1、 AEROSPACE STANDARD (R) CONNECTOR ACCESSORIES, ELECTRICAL, TERMINATION, SHIELD SPLIT SUPPORT RING, COMPOSITE, NONENVIRONMENTAL, STRAIGHT, CATEGORY 7AS85049/93Copyright 2009 SAE International All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitt
2、ed, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-4970 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB
3、 ADDRESS: http:/www.sae.org ISSUED 2000-06REVISED 2009-10THIRD ANGLE PROJECTION CUSTODIAN: AE-8/AE-8C1 REV.B FEDERAL SUPPLY CLASS 5935 AS85049/93SHEET 1 OF 4 REV. B PROCUREMENT SPECIFICATION: AS85049SAE Technical Standards Board Rules provide that: “This report ispublishedby SAE toadvance thestate o
4、f technicalandengineering sciences. Theuse ofthis report is entirely voluntary, andits applicability and suitability forany particular use,including any patent infringement arising therefrom, isthe soleresponsibilityofthe user.”SAE reviews eachtechnicalreport at least every five years at which time
5、itmay bereaffirmed, revised, orcancelled. SAE invites yourwrittencomments andsuggestions. SAE values your input. To provide feedbackon this Technical Report, please visit http:/www.sae.org/technical/standards/AS85049/93B RATIONALE REVISED TO INCLUDE COMMENTS RECEIVED BY THE GOVERNMENT AND INDUSTRY,
6、REMOVE GOVERNMENT JARGON, AND UP-DATE SPECIFICATION REQUIREMENTS AND REFERENCES. NOTICE THE REQUIREMENTS FOR ACQUIRING THE PRODUCT DESCRIBED HEREIN SHALL CONSIST OF THIS SPECIFICATION SHEET AND THE LATEST ISSUE OF SAE AS85049. FIGURE 1 - CONFIGURATION AND DIMENSIONS Copyright SAE International Provi
7、ded by IHS under license with SAENot for ResaleNo reproduction or networking permitted without license from IHS-,-,-AEROSPACE STANDARD AS85049/93SHEET 2 OF 4REV. B(R) CONNECTOR ACCESSORIES, ELECTRICAL, TERMINATION, SHIELD SPLIT SUPPORT RING, COMPOSITE, NONENVIRONMENTAL, STRAIGHT, CATEGORY 7 FIGURE 1
8、 - CONFIGURATION AND DIMENSIONS (CONTINUED) Copyright SAE International Provided by IHS under license with SAENot for ResaleNo reproduction or networking permitted without license from IHS-,-,-AEROSPACE STANDARD AS85049/93SHEET 3 OF 4REV. B(R) CONNECTOR ACCESSORIES, ELECTRICAL, TERMINATION, SHIELD S
9、PLIT SUPPORT RING, COMPOSITE, NONENVIRONMENTAL, STRAIGHT, CATEGORY 7 TABLE 1 - DIMENSIONS NOTES: 1. DIMENSIONS ARE IN INCHES. 2. METRIC EQUIVALENTS ARE GIVEN FOR GENERAL INFORMATION ONLY AND ARE BASED ON 25.4 mm = 1 INCH, MILLIMETERS ARE IN PARENTHESIS. 3. BREAK ALL SHARP EDGES. 4. INTERIOR FEATURES
10、 ARE SHOWN FOR PICTORIAL REPRESENTATION ONLY; THEIR DIMENSIONS OR ACTUAL NUMBER OF PLACES USED THEREON ARE NOT CONTROLLED IN SO FAR AS ALL PERFORMANCE REQUIREMENTS ARE MET. REQUIREMENTS: DESIGN AND CONSTRUCTION: DIMENSIONS AND CONFIGURATION: SHALL BE IN ACCORDANCE WITH FIGURE 1. FIGURE 1 CONSISTS OF
11、 TWO SPLIT RING HALVES. THE SPLIT RING CONSTRUCTION SHALL HAVE IDENTICAL, INTERCHANGEABLE HALVES WHICH SNAP TOGETHER MANUALLY AND RETAIN THEMSELVES ABOUT A CABLE OR CABLE HARNESS WITHOUT DISENGAGING. THE INDIVIDUAL OR OVERALL WIRE OR CABLE SHIELDING SHALL BE RETAINED ABOUT THE SPLIT RING USING THE A
