资源描述

1、 _ SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising ther

2、efrom, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions. Copyright 2011 SAE International All rights reserved. No part of this

3、publication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-49

4、70 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org SAE values your input. To provide feedback on this Technical Report, please visit http:/www.sae.org/technical/standards/AMS2809A AEROSPACE MATERIAL SPECIFICATION AMS 2809 REV. A Issued 1986-01 Revised

5、 2007-08 Reaffirmed 2011-10 Superseding AMS 2809 Identification Titanium and Titanium Alloy Wrought Products RATIONALE AMS 2809A results from a Five Year Review and update of this specification. 1. SCOPE This specification covers procedures for identifying wrought products of titanium and titanium a

6、lloys. 2. APPLICABLE DOCUMENTS None. 3. TECHNICAL REQUIREMENTS 3.1 Bars and Wire Shall be identified as follows: 3.1.1 Each straight bar over 0.500 inch (12.50 mm) in nominal diameter or least width of flat surface shall be marked in a row of characters recurring at intervals not greater than 3 feet

7、 (900 mm) with the material specification number and its revision letter, if any, heat number, and manufacturers identification. The characters shall be of such size as to be legible, shall be applied using a suitable marking fluid whose residue shall contain not more than traces of halogen-bearing

8、compounds, and shall be removable in hot alkaline cleaning solution without rubbing. The markings shall have no deleterious effect on the product or its performance and shall be sufficiently stable to withstand normal handling. 3.1.2 Straight bars and wire 0.500 inch (12.50 mm) and under in nominal

9、diameter or least width of flat surface shall be securely bundled and identified by a durable tag marked with the purchase order number, the material specification number and its revision letter, if any, heat number, nominal size, and manufacturers identification and attached to each bundle or shall

10、 be boxed and the box marked with the same information. 3.1.3 Coiled bars and wire shall be securely bundled and identified by a durable tag marked with the purchase order number, the material specification number and its revision letter, if any, heat number, nominal size, and manufacturers identifi

11、cation and attached to each coil or shall be boxed and the box marked with the same information. SAE AMS 2809A Page 2 of 3 3.2 Sheet, Strip, and Plate Shall be identified as follows: 3.2.1 Each sheet, strip, and plate shall be marked on one face, in the respective location indicated below, with the

12、material specification number and its revision letter, if any, heat number, manufacturers identification, and nominal thickness. The characters shall be applied using a suitable marking fluid whose residue shall contain not more than traces of halogen-bearing compounds, and shall be removable in hot

13、 alkaline cleaning solution without rubbing. The markings shall have no deleterious effect on the product or its performance and shall be sufficiently stable to withstand normal handling. 3.2.1.1 Flat strip 6 inches (150 mm) and under in width shall be marked in one or more lengthwise rows of charac

14、ters recurring at intervals not greater than 3 feet (900 mm). 3.2.1.2 Flat sheet, flat strip over 6 inches (150 mm) in width and plate shall be marked in lengthwise rows of characters recurring at intervals not greater than 3 feet (900 mm), the rows being spaced not more than 6 inches (150 mm) apart

15、 and alternately staggered. 3.2.1.3 Coiled sheet and strip shall be marked near both the outside and inside ends of the coil; the markings shall be applied as in 3.2.1 or shall appear on a durable tag or label attached to the coil and marked with the information of 3.2.1. When the product is wound o

16、n cores, the tag or label may be attached to the core. 3.3 Aircraft Tubing Shall be identified as follows: 3.3.1 Aircraft Tubing Other Than Hydraulic 3.3.1.1 Straight tubes 0.029 inch (0.75 mm) and over in wall thickness and 0.500 inch (12.50 mm) and over in nominal OD, minor axis, or least width of

17、 flat surface shall be marked in a row of characters recurring at intervals not greater than 3 feet (900 mm) with the material specification number and its revision letter, if any, heat number, manufacturers identification, and nominal wall thickness. The characters shall be of such size as to be le

18、gible, shall be applied using a suitable marking fluid whose residue shall contain not more than traces of halogen-bearing compounds, and shall be removable in hot alkaline cleaning solution without rubbing. The markings shall have no deleterious effect on the tubing or its performance and shall be

19、sufficiently stable to withstand normal handling. 3.3.1.2 Straight tubes under 0.029 inch (0.75 mm) in wall thickness or under 0.500 inch (12.50 mm) in nominal OD, minor axis, or least width of flat surface shall be securely bundled and identified by a durable tag marked with the information of 3.3.

