REG UFGS-26 05 00 00 40-2013 COMMON WORK RESULTS FOR ELECTRICAL.pdf

上传人:周芸 文档编号:1019651 上传时间:2019-03-21 格式:PDF 页数:18 大小:76.58KB
下载 相关 举报
REG UFGS-26 05 00 00 40-2013 COMMON WORK RESULTS FOR ELECTRICAL.pdf_第1页
第1页 / 共18页
REG UFGS-26 05 00 00 40-2013 COMMON WORK RESULTS FOR ELECTRICAL.pdf_第2页
第2页 / 共18页
REG UFGS-26 05 00 00 40-2013 COMMON WORK RESULTS FOR ELECTRICAL.pdf_第3页
第3页 / 共18页
REG UFGS-26 05 00 00 40-2013 COMMON WORK RESULTS FOR ELECTRICAL.pdf_第4页
第4页 / 共18页
REG UFGS-26 05 00 00 40-2013 COMMON WORK RESULTS FOR ELECTRICAL.pdf_第5页
第5页 / 共18页
点击查看更多>>
资源描述

1、*USACE / NAVFAC / AFCEC / NASA UFGS-26 05 00.00 40 (August 2013)-Preparing Activity: NASA SupersedingUFGS-26 05 00.00 40 (November 2010)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2013*SECTION TABLE OF CONTENTSDIVISION 26 - ELECTRICALSECTION 26 05 00.00 40

2、COMMON WORK RESULTS FOR ELECTRICAL08/13PART 1 GENERAL1.1 REFERENCES1.2 DEFINITIONS1.3 SUBMITTALS1.4 PREDICTIVE TESTING AND INSPECTION TECHNOLOGY REQUIREMENTS1.5 QUALITY ASSURANCEPART 2 PRODUCTS2.1 EQUIPMENT2.1.1 Conduits And Raceways2.1.1.1 Rigid Steel Conduit2.1.1.2 Electrical Metallic Tubing (EMT)

3、2.1.1.3 Flexible Metallic Conduit2.1.1.4 Intermediate Metal Conduit2.1.1.5 Rigid Nonmetallic Conduit2.1.1.6 Wireways and Auxiliary Gutters2.1.1.7 Surface Raceways and Assemblies2.1.2 Cable Trays2.1.3 Wire and Cable2.1.4 Switches2.1.4.1 Safety Switches2.1.4.2 Toggle Switches2.1.5 Receptacles2.1.6 Out

4、lets, Outlet Boxes, and Pull Boxes2.1.7 Panelboards2.1.8 Circuit Breakers2.1.9 Lamps and Lighting Fixtures2.1.10 Manufacturers Nameplate2.1.11 Warning Signs2.1.12 Dry-Type Distribution TransformersPART 3 EXECUTION3.1 PREPARATIONSECTION 26 05 00.00 40 Page 1Provided by IHSNot for ResaleNo reproductio

5、n or networking permitted without license from IHS-,-,-3.2 INSTALLATION3.2.1 Conduits, Raceways And Fittings3.2.1.1 Rigid Steel Conduit3.2.1.2 Electrical Metallic Tubing (EMT)3.2.1.3 Flexible Metallic Conduit3.2.1.4 Intermediate Conduit3.2.1.5 Rigid Nonmetallic Conduit3.2.1.6 Wireway and Auxiliary G

6、utter3.2.1.7 Surface Raceways and Assemblies3.2.1.8 Cable Trays3.2.1.9 Splices and Connectors3.2.2 Wiring3.2.3 Safety Switches3.2.4 Wiring Devices3.2.4.1 Wall Switches and Receptacles3.2.4.2 Device Plates3.2.5 Boxes and Fittings3.2.6 Lamps and Lighting Fixtures3.2.7 Panelboards3.2.8 Dry-Type Distrib

7、ution Transformers3.2.9 Field Fabricated Nameplates3.2.10 Identification Plates And Warnings3.2.11 Posted Operating Instructions3.3 FIELD QUALITY CONTROL- End of Section Table of Contents -SECTION 26 05 00.00 40 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without licen

8、se from IHS-,-,-*USACE / NAVFAC / AFCEC / NASA UFGS-26 05 00.00 40 (August 2013)-Preparing Activity: NASA SupersedingUFGS-26 05 00.00 40 (November 2010)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2013*SECTION 26 05 00.00 40COMMON WORK RESULTS FOR ELECTRICA

9、L08/13*NOTE: This guide specification covers the requirements common to all electrical sections.Adhere to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard when editing this guide specification or preparing new project specification sections. Edit this guide specification f

10、or project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments, suggestions and recommended

11、changes for this guide specification are welcome and should be submitted as a Criteria Change Request (CCR).*PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designat

12、ion only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check Refer

13、ence feature to update the issue dates.References not used in the text will automatically SECTION 26 05 00.00 40 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-be deleted from this section of the project specification when you choose to reconc

