SANS 50054-3-2001 Fire detection and fire alarm systems Part 3 Fire alarm devices - Sounders《火灾探测及火警系统 第3部分 火灾报警设备-探测仪》.pdf

上传人:appealoxygen216 文档编号:1030585 上传时间:2019-03-24 格式:PDF 页数:43 大小:275.16KB
下载 相关 举报
SANS 50054-3-2001 Fire detection and fire alarm systems Part 3 Fire alarm devices - Sounders《火灾探测及火警系统 第3部分 火灾报警设备-探测仪》.pdf_第1页
第1页 / 共43页
SANS 50054-3-2001 Fire detection and fire alarm systems Part 3 Fire alarm devices - Sounders《火灾探测及火警系统 第3部分 火灾报警设备-探测仪》.pdf_第2页
第2页 / 共43页
SANS 50054-3-2001 Fire detection and fire alarm systems Part 3 Fire alarm devices - Sounders《火灾探测及火警系统 第3部分 火灾报警设备-探测仪》.pdf_第3页
第3页 / 共43页
SANS 50054-3-2001 Fire detection and fire alarm systems Part 3 Fire alarm devices - Sounders《火灾探测及火警系统 第3部分 火灾报警设备-探测仪》.pdf_第4页
第4页 / 共43页
SANS 50054-3-2001 Fire detection and fire alarm systems Part 3 Fire alarm devices - Sounders《火灾探测及火警系统 第3部分 火灾报警设备-探测仪》.pdf_第5页
第5页 / 共43页
点击查看更多>>
资源描述

1、 Collection of SANS standards in electronic format (PDF) 1. Copyright This standard is available to staff members of companies that have subscribed to the complete collection of SANS standards in accordance with a formal copyright agreement. This document may reside on a CENTRAL FILE SERVER or INTRA

2、NET SYSTEM only. Unless specific permission has been granted, this document MAY NOT be sent or given to staff members from other companies or organizations. Doing so would constitute a VIOLATION of SABS copyright rules. 2. Indemnity The South African Bureau of Standards accepts no liability for any

3、damage whatsoever than may result from the use of this material or the information contain therein, irrespective of the cause and quantum thereof. ICS 13.220.20; 13.320 ISBN 0-626-14402-7 SANS 50054-3:2001 Edition 1 and EN amdt 1 EN 54-3:2001 Edition 1 and amdt 1 Any reference to SABS EN 54-3 is dee

4、med to be a reference to this standard (Government Notice No.1373 of November 2002) SOUTH AFRICAN NATIONAL STANDARD Fire detection and fire alarm systems Part 3: Fire alarm devices Sounders This national standard is the identical implementation of EN 54-3:2001 and amendment 1, and is adopted with th

5、e permission of CEN, rue de Stassart 36, B-1050 Brussels. Published by Standards South Africa 1 dr lategan road groenkloof ! private bag x191 pretoria 0001 tel: 012 428 7911 fax: 012 344 1568 international code + 27 12 www.stansa.co.za Standards South Africa 2003 SANS 50054-3:2001 Edition 1 and EN a

6、mdt1 EN 54-3:2001 Edition 1 and amdt 1 Table of changes Change No. Date Scope EN amdt1 2002 Amended to add Annex ZA which covers additional requirements or other provisions of EU Directives to the products falling within the scope of this standard, and to add a Bibliography. National foreword This S

7、outh African standard was approved by National Committee STANSA TC 68, Security systems, in accordance with procedures of Standards South Africa, in compliance with annex 3 of the WTO/TBT agreement. EUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 54-3:2001/A1June 2002ICS 13.220.20English versionFi

8、re detection and fire alarm systems - Part 3: Fire alarmdevices - SoundersSystmes de dtection et dalarme incendie - Partie 3:Dispositifs sonores dalarme feuBrandmeldeanlagen - Teil 3: Feuermeldeeinrichtungen -Akustische SignalgeberThis amendment A1 modifies the European Standard EN 54-3:2001; it was

9、 approved by CEN on 5 April 2002.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for inclusion of thisamendment into the relevant national standard without any alteration. Up-to-date lists and bibliographical references concerning suchnational

10、 standards may be obtained on application to the Management Centre or to any CEN member.This amendment exists in three official versions (English, French, German). A version in any other language made by translation under theresponsibility of a CEN member into its own language and notified to the Ma

11、nagement Centre has the same status as the official versions.CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece,Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United K

12、ingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2002 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 54-3:2001/A1:2002 EE

13、N 54-3:2001/A1:2002 (E)2ContentspageForeword3Annexe ZA (informative) Clauses of this European Standard addressing essential requirements orother provisions of EU Directives. .5Bibliography 11EN 54-3:2001/A1:2002 (E)3ForewordThis document EN 54-3:2001/A1:2002 has been prepared by Technical Committee

