SAE J 1117-1986 Method of Measuring and Reporting the Pressure differential-Flow characteristics of a Hydraulic Fluid Power Valve《液压流体动力阀压差流动特性的测量办法和报告》.pdf

上传人:eveningprove235 文档编号:1026134 上传时间:2019-03-21 格式:PDF 页数:7 大小:58.42KB
下载 相关 举报
SAE J 1117-1986 Method of Measuring and Reporting the Pressure differential-Flow characteristics of a Hydraulic Fluid Power Valve《液压流体动力阀压差流动特性的测量办法和报告》.pdf_第1页
第1页 / 共7页
SAE J 1117-1986 Method of Measuring and Reporting the Pressure differential-Flow characteristics of a Hydraulic Fluid Power Valve《液压流体动力阀压差流动特性的测量办法和报告》.pdf_第2页
第2页 / 共7页
SAE J 1117-1986 Method of Measuring and Reporting the Pressure differential-Flow characteristics of a Hydraulic Fluid Power Valve《液压流体动力阀压差流动特性的测量办法和报告》.pdf_第3页
第3页 / 共7页
SAE J 1117-1986 Method of Measuring and Reporting the Pressure differential-Flow characteristics of a Hydraulic Fluid Power Valve《液压流体动力阀压差流动特性的测量办法和报告》.pdf_第4页
第4页 / 共7页
SAE J 1117-1986 Method of Measuring and Reporting the Pressure differential-Flow characteristics of a Hydraulic Fluid Power Valve《液压流体动力阀压差流动特性的测量办法和报告》.pdf_第5页
第5页 / 共7页
点击查看更多>>
资源描述

1、SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirelyvoluntary, and its applicability and suitability for any particular use, including any patent infringement arising therefro

2、m, is the sole responsibility of the user.”SAE reviews each technical report at least every five years at which time it may be reaffirmed, revised, or cancelled. SAE invites your written comments and suggestions.QUESTIONS REGARDING THIS DOCUMENT: (724) 772-8512 FAX: (724) 776-0243TO PLACE A DOCUMENT

3、 ORDER; (724) 776-4970 FAX: (724) 776-0790SAE WEB ADDRESS http:/www.sae.orgCopyright 1986 Society of Automotive Engineers, Inc.All rights reserved. Printed in U.S.A.SURFACEVEHICLE400 Commonwealth Drive, Warrendale, PA 15096-0001RECOMMENDEDPRACTICEJ1117REAF.MAR86Issued 1975-06Reaffirmed 1986-03Supers

4、eding J1117 SEP80METHOD OF MEASURING AND REPORTING THE PRESSURE DIFFERENTIAL-FLOW CHARACTERISTICS OF A HYDRAULIC FLUID POWER VALVEForewordThis Reaffirmed Document has been changed only to reflect the new SAE Technical Standards BoardFormat.As the flow passes through these valves, some power loss is

5、experienced due to restrictions and directionalchanges of the fluid resulting in a differential pressure. Flow is passed through the valve through the ports and inpositions as specified. Pressure is recorded at flow increments to produce a well defined curve. The tare loss ofthe test circuit is subt

6、racted for final data presentation.1. ScopeThis procedure applies to hydraulic fluid power valves as applied to self-propelled work machines asreferenced in SAE J1116.1.1 PurposeTo provide a uniform procedure for measuring and reporting the pressure losses associated withthe significant flow paths i

7、n a hydraulic fluid power valve.2. References2.1 Applicable PublicationsThe following publications form a part of the specification to the extent specifiedherein. Unless otherwise indicated the latest revision of SAE publications shall apply.2.1.1 SAE PUBLICATIONSAvailable from SAE, 400 Commonwealth

8、 Drive, Warrendale, PA 15096-0001.SAEARP24BDetermination of Hydraulic Pressure DropSAEJ1116Categories of Off-Road Self-Propelled Work MachinesSAEJ1117 SEP80Method of Measuring and Reporting the Pressure Differential-Flow Characteristics ofa Hydraulic Fluid Power Valve2.1.2 ANSI PUBLICATIONAvailable