14、ile references in the publish print process.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.ASTM INTERNATIONAL (ASTM)ASTM D709 (2001; R 2007) Laminated Thermosetting MaterialsELE

15、CTRONIC INDUSTRIES ALLIANCE (EIA)EIA 480 (1981) Toggle SwitchesINSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE)IEEE C57.12.28 (2005; INT 3 2011) Standard for Pad-Mounted Equipment - Enclosure IntegrityIEEE C57.12.29 (2005) Standard for Pad-Mounted Equipment - Enclosure Integrity for Coastal

16、EnvironmentsIEEE Stds Dictionary (2009) IEEE Standards Dictionary: Glossary of Terms R 2011) American National Standard for Safety-Color CodeANSI/NEMA OS 1 (2008; Amd 2010) Sheet-Steel Outlet Boxes, Device Boxes, Covers, and Box SupportsANSI/NEMA OS 2 (2008; AMD 2010) Nonmetallic Outlet Boxes, Devic

17、e Boxes, Covers, and Box SupportsNEMA 250 (2008) Enclosures for Electrical Equipment (1000 Volts Maximum)NEMA FB 1 (2012) Standard for Fittings, Cast Metal Boxes, and Conduit Bodies for Conduit, Electrical Metallic Tubing, and CableNEMA KS 1 (2001; R 2006) Enclosed and Miscellaneous SECTION 26 05 00

18、.00 40 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Distribution Equipment Switches (600 V Maximum)NEMA PB 1 (2011) PanelboardsNEMA RN 1 (2005) Polyvinyl-Chloride (PVC) Externally Coated Galvanized Rigid Steel Conduit and Intermediate Metal

19、ConduitNEMA TC 2 (2003) Standard for Electrical Polyvinyl Chloride (PVC) ConduitNEMA TC 3 (2004) Standard for Polyvinyl Chloride (PVC) Fittings for Use With Rigid PVC Conduit and TubingNEMA VE 1 (2009) Standard for Metal Cable Tray SystemsNEMA WD 1 (1999; R 2005; R 2010) Standard for General Color R

20、equirements for Wiring DevicesNEMA WD 6 (2002; R 2008) Wiring Devices Dimensions SpecificationsNATIONAL FIRE PROTECTION ASSOCIATION (NFPA)NFPA 70 (2011; Errata 2 2012) National Electrical CodeUNDERWRITERS LABORATORIES (UL)UL 1 (2005; Reprint Jul 2012) Standard for Flexible Metal ConduitUL 1242 (2006

21、; Reprint Jul 2012) Standard for Electrical Intermediate Metal Conduit - SteelUL 489 (2013) Molded-Case Circuit Breakers, Molded-Case Switches, and Circuit-Breaker EnclosuresUL 506 (2008; Reprint Oct 2012) Specialty TransformersUL 6 (2007; reprint Nov 2010) Electrical Rigid Metal Conduit-SteelUL 797

22、 (2007; Reprint Dec 2012) Electrical Metallic Tubing - SteelUL 870 (2008; Reprint Feb 2013) Standard for Wireways, Auxiliary Gutters, and Associated FittingsSECTION 26 05 00.00 40 Page 5Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-1.2 DEFINITIONSa

23、. Unless otherwise specified or indicated, electrical and electronics terms used in these specifications, and on the drawings, are as defined in IEEE Stds Dictionary.b. The technical sections referred to herein are those specification sections that describe products, installation procedures, and equ

24、ipment operations and that refer to this section for detailed description of submittal types. c. Vertical assembly: A vertical assembly is a pole, tower or other such support, mounting hardware, arms, brackets and the load. Load can be a luminaire, siren, loudspeaker or other device. All components

25、of a vertical assembly will be rated by the manufacturer to withstand 217_ kilometer/hour 135_ mph wind loading.1.3 SUBMITTALS*NOTE: Review Submittal Description (SD) definitions in Section 01 33 00 SUBMITTAL PROCEDURES and edit the following list to reflect only the submittals required for the proj

26、ect.The Guide Specification technical editors have designated those items that require Government approval, due to their complexity or criticality, with a “G.“ Generally, other submittal items can be reviewed by the Contractors Quality Control System. Only add a “G” to an item, if the submittal is s

27、ufficiently important or complex in context of the project.For submittals requiring Government approval on Army projects, a code of up to three characters within the submittal tags may be used following the “G“ designation to indicate the approving authority. Codes for Army projects using the Reside

28、nt Management System (RMS) are: “AE“ for Architect-Engineer; “DO“ for District Office (Engineering Division or other organization in the District Office); “AO“ for Area Office; “RO“ for Resident Office; and “PO“ for Project Office. Codes following the “G“ typically are not used for Navy, Air Force,

29、and NASA projects.Choose the first bracketed item for Navy, Air Force and NASA projects, or choose the second bracketed item for Army projects.*Government approval is required for submittals with a “G“ designation; submittals not having a “G“ designation are for Contractor Quality Control approval.f