20、1 and attached to each bundle or shall be boxed and the box marked with the same information. 3.3.1.3 Coiled tubing shall be securely bundled and identified by a durable tag marked with the purchase order number, the material specification number and its revision letter, if any, heat number, nominal

21、 OD and wall thickness, and manufacturers identification and attached to each coil or shall be boxed and the box marked with the same information. 3.3.2 Aircraft Hydraulic Tubing 3.3.2.1 Straight tubing 0.029 inch (0.75 mm) and over in wall thickness and 0.250 inch (6.25 mm) and over in OD, minor ax

22、is, or least width of flat surface shall be marked in a row of characters recurring at intervals not greater than 3 feet (900 mm) with the material specification number and its revision letter, if any, heat number, manufacturers identification, and nominal wall thickness. The characters shall be of

23、such size as to be legible, shall be applied using a suitable marking fluid whose residue shall contain not more than traces of halogen-bearing compounds, and shall be removable in hot alkaline cleaning solution without rubbing. The markings shall have no deleterious effect on the tubing or its perf

24、ormance and shall be sufficiently stable to withstand normal handling. SAE AMS 2809A Page 3 of 3 3.3.2.2 Straight tubing under 0.029 inch (0.75 mm) in wall thickness or under 0.250 inch (6.25 mm) in nominal OD, minor axis, or least width of flat surface shall be securely bundled and identified by a

25、durable tag marked with the information of 3.3.2.1 and attached to each bundle or shall be boxed and the box marked with the same information. 3.3.2.3 Coiled tubing shall be securely bundled and identified by a durable tag marked with the purchase order number, the material specification number and

26、its revision letter, if any, heat number, nominal OD and wall thickness, and manufacturers identification and attached to each coil or shall be boxed and the box marked with the same information. 3.4 Extruded Bars, Rods, Tubing, and Shapes Shall be identified as follows: 3.4.1 Each straight bar, rod

27、, and tube 0.500 inch (12.50 mm) and over in nominal OD or least width of flat surface and each straight shape with configuration allowing access to a flat surface at least 0.500 inch (12.50 mm) wide recessed not more than 1 inch (25 mm) below the outline of the shape shall be marked in a row of cha

28、racters recurring at intervals not greater than 3 feet (900 mm) with the material specification number and its revision letter, if any, heat number, and manufacturers identification. The characters shall be of such size as to be legible, shall be applied using a marking fluid whose residue shall con

29、tain not more than traces of halogen-bearing compounds, and shall be removable in hot alkaline cleaning solution without rubbing. The markings shall have no deleterious effect on the product or its performance and shall be sufficiently stable to withstand normal handling. 4. QUALITY ASSURANCE PROVIS

30、IONS Not applicable. 5. PREPARATION FOR DELIVERY Not applicable. 6. ACKNOWLEDGMENT Not applicable. 7. REJECTIONS Product not identified in accordance with this specification or with modifications authorized by purchaser will be subject to rejection. 8. NOTES 8.1 A change bar (|) located in the left

31、margin is for the convenience of the user in locating areas where technical revisions, not editorial changes, have been made to the previous issue of a specification. An (R) symbol to the left of the document title indicates a complete revision of the specification, including technical revision. Cha

32、nge bars and (R) are not used in original publications, nor in specifications that contain editorial changes only. 8.2 Terms used in AMS are clarified in ARP1917. 8.3 Dimensions and properties in inch/pound units and the Fahrenheit temperatures are primary; dimensions and properties in SI units and

