SAE J 1326-2009 Test Method for Measuring Wet Color Transfer Characteristics《湿润传色特性的测量用试验方法》.pdf

上传人:hopesteam270 文档编号:1026268 上传时间:2019-03-21 格式:PDF 页数:2 大小:36.92KB
下载 相关 举报
SAE J 1326-2009 Test Method for Measuring Wet Color Transfer Characteristics《湿润传色特性的测量用试验方法》.pdf_第1页
第1页 / 共2页
SAE J 1326-2009 Test Method for Measuring Wet Color Transfer Characteristics《湿润传色特性的测量用试验方法》.pdf_第2页
第2页 / 共2页
亲,该文档总共2页,全部预览完了,如果喜欢就下载吧!
资源描述

1、_SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising theref

2、rom, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be reaffirmed, revised, or cancelled. SAE invites your written comments and suggestions. Copyright 2009 SAE International All rights reserved. No part of this publication ma

3、y be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: 724-776-4970 (outside USA)

4、Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.orgSURFACEVEHICLERECOMMENDEDPRACTICEJ1326 MAR2009 Issued 1980-08Revised 2009-03 Superseding J1326 FEB1985 (R) Test Method for Measuring Wet Color Transfer Characteristics RATIONALECompletely revised for clarification. Cha

5、nge “NONMETALLIC MATERIALS” TO TEXTILES AND FLEXIBLE PLASTICS”. Update footnotes one and two.1. SCOPE This procedure describes a method of measuring the resistance to wet color transfer of materials such as textiles, leather and composites. 1.1 Purpose The purpose of this testing method is to establ

6、ish a means of ranking the relative resistance to wet color transfer of materials.2. REFERENCES There are no referenced publications specified herein. 3. APPARATUS AND MATERIALS 3.1 AATCC Perspiration Tester, Perspirometer, or equivalent device.13.2 Plates Glass or clear plastic, at least 6 mm (0.2

7、in) larger than the dimensions of the test specimen on all sides. 3.3 Drying Oven 3.4 Multi-fiber Standard Test Fabric, non-fused edges (AATCC) Type I, 6 fiber unless otherwise specified. The pH of the multi-fiber test fabric shall be between 6.5 and 7.5.23.5 AATCC Chromatic Transference Scale33.6 W

8、ringer 1Available from SDL Atlas, 1813A Associates Lane, Charlotte, NC 28217-2956, Tel: 704-329-0911, or equivalent.2Available from Testfabrics Inc., 415 Delaware Avenue, P.O. Box 26, West Pittston, PA 18643, Tel: 570-603-0432, or equivalent.3Available from AATCC, One Davis Drive, Research Triangl

9、e Park, NC 27709, Tel: 919-549-8141, www.aatcc.org or equivalent.Copyright SAE International Provided by IHS under license with SAENot for ResaleNo reproduction or networking permitted without license from IHS-,-,-SAE J1326 Revised MAR2009 Page 2 of 24. TEST SPECIMEN From the multi-fiber test fabric

10、, cut a sample whose width includes all of the 6 fibers, and whose length is equal to or greater than the width. Cut a specimen, which has the same dimensions as the test fabric, from the material to be tested, and place the surface to be tested against the multi-fiber test fabric. This combination

11、will be referenced to as the specimen assembly. 5. PROCEDURE 5.1 Immerse the test specimen assembly in either freshly boiled distilled water or deionized water from an ion-exchange device at room temperature with occasional agitation to insure thorough wetting out (approximately 15 min generally req

12、uired). 5.2 Remove the specimen assembly and pass through the wringer to remove excess liquid when the wet mass is more than three times the dry mass. Whenever possible, the wet mass of the specimen will be 2.5 - 3 times its dry mass. 5.3 Place the specimen assembly between glass or clear plastic pl

13、ates and insert in the specimen unit of the perspiration tester. Adjust the perspiration tester to produce a pressure of 14 kPa on the specimen. 5.4 Place the loaded specimen assembly unit in an oven at 38 1 C so that the plates are in a vertical position and heat for 18 h. Remove the specimen from

14、the unit and complete drying by hanging in air at room temperature. 6. REPORT Classify the staining (color transfer) of the multi-fiber test fabric: CLASS 5 - neglible or no staining CLASS 4 - staining equivalent to Row 4 on the AATCC scale CLASS 3 - staining equivalent to Row 3 on the AATCC scale C

15、LASS 2 - staining equivalent to Row 2 on the AATCC scale CLASS 1 - staining equivalent to Row 1 on the AATCC scale 7. NOTES 7.1 Marginal Indicia A change bar (I) located in the left margin is for the convenience of the user in locating areas where technical revisions, not editorial changes, have bee

16、n made to the previous issue of this document. An (R) symbol to the left of the document title indicates a complete revision of the document, including technical revisions. Change bars and (R) are not used in original publications, nor in documents that contain editorial changes only. PREPARED BY THE SAE TEXTILES AND FLEXIBLE PLASTICS COMMITTEE Copyright SAE International Provided by IHS under license with SAENot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1