymeric compounds used in electrotechnical equipment《电工技术设备用聚合物最大允许温度一览表制作指南》.pdf BS IEC 61624-1998 Guidance on the development of lists of maximum allowable temperatures for polymeric compounds used in electrotechnical equipment《电工技术设备用聚合物最大允许温度一览表制作指南》.pdf
  • BS IEC 61636-1-2016 Software interface for maintenance information collection and analysis (SIMICA) Exchanging test results and session information via the extensible markup langua.pdf BS IEC 61636-1-2016 Software interface for maintenance information collection and analysis (SIMICA) Exchanging test results and session information via the extensible markup langua.pdf
  • BS IEC 61636-2016 Software Interface for Maintenance Information Collection and Analysis (SIMICA)《维护信息采集与分析用软件接口(SIMICA)》.pdf BS IEC 61636-2016 Software Interface for Maintenance Information Collection and Analysis (SIMICA)《维护信息采集与分析用软件接口(SIMICA)》.pdf
  • BS IEC 61636-99-2016 Software Interface for Maintenance Information Collection and Analysis (SIMICA) Common Information Elements《维护信息采集与分析用软件接口(SIMICA) 公用信息元素》.pdf BS IEC 61636-99-2016 Software Interface for Maintenance Information Collection and Analysis (SIMICA) Common Information Elements《维护信息采集与分析用软件接口(SIMICA) 公用信息元素》.pdf
  • BS IEC 61650-1997 Reliability data analysis techniques - Procedures for comparison of two constant failure rates and two constant failure (event) intensities《可靠性数据分析技术 双恒定失效率和双恒定失效.pdf BS IEC 61650-1997 Reliability data analysis techniques - Procedures for comparison of two constant failure rates and two constant failure (event) intensities《可靠性数据分析技术 双恒定失效率和双恒定失效.pdf
  • BS IEC 61671-2-2016 Standard for automatic test markup language (ATML) instrument description《自动测试标记语言 (ATML) 的仪器描述标准》.pdf BS IEC 61671-2-2016 Standard for automatic test markup language (ATML) instrument description《自动测试标记语言 (ATML) 的仪器描述标准》.pdf
  • BS IEC 61671-2012 IEEE standard for automatic test markup language (ATML) for exchanging automatic test equipment and test information via XML《通过可扩展标示语言(XML)交换自动测试设备和测试信息用自动测试标记语言(.pdf BS IEC 61671-2012 IEEE standard for automatic test markup language (ATML) for exchanging automatic test equipment and test information via XML《通过可扩展标示语言(XML)交换自动测试设备和测试信息用自动测试标记语言(.pdf
  • BS IEC 61671-4-2016 Standard for automatic test markup language (ATML) test configuration《自动测试标记语言 (ATML) 的测试配置标准》.pdf BS IEC 61671-4-2016 Standard for automatic test markup language (ATML) test configuration《自动测试标记语言 (ATML) 的测试配置标准》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1