33、the Celsius temperatures are shown as the approximate equivalents of the primary units and are presented only for information. 8.4 Similar Specifications FED-STD-184 is listed for information and shall not be construed as an acceptable alternate unless all requirements of this AMS are met. PREPARED BY AMS COMMITTEE “G“

展开阅读全文
相关资源
猜你喜欢
  • BS IEC 61671-4-2016 Standard for automatic test markup language (ATML) test configuration《自动测试标记语言 (ATML) 的测试配置标准》.pdf BS IEC 61671-4-2016 Standard for automatic test markup language (ATML) test configuration《自动测试标记语言 (ATML) 的测试配置标准》.pdf
  • BS IEC 61671-5-2016 Standard for automatic test markup language (ATML) test adapter description《自动测试标记语言 (ATML) 的测试适配器描述标准》.pdf BS IEC 61671-5-2016 Standard for automatic test markup language (ATML) test adapter description《自动测试标记语言 (ATML) 的测试适配器描述标准》.pdf
  • BS IEC 61671-6-2016 Standard for automatic test markup language (ATML) test station description《自动测试标记语言 (ATML) 的测试台描述标准》.pdf BS IEC 61671-6-2016 Standard for automatic test markup language (ATML) test station description《自动测试标记语言 (ATML) 的测试台描述标准》.pdf
  • BS IEC 61691-1-1-2011 Behavioural languages VHDL Language reference manual《行为语言 VHDL语言参考手册》.pdf BS IEC 61691-1-1-2011 Behavioural languages VHDL Language reference manual《行为语言 VHDL语言参考手册》.pdf
  • BS IEC 61747-40-2-2015 Liquid crystal display devices Mechanical testing of display cover glass for mobile devices Uniaxial flexural strength (4-point bend)《液晶显示装置 移动设备用显示保护玻璃的机械试验.pdf BS IEC 61747-40-2-2015 Liquid crystal display devices Mechanical testing of display cover glass for mobile devices Uniaxial flexural strength (4-point bend)《液晶显示装置 移动设备用显示保护玻璃的机械试验.pdf
  • BS IEC 61747-40-3-2015 Liquid crystal display devices Mechanical testing of display cover glass for mobile devices Biaxial flexural energy to failure (ball drop)《液晶显示装置 移动设备用显示保护玻璃.pdf BS IEC 61747-40-3-2015 Liquid crystal display devices Mechanical testing of display cover glass for mobile devices Biaxial flexural energy to failure (ball drop)《液晶显示装置 移动设备用显示保护玻璃.pdf
  • BS IEC 61747-40-4-2015 Liquid crystal display devices Mechanical testing of display cover glass for mobile devices Biaxial flexural strength (ring-on-ring)《液晶显示装置 移动设备用显示保护玻璃的机械试验 .pdf BS IEC 61747-40-4-2015 Liquid crystal display devices Mechanical testing of display cover glass for mobile devices Biaxial flexural strength (ring-on-ring)《液晶显示装置 移动设备用显示保护玻璃的机械试验 .pdf
  • BS IEC 61858-2-2014 Electrical insulation systems Thermal evaluation of modifications to an established electrical insulation system (EIS) Form-wound EIS《电气绝缘系统 对已确立绕线(EIS)改进的热评定 成.pdf BS IEC 61858-2-2014 Electrical insulation systems Thermal evaluation of modifications to an established electrical insulation system (EIS) Form-wound EIS《电气绝缘系统 对已确立绕线(EIS)改进的热评定 成.pdf
  • BS IEC 61865-2002 Overhead lines - Calculation of the electrical component of distance between live parts and obstacles - Method of calculation《架空电线 带电部分和障碍物间距离的电气元件的计算 计算方法》.pdf BS IEC 61865-2002 Overhead lines - Calculation of the electrical component of distance between live parts and obstacles - Method of calculation《架空电线 带电部分和障碍物间距离的电气元件的计算 计算方法》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1