9、from ANSI, 11 West 42nd Street, New York, NY 10036-8002.ANSI B93.2-1971American National Standard Glossary of Terms for Fluid Power, and Supplementsthereto (ISO/TC 131/SC1 (USA-2)3)ANSI Y14.17-1966American National Standard Fluid Power DiagramsCopyright SAE International Provided by IHS under licens

10、e with SAENot for ResaleNo reproduction or networking permitted without license from IHS-,-SAE J1117 Reaffirmed MAR86-2-2.1.3 ASTM PUBLICATIONAvailable from ASTM, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959.ASTMD445-1965American Society for Testing and Materials Standard Method of Test f

11、or Viscosity ofTransparent and Opaque Liquids2.1.4 ISO PUBLICATIONAvailable from ANSI, 11 West 42nd Street, New York, NY 10036-8002.ISO/R 1000-1969International Standard Rules for the Use of Units of theInternational System of Unitsand a Selection of the Decimal Multiples and Submultiples of SI Unit

12、sISO/R 1219-1970International Standard Graphical Symbols for Hydraulic and Pneumatic Equipmentand Accessories for Fluid Power Transmissions (Agrees with ANSI Y32.10-1967) 3. DefinitionsFor definitions of terms not herein defined, see ANSI B93.2-1971.3.1 Test FlowAny steady state flow rate required t

13、o conduct this test.3.2 Input PortAny port into which flow is directed for the purpose of this test.3.3 Output PortAny port from which flow exits for the purpose of this test.3.4 Tare PressureThe pressure loss between the pressure tapping points as generated by the test equipmentexclusive of the tes

14、t valve.3.5 ControlAny externally adjustable feature integral with the test valve that varies the flow path and/or flow rate.3.6 Specified DataThat basic information furnished in the request for the test as indicated in Section 7.4. Units4.1 The International System of Units (SI) is used herein in a

15、ccordance with ISO/R 1000-1969.4.2 Approximate SI conversion units appear before their “Customary U.S.“ counterparts.5. Graphic SymbolsGraphic symbols herein are in accordance with ISO/R 1219-1970 and ANSI/Y14.17-1966.Where ANSI/Y32.10-1967 and ANSI/Y14.7-1966 are not in agreement, ANSI/Y14.7-1966 g

16、overns.6. Letter SymbolsThe following letter symbols are used in this document:TABLE 1SIUnitU.S.UnitP Pressure differential (Pressure drop) kPa (kilopascal) psiPm Measured pressure differential kPa psiPt Tare pressure differential kPa psiP1 Input pressure reading kPa psiP2 Output pressure reading kP

17、a psiQ Test flow L/min USGPMQm Specified maximum flow L/min USGPMCopyright SAE International Provided by IHS under license with SAENot for ResaleNo reproduction or networking permitted without license from IHS-,-SAE J1117 Reaffirmed MAR86-3-7. Summary Of Designated Information:7.1 Specify the follow

18、ing information on all requests for this test:7.1.1 A description of valve.7.1.2 The type of fluid (if different than paragraph 12.1).7.1.3 The fluid temperature (if different from the standardized values in paragraph 12.2).7.1.4 The maximum flow for this test (Qm).7.1.5 The input port(s).7.1.6 The

19、output port(s).7.1.7 The control variable position(s).8. General Procedure8.1 Conduct the test in accordance with the fixed values specified by the test request.8.2 Use only standardized values, shown in Section 12, for catalog information and sales literature.8.3 Test and report of subplate mounted

20、 valves may be run with the subplate included. Reports shall explicitlyindicate how such valves were tested.9. Test Conditions AccuracyMaintain the test condition accuracy within the limits shown in the following table:10. Test Procedure10.1 Install the test valve in the test circuit (see Figure 1)

21、using as input and output ports those indicated in the testrequest.10.2 Set the control variable(s) for the flow path indicated on the test request.10.3 Obtain enough data between zero flow and the specified maximum flow (Qm) to produce a well-defined curveas illustrated in Figure 3. If data is meas

22、ured manually, record on a chart similar to Figure 2.10.4 Remove the test valve from the test circuit and connect the lines used in paragraph 8.1 to complete the testcircuit without the test valve per SAE/ARP 24B-1968 and repeat paragraph 10.3.TABLE 2TestConditionMaintainWithin Flow 2%Pressure 2%Pre

