1、_ SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising there
2、from, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions. Copyright 2017 SAE International All rights reserved. No part of this p
3、ublication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-497
4、0 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org SAE values your input. To provide feedback on this Technical Report, please visit http:/standards.sae.org/AMS2224G AEROSPACE MATERIAL SPECIFICATION AMS2224 REV. G Issued 1945-07 Revised 2006-02 Reaffir
5、med 2017-09 Superseding AMS2224F Tolerances Copper and Copper Alloy Wire RATIONALE AMS2224G has been reaffirmed to comply with the SAE Five-Year Review policy. 1. SCOPE: This specification covers established inch/pound manufacturing tolerances applicable to copper and copper alloy wire ordered to in
6、ch/pound dimensions. These tolerances apply to all conditions, unless otherwise noted. 2. DIAMETER OR THICKNESS: 2.1 Metallic Coated, Not Redrawn: 2.1.1 Round Only, Non-Refractory: See Table 1. TABLE 1 - Diameter or Thickness Tolerance Round, Non-Refractory Specified Diameter Inch ToleranceInch plus
7、 Tolerance Inch minus Up to 0.010, incl 0.0001 0.0001 Over 0.010 3.0%D 1.0%D 2.2 Bare and Metallic Coated, Cold Drawn: See 2.2.1 and 2.2.2. 2.2.1 Round, Hexagon, and Octagon: See Table 2. 2.2.2 Square and Rectangular: See Table 3 SAE INTERNATIONAL AMS2224G Page 2 of 3 TABLE 2 - Diameter or Thickness
8、 Tolerance, Round, Hexagon, and Octagon Specified Diameter or Distance Between Parallel Surfaces Inch Tolerance, Inch Plus and Minus Non-Refractory Round Tolerance, Inch Plus and Minus Non-Refractory Hexagon Octagon Tolerance, Inch Plus and Minus Refractory Round Tolerance, Inch Plus and Minus Refra
9、ctory Hexagon Octagon Over Up to 0.010, incl 0.0001 - 0.0002 - Over 0.010 to 0.020, incl 0.0002 - 0.0003 - Over 0.020 to 0.030, incl 0.0003 - 0.0005 - Over 0.030 to 0.040, incl 0.0004 0.0008 0.0007 0.002 Over 0.040 to 0.050, incl 0.0005 0.0010 0.0008 0.003 Over 0.050 to 0.060, incl 0.0006 0.0012 0.0
10、010 0.003 Over 0.060 to 0.080, incl 0.0008 0.0016 0.0015 0.004 Over 0.080 to 0.150, incl 0.0010 0.002 0.002 0.004 Over 0.150 to 0.500, incl 0.0015 0.003 0.002 0.004 Over 0.500 to 0.750, incl 0.002 0.004 0.003 0.005 TABLE 3 - Diameter or Thickness Tolerances, Square and Rectangular Specified Thicknes
11、s Inch Tolerance, Inch Plus and Minus Width Ranges Inch Up to 0.500, incl Copper Tolerance, InchPlus and MinusWidth RangesInch Up to 0.500, inclNon-RefractoryTolerance, InchPlus and MinusWidth RangesInch Up to 0.500, inclRefractory Tolerance, Inch Plus and Minus Width Ranges Inch Over 0.500 to 1.250
12、, incl Copper Tolerance, InchPlus and MinusWidth RangesInch Over 0.500 to 1.250, inclNon-RefractoryTolerance, InchPlus and MinusWidth RangesInch Over 0.500 to 1.250, inclRefractory Over Up to 0.013, incl 0.0010 0.0010 0.0015 0.0013 0.0013 0.002 Over 0.013 to 0.050, incl 0.0013 0.0013 0.0015 0.0015 0
13、.0015 0.002 Over 0.050 to 0.090, incl 0.0015 0.0015 0.002 0.002 0.002 0.003 Over 0.090 to 0.130, incl 0.002 0.002 0.003 0.0025 0.0025 0.004 Over 0.130 to 0.188, incl 0.003 0.003 0.004 0.0035 0.0035 0.0045 3. WIDTH; RECTANGULAR: See Table 4. TABLE 4 - Width Tolerances, Rectangular Specified Width Inc
14、hes Tolerance, Inch Plus and Minus Non-Refractory Tolerance, Inch Plus and Minus Refractory Over Up to 0.050, incl 0.0013 0.0015 Over 0.050 to 0.090, incl 0.0015 0.002 Over 0.090 to 0.130, incl 0.002 0.003 Over 0.130 to 0.188, incl 0.003 0.004 Over 0.188 to 0.500, incl 0.0035 0.005 Over 0.500 to 1.2
15、50, incl 0.005 0.007 SAE INTERNATIONAL AMS2224G Page 3 of 3 4. LENGTH: Square and rectangular wire in straight lengths shall not vary from the ordered length by more than - 0, + 0.375 inch when specific lengths are ordered or by more than - 0, + 1.0 inch when specific lengths with ends or stock leng
16、ths with or without ends are ordered. No length tolerances are established for round, hexagonal, and octagonal wire. 5. STRAIGHTNESS: Square and rectangular wire having cross-sectional area of 0.010 square inch and over and thickness of 0.010 inch and over, when supplied in straight lengths, in roll
17、s, or on bucks, shall be of such straightness that the maximum edgewise curvature (depth of arc) shall be not greater than 0.500 inch in any 6 feet of length, or 0.083 inch x length in feet for shorter lengths. No straightness tolerances are established for round, hexagonal, and octagonal wire, for
18、square and rectangular wire under 0.010 square inch in cross-sectional area or under 0.010 inch thick or when supplied on reels or on stagger-wound rolls. 6. FLATNESS: No requirement established. 7. SPECIAL TOLERANCES: 7.1 If tolerances specified herein are plus and minus and if all plus or all minu
19、s are desired, use the sum of the plus and minus values specified, neglecting the signs. 7.2 If tolerances specified herein are all plus and if all minus are desired, use the same values specified. 7.3 If tolerances specified herein are all plus and if plus and minus are desired, halve the values sp
20、ecified. 8. NOTES: 8.1 A change bar (|) located in the left margin is for the convenience of the user in locating areas where technical revisions, not editorial changes, have been made to the previous issue of this specification. An (R) symbol to the left of the document title indicates a complete r
21、evision of the specification, including technical revisions. Change bars and (R) are not used in original publications, nor in specifications that contain editorial changes only. 8.2 Terms used in AMS are clarified in ARP1917. 8.3 Dimensions and properties in inch/pound units and Fahrenheit temperatures are primary; dimensions and properties in SI units and Celsius temperatures are shown as the approximate equivalents of the primary units and are presented only for information. PREPARED UNDER THE JURISDICTION OF AMS COMMITTEE “D”