12、PPROPRIATE BAND SHIELD TERMINATION. THE SPLIT RING SHALL BE CONSTRUCTED SUCH THAT AFTER TERMINATION OF THE INDIVIDUAL OR OVERALL WIRE OR CABLE SHIELDING THERE SHALL BE NO SLIPPAGE AS A RESULT OF THE SPLIT RING CONSTRUCTION. DASHNUMBER ADIA.0100 (0.254) BDIAMAXDIAMETERRANGE04 .250 (6.35) .390(9.9) SM
13、ALL06 .375 (9.52) .515(13.1) 08 .500 (12.70) .640(16.3) 10 .625 (15.88) .770(19.6) 12 .750 (19.05) .903(22.9) MEDIUM 14 .875 (22.22) 1.094 (26.5) 16 1.000 (25.40) 1.173 (29.8) 18 1.125 (28.58) 1.310 (33.3) 20 1.250 (31.75) 1.447(36.8) LARGE 22 1.375 (34.92) 1.578 (40.1) 24 1.500 (38.10) 1.703 (43.3)
14、 26 1.625 (41.28) 1.828 (46.4) 28 1.750 (44.45) 1.953 (49.6) Copyright SAE International Provided by IHS under license with SAENot for ResaleNo reproduction or networking permitted without license from IHS-,-,-AEROSPACE STANDARD AS85049/93SHEET 4 OF 4 REV. B (R) CONNECTOR ACCESSORIES, ELECTRICAL, TE
15、RMINATION, SHIELD SPLIT SUPPORT RING, COMPOSITE, NONENVIRONMENTAL, STRAIGHT, CATEGORY 7 MATERIAL: COMPOSITE, NONCONDUCTIVE, CORROSION RESISTANT IN ACCORDANCE WITH AS85049 (SEE 3.3.2), COLOR IS NATURAL OR BLACK. MARKING: IN ACCORDANCE WITH MIL-STD-1285 AND AS FOLLOWS: PART OR IDENTIFYING NUMBER (PIN)
16、: M85049/ 93 -14 EXAMPLE: BASIC PART NUMBER SPECIFICATION SHEET DASH NUMBER QUALIFICATION: SEE AS85049, CATEGORY 7, WITH THE FOLLOWING ADDITIONS: a. QUALIFICATION TEST SPECIMENS: TEST SPECIMENS SHALL CONSIST OF TWO SAMPLES FROM EACH DIAMETER RANGE (SEE TABLE 1). SAMPLES SHALL BE JOINED TOGETHER WITH
17、 AN AS85049/128 BAND INSTALLED b. HYDROLYTIC STABILITY IN ACCORDANCE WITH AS85049. THERE SHALL BE NO VISUAL CRACKS, LOOSENING OF PARTS NOR SHALL THERE BE AN INCREASE OF WEIGHT GREATER THAN 5 PERCENT. c. TEMPERATURE CYCLING: IN ACCORDANCE WITH AS85049. THERE SHALL BE NO VISIBLE CRACKS NOR LOOSENING O
18、F PARTS. SAMPLES SHALL BE JOINED TOGETHER BY THE SPLIT RETENTION MEANS ONLY. d. SPLIT RING RETENTION: DEVICE SHALL WITHSTAND A PERPENDICULAR PULL FORCE OF 2 POUNDS FOR 5 MINUTES WITHOUT THE RETENTION DEVICE DISENGAGING. e. EACH SAMPLE MUST WITHSTAND 3 BAND TERMINATIONS USING AN AS85049/128 TOOL/BAND
19、 SYSTEM CAPABLE OF INSTALLING A BAND WITH A MINIMUM OF 138 POUND PULL FORCE AND MAXIMUM OF 160 POUND PULL FORCE. THERE SHALL BE NO CRACKS OR RETENTION DEVICE SEPARATION. f. FLUID IMMERSION IN ACCORDANCE WITH AS85049. ONE SAMPLE OF ANY SIZE PER FLUID IS REQUIRED. QUALIFICATION IS REQUIRED FOR U.S. GO
20、VERNMENT PROCUREMENT. 1. SPECIFICATION NOTES: A CHANGE BAR (|) LOCATED IN THE LEFT MARGIN IS FOR THE CONVENIENCE OF THE USER IN LOCATING AREAS WHERE TECHNICAL REVISIONS, NOT EDITORIAL CHANGES, HAVE BEEN MADE TO THE PREVIOUS ISSUE OF THIS DOCUMENT. AN (R) SYMBOL TO THE LEFT OF THE DOCUMENT TITLE INDI
21、CATES A COMPLETE REVISION OF THE DOCUMENT, INCLUDING TECHNICAL REVISIONS. CHANGE BARS AND (R) ARE NOT USED IN ORIGINAL PUBLICATIONS, NOR IN DOCUMENTS THAT CONTAIN EDITORIAL CHANGES ONLY. .Copyright SAE International Provided by IHS under license with SAENot for ResaleNo reproduction or networking permitted without license from IHS-,-,-