30、or information only. When used, a designation following the “G“ designation identifies the office that will review the submittal for the Government. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:SECTION 26 05 00.00 40 Page 6Provided by IHSNot for ResaleNo reproduction

31、 or networking permitted without license from IHS-,-,-SD-01 Preconstruction SubmittalsMaterial, Equipment, and Fixture Lists; G; G, _SD-03 Product DataConduits and Raceways; G; G, _Wire and Cable; G; G, _Splices and Connectors; G; G, _Switches; G; G, _Receptacles; G; G, _Outlets, Outlet Boxes, and P

32、ull Boxes; G; G, _Circuit Breakers; G; G, _Panelboards; G; G, _Lamps and Lighting Fixtures; G; G, _Dry-Type Distribution Transformers; G; G, _SD-06 Test ReportsContinuity Test; G; G, _Phase-Rotation Tests; G; G, _Insulation Resistance Test; G; G, _SD-07 CertificatesCertification; G; G, _SD-08 Manufa

33、cturers InstructionsManufacturers Instructions; G; G, _1.4 PREDICTIVE TESTING AND INSPECTION TECHNOLOGY REQUIREMENTS*NOTE: The Predictive Testing and Inspection (PT the nameplate of the distributing agent is not acceptable.2.1.11 Warning SignsProvide warning signs for the enclosures of electrical eq

34、uipment including substations, pad-mounted transformers, pad-mounted switches, generators, and switchgear having a nominal rating exceeding 600 volts.a. When the enclosure integrity of such equipment is specified to conform with IEEE C57.12.28 or IEEE C57.12.29, such as for pad-mounted transformers

35、and pad-mounted SF6 switches, provide self-adhesive warning signs on the outside of the high voltage compartment door(s). Provide decal signs with nominal dimensions of 178 by 255 mm 7 by 10 inches. Print the legend “DANGER HIGH VOLTAGE“ in two lines of nominal 50 mm 2 inch high letters. Show the wo

36、rd “DANGER“ in white letters on a red background and the words “HIGH VOLTAGE“ in black letters on a white background. Use Panduit decal No. PPSO710D72 or approved equal. b. When such equipment is guarded by a fence, mount signs on the fence. Provide metal signs having nominal dimensions of 355 by 25

37、5 mm 14 by 10 inches with the legend “DANGER HIGH VOLTAGE KEEP OUT“ printed in three lines of nominal 75 mm 3 inch high white letters on a red and black field.2.1.12 Dry-Type Distribution TransformersGeneral purpose dry-type transformers with windings 600 volts or less are two-winding, 60 hertz, sel

38、f-cooled in accordance with UL 506. Ensure windings have a minimum of two 2-1/2-percent taps above and below nominal voltage.PART 3 EXECUTION3.1 PREPARATION*NOTE: For all outdoor applications and all indoor applications in a harsh environment refer to Section 09 96 00 HIGH-PERFORMANCE COATINGS. High

39、 performance coatings are specified for all outdoor applications because ultraviolet radiation will break down most standard coatings, causing a phenomena known as chalking, which is the first stage of the corrosion process. For additional SECTION 26 05 00.00 40 Page 11Provided by IHSNot for ResaleN

40、o reproduction or networking permitted without license from IHS-,-,-information contact The Coatings Industry Alliance, specific suppliers such as Keeler and Long and PPG, and NACE International (NACE).*Clean and paint conduit, supports, fittings, cabinets, pull boxes, and racks as specified in Sect

41、ion 09 90 00 PAINTS AND COATINGS or Section 09 96 00 HIGH-PERFORMANCE COATINGS.Protect metallic materials against corrosion. Provide equipment enclosures with the standard finish by the manufacturer when used for most indoor installations. For harsh indoor environments (any area subjected to chemica

42、l and/or abrasive action), and all outdoor installations, refer to Section 09 96 00 HIGH-PERFORMANCE COATINGS. Do not use aluminum when in contact with earth or concrete and, where connected to dissimilar metal, protect by approved fittings and treatment. Provide hot-dip galvanized ferrous metals su

43、ch as, but not limited to, anchors, bolts, braces, boxes, bodies, clamps, fittings, guards, nuts, pins, rods, shims, thimbles, washers, and miscellaneous not of corrosion-resistant steel except where other equivalent protective treatment is specifically approved in writing.3.2 INSTALLATION3.2.1 Cond

44、uits, Raceways And FittingsConduit runs between outlet and outlet, between fitting and fitting, or between outlet and fitting cannot contain more than the equivalent of three 90-degree bends, including those bends located immediately at the outlet or fitting.Do not install crushed or deformed conduit. Avoid trapped conduit runs where possible. Take care to prevent the lodgment of foreign material in the conduit, boxes, fittings, and equipment during the course of construction. Clear any clogged conduit of obstructions or be replaced.Conduit and raceway runs concealed in or behind walls, ab

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1