23、ssure Differential 4%Temperature 3 C (5F)Control Variable 2%Copyright SAE International Provided by IHS under license with SAENot for ResaleNo reproduction or networking permitted without license from IHS-,-SAE J1117 Reaffirmed MAR86-4-10.5 Determine the pressure differential (P) by subtracting the

24、tare pressure differential (Pt) from the measuredpressure differential (Pm).10.6 Repeat the test procedure for other specified flow paths and control position.11. Data Presentation11.1 Plot a curve(s) of the pressure differential (P) versus flow rate (Q) using the data obtained as in paragraph10.5.1

25、1.2 Use Figure 3 as an example curve.11.3 Include the following information on the data plot:11.3.1 Valve description11.3.2 Type of fluid11.3.3 Fluid temperature11.3.4 Input port(s) and size11.3.5 Output port(s) and size11.3.6 Control position11.3.7 Date of test11.3.8 Testing agency11.3.9 Output por

26、t pressure at maximum flow12. Standardized Values12.1 A fluid with a viscosity of 2126 mm2/s at 50C (105125 SUS at 122F) and 6.67.4 mm2/s at 90C (4850SUS at 194F) should be used.12.2 Fluid temperature should be 50C (122F).12.3 Use the maximum size for ports if more than one size is available.13. Ide

27、ntification StatementUse the following statement in catalogs and sales literature when electing tocomply with this voluntary standard: “Performance data obtained and presented in accordance with SAERecommended Practice J1117 SEP80“.Copyright SAE International Provided by IHS under license with SAENo

28、t for ResaleNo reproduction or networking permitted without license from IHS-,-SAE J1117 Reaffirmed MAR86-5-FIGURE 1SCHEMATIC EXAMPLE OF A HYDRAULIC VALVE TEST SYSTEMFIGURE 2EXAMPLE OF A CHART FOR THE TEST DATACopyright SAE International Provided by IHS under license with SAENot for ResaleNo reprodu

29、ction or networking permitted without license from IHS-,-SAE J1117 Reaffirmed MAR86-6-FIGURE 3EXAMPLE OF A PRESSURE DIFFERENTIAL VERSUS FLOW CURVEPREPARED BY THE SAE OFF-ROAD MACHINERY TECHNICAL COMMITTEE SC4HYDRAULIC FLUID POWER SYSTEMS AND COMPONENTSCopyright SAE International Provided by IHS unde

30、r license with SAENot for ResaleNo reproduction or networking permitted without license from IHS-,-SAE J1117 Reaffirmed MAR86RationaleNot applicable.Relationship of SAE Standard to ISO StandardNot applicable.ApplicationThis SAE Recommended Practice provides a uniform procedure for measuring and repo

31、rtingthe pressure losses associated with the significant flow paths in a hydraulic fluid power valve.This procedure applies to hydraulic fluid power valves as applied to self-propelled work machines asreferenced in SAE J1116.Reference SectionSAE ARP 24BDetermination of Hydraulic Pressure DropSAE J11

32、16Categories of Off-Road Self-Propelled Work MachinesSAEJ1117 SEP80ANSI B93.2-1971American National Standard Glossary of Terms for Fluid Power, and Supplementsthereto (ISO/TC 131/SC1 (USA-2)3)ANSI Y14.17-1966American National Standard Fluid Power DiagramsASTM D445-1965American Society for Testing an

33、d Materials Standard Method of Test for Viscosity ofTransparent and Opaque LiquidsISO/R 1000-1969International Standard Rules for the Use of Units of the International System of Unitsand a Selection of the Decimal Multiples and Submultiples of SI UnitsISO/R 1219-1970International Standard Graphical

34、Symbols for Hydraulic and Pneumatic Equipmentand Accessories for Fluid Power Transmissions (Agrees with ANSI Y32.10-1967)Developed by the Off-Road Machinery Technical Committee SC4Hydraulic Fluid Power Systems and ComponentsSponsored by the SAE Off-Road Machinery Technical CommitteeCopyright SAE International Provided by IHS under license with SAENot for ResaleNo reproduction or networking permitted without license from IHS-,-