14、CEN/TC 72 “Fire detection andfire alarm systems“, the secretariat of which is held by BSI.This Amendment to the European Standard EN 54-3:2001 shall be given the status of a national standard, eitherby publication of an identical text or by endorsement, at the latest by December 2002, and conflictin

15、g nationalstandards shall be withdrawn at the latest by June 2005.This document has been prepared under a mandate given to CEN by the European Commission and the EuropeanFree Trade Association, and supports essential requirements of the Construction Products Directive (89/106/EEC).For relationship w

16、ith EU Directive(s), see informative annex ZA which is an integral part of this document.According to the CEN/CENELEC Internal Regulations, the national standards organizations of the followingcountries are bound to implement this European Standard: Austria, Belgium, Czech Republic, Denmark, Finland

17、,France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Spain,Sweden, Switzerland and the United Kingdom.EN 54-3:2001/A1:2002 (E)4Change on page 13, 5.7.2.4.a) 5.8.2.4.b to 5.7.2.4.b .ContentsAt the end of the existing table of contents, insert the follow

18、ing new entries:Annex ZA (informative) Clauses of this European Standard addressing essential requirements or otherprovisions of EU DirectivesBibliographyNew annex ZA and BibliographyAfter the existing annex B, add annex ZA and Bibliography as follows:EN 54-3:2001/A1:2002 (E)5Annex ZA(informative)Cl

19、auses of this European Standard addressing essential requirements or other provisions of EU DirectivesZA.1 Scope and relevant clausesThis European Standard has been prepared under the mandate M/109 given to CEN by the European Commissionand the European Free Trade Association.The clauses of this Eur

20、opean Standard, shown in this annex, meet the requirements of the Mandate given underthe EU Construction Products Directive (89/106/EEC).Compliance with these clauses confers a presumption of fitness of the construction product covered by thisEuropean Standard for its intended use according to claus

21、e 1 (Scope) of this standard.WARNING : Other requirements and other EU Directives may be applicable to the product(s) falling within thescope of this standard.NOTE 1 In addition to any specific clauses relating to dangerous substances contained in this standard, there may be otherrequirements applic

22、able to the products falling within its scope (e.g. transposed European legislation and national laws,regulations and administrative provisions). These requirements need also to be complied with, when and where they apply.NOTE 2 An informative database of European and national provisions on dangerou

23、s substances is available at theConstruction web site on EUROPA (CREATE, accessed throughhttp:/europa.eu.int/comm/enterprise/construction/internal/hygiene.htm )This annex ZA has the same scope, in relation to the products covered, as clause 1 of this standard. This annexestablishes the conditions fo

24、r the CE marking of fire alarm sounders intended for the use shown below andidentifies the relevant clauses applicable.EN 54-3:2001/A1:2002 (E)6Construction Product: Fire alarm devices - Sounders for fire detection and fire alarm systems forbuildings.Intended use: Fire Safety.Table ZA.1 - Relevant c

25、lausesEssential characteristics Clauses in thisEuropean StandardMandatedlevel(s)NotesOperational reliability 4.4, 4.5, 4.6, 5.4, 5.17Performance under fire conditions 4.2, 4.3, 5.2, 5.3Durability of operational reliability temperatureresistance5.5, 5.6 a, 5.7 Noneaoutdoor devicesonlyDurability of op

26、erational reliability; vibrationresistance5.12 to 5.15Durability of operational reliability; humidityresistance5.8, 5.9, 5.10a, 5.17aoutdoor devicesonlyDurability of operational reliability; corrosionresistance5.11Durability of operational reliability; electricalstability5.16bbdevices withactive ele

27、ctroniccomponents onlyZA.2 Procedures for the attestation of conformity of fire alarm sounders covered by this standardZA.2.1 System of attestation of conformityThe mandate requires that the attestation of conformity system to be applied shall be that shown in Table ZA.2.Table ZA.2 - Attestation of

28、conformity systemProduct Intended use Levels or classes Attestation ofconformity systemFire detection/Fire alarm:Fire alarm devices - Sounders Fire safety None 1System 1: See CPD Annex III.2.(i), without audit-testing of samplesEN 54-3:2001/A1:2002 (E)7This requires:a) Tasks to be provided by the ma

29、nufacturer:1) factory production control (see ZA.2.2 b);2) testing of samples taken at the factory by the manufacturer in accordance with a prescribed test plan;b) Tasks to be undertaken under the authority of a Notified Product Certification Body1:1) type testing of the product;2) inspection of the

30、 factory and factory production control;3) continuous/periodic surveillance, assessment and approval of the factory production control.ZA.2.2 Evaluation of conformityThe evaluation of conformity of fire alarm sounders covered by this European Standard shall be by the following:a) Type testingType te

31、sting of the product shall be carried out in accordance with the clauses shown in Table ZA.1. Theproducts tested shall be representative of the manufacturers normal production with regard to theirconstruction, operation and calibration. Tests previously performed in accordance with the provisions of

32、 thisstandard may be taken into account providing that they were made to the same system of attestation ofconformity on the same product or products of similar design, construction and functionality, such that theresults may be considered applicable to the product in question. Wherever a change, for

33、 example in theproduct design, materials or supplier of the components or of the production process occurs, which couldchange significantly one or more of the characteristics, the type testing shall be repeated for the relevantproduct performance.b) Factory production controlThe manufacturer shall e

34、stablish, document and maintain a permanent factory production control system toensure that the products placed on the market conform with the stated performance characteristics. Thefactory production control system shall consist of procedures, regular inspections and tests and/orassessments and the

35、 use of the results to control incoming materials or components, equipment, theproduction process and the product.The production control procedure shall be adequately extensive and detailed so that the conformity of theproducts is made apparent to the manufacturer and so that irregularities can be d

36、etected at the earliestpossible stage.A factory production control system conforming with the requirements of EN ISO 9001, and made specific tothe requirements of this standard, should be considered to satisfy the above requirements.The production control procedure shall be recorded in a manual, whi

37、ch shall be made available forinspection.The factory production control shall be recorded. These records shall be available for inspection and shallinclude at least the following:1) identification of the product tested;2) the dates of sampling;3) the test methods applied;4) the test and inspection r

38、esults;5) the date of tests;1A Notified Product Certification Body is an approved product certification body notified to the Commission by a member state,for this purpose, in accordance with article 18 of the Construction Products Directive (89/106/EEC).EN 54-3:2001/A1:2002 (E)86) the identification

39、 of the responsible authority within the factory;7) calibration records;8) actions taken.ZA.3 CE Marking and labelling and accompanying documentationThe CE-marking symbol (in accordance with Directive 93/68/EEC) shall be placed on the product and beaccompanied byi. the identification number of the N

40、otified Product Certification Body;ii. the number of the EC certificate of conformity.The CE marking symbol shall in addition be shown on the accompanying commercial documentation supplementedbya) the identification number of the Notified Product Certification Body;b) the name or identifying mark an

41、d registered address of the manufacturer;c) the last two digits of the year in which the marking was affixed;d) the number of the EC certificate of conformity;e) the reference to this European Standard (EN 54-3);f) the description of the construction product (e.g. Fire alarm devices - Sounders for f

42、ire detection and firealarm systems for buildings);g) the environment category (i.e. Type A: indoor applications or Type B: outdoor applications);h) the type/model designation of the product;i) the data required by 4.6.2 of this standard, apart from that already required by 4.6.1, or a reference to

43、adocument, which shall be uniquely identifiable and available from the manufacturer, containing these data.Where the product exceeds the minimum performance levels stated in this standard, and where the manufacturerso desires, the CE marking may be accompanied by an indication of the parameter(s) co

44、ncerned and the actualtest result(s).EN 54-3:2001/A1:2002 (E)9Figure ZA.1 gives an example of the information to be given on the commercial documents.0123AnyCo Ltd, P.O. Box 21, B1050010123 - CPD 001EN 54-3Fire alarm device - SounderType B: For outdoor useABC 123Technical data: see Doc.123/2000 held

45、 by the manufacturer.Figure ZA.1 - Example of CE marking information on the accompanying commercial documentationZA.4 EC certificate and declaration of conformityThe manufacturer, or his agent established in the EEA, shall prepare and retain a declaration of conformity, whichauthorises the affixing

46、of the CE marking. This declaration shall include:- the name and address of the manufacturer, or his authorised representative established in the EEA, and theplace of production;- the description of the construction product (e.g. Fire alarm device - Sounder for fire detection and fire alarmsystems f

47、or buildings);- the environment category (i.e. Type A: indoor applications or Type B: outdoor applications);- the type/model designation of the product;- the provisions to which the product conforms (e.g. annex ZA of this EN);- any particular conditions applicable to the use of the product if necess

48、ary;- the name and address (or identification number) of the Notified Product Certification Body;- the name of and position held by the person empowered to sign the declaration on behalf of the manufactureror of his authorized representative.The declaration shall contain a certificate of conformity

49、with the following information:- the name and address of the Notified Product Certification Body;- the certificate number;- the name and address of the manufacturer, or his authorised representative established in the EEA;EN 54-3:2001/A1:2002 (E)10- the description of the construction product (e.g. Fire alarm device - Sounder for fire detection and fire alarmsystems for buildings);- the environment category (i.e. Type A: indoor applications or Type B: outdoor applications);- the type/model designation of the product;- the provisions to which the product conforms

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1