TIA-1006-2004 CDMA2000 High Rate Broadcast- Multicast Packet Data Air Interface Specification《CDMA2000高速广播-多播分组数据空中接口规范》.pdf

上传人:roleaisle130 文档编号:1059862 上传时间:2019-03-31 格式:PDF 页数:102 大小:540.18KB
下载 相关 举报
TIA-1006-2004 CDMA2000 High Rate Broadcast- Multicast Packet Data Air Interface Specification《CDMA2000高速广播-多播分组数据空中接口规范》.pdf_第1页
第1页 / 共102页
TIA-1006-2004 CDMA2000 High Rate Broadcast- Multicast Packet Data Air Interface Specification《CDMA2000高速广播-多播分组数据空中接口规范》.pdf_第2页
第2页 / 共102页
TIA-1006-2004 CDMA2000 High Rate Broadcast- Multicast Packet Data Air Interface Specification《CDMA2000高速广播-多播分组数据空中接口规范》.pdf_第3页
第3页 / 共102页
TIA-1006-2004 CDMA2000 High Rate Broadcast- Multicast Packet Data Air Interface Specification《CDMA2000高速广播-多播分组数据空中接口规范》.pdf_第4页
第4页 / 共102页
TIA-1006-2004 CDMA2000 High Rate Broadcast- Multicast Packet Data Air Interface Specification《CDMA2000高速广播-多播分组数据空中接口规范》.pdf_第5页
第5页 / 共102页
点击查看更多>>
资源描述

1、 TIA DOCUMENT CDMA2000 High Rate Broadcast-Multicast Packet Data Air Interface Specification TIA-1006 FEBRUARY 2004 TELECOMMUNICATIONS INDUSTRY ASSOCIATION The Telecommunications Industry Association represents the communications sector of Copyright Telecommunications Industry Association Provided b

2、y IHS under license with EIANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-NOTICE TIA Engineering Standards and Publications are designed to serve the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating intercha

3、ngeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for their particular need. The existence of such Publications shall not in any respect preclude any member or non-member of TIA from manufacturing or selling products

4、not conforming to such Publications. Neither shall the existence of such Documents preclude their voluntary use by non-TIA members, either domestically or internationally. TIA DOCUMENTS TIA Documents contain information deemed to be of technical value to the industry, and are published at the reques

5、t of the originating Committee without necessarily following the rigorous public review and resolution of comments which is a procedural part of the development of a American National Standard (ANS). Further details of the development process are available in the TIA Engineering Manual, located at h

6、ttp:/www.tiaonline.org/standards/sfg/engineering_manual.cfm TIA Documents shall be reviewed on a five year cycle by the formulating Committee and a decision made on whether to reaffirm, revise, withdraw, or proceed to develop an American National Standard on this subject. Suggestions for revision sh

7、ould be directed to: Standards and, 8 therefore, it does not carry payload on behalf of other layers or protocols. 9 This protocol uses the signaling protocol (such as the Signaling Network Protocol defined in 10 Section 2 of 1) negotiated during the session negotiation process to transmit and recei

8、ve 11 messages. 12 2.4.4.3 Procedures 13 2.4.4.3.1 Structure of the BCMCS Flow Identifier 14 A BCMCSFlowID identifies each Broadcast-Multicast flow. The BCMCSFlowID may be 16, 15 24, or 32 bits long. The BCMCSFlowID consists of FlowDiscriminatorLength, Program ID, 16 and Flow Discriminator. The thre

9、e most significant bits of the BCMCSFlowID are called 17 FlowDiscriminatorLength, and indicate the length, in bits, of the Flow Discriminator, which 18 forms the least significant bits of the BCMCSFlowID. Figure 2.4.4.3.1-1 shows the 19 structure of the BCMCS Flow ID for an example where the BCMCSFl

10、owID length is 16 bits, 20 and the Flow Discriminator Length is 7 bits. 21 22 Figure 2.4.4.3.1-1. Example of BCMCSFlowID Structure 23 The access terminal and the access network shall construct the ProgramID by prepending 24 sufficient zeros to the ProgramIDLSBs field of the BroadcastOverhead or 25 BCMCSFlowRegistration or BroadcastReject message, so that the length of the Program ID 26 Copyright Telecommunications Industry Association Provided by IHS under license with EIANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • NEMA ICS 16-2001 Industrial Control and Systems Motion Position Control Motors Controls and Feedback Devices (Revised and Republished from MG 7-1993 Errata 6 13 2002)《工业控制装置及系统运动 位.pdf NEMA ICS 16-2001 Industrial Control and Systems Motion Position Control Motors Controls and Feedback Devices (Revised and Republished from MG 7-1993 Errata 6 13 2002)《工业控制装置及系统运动 位.pdf
  • NEMA ICS 18-2001 Motor Control Centers《马达控制中心》.pdf NEMA ICS 18-2001 Motor Control Centers《马达控制中心》.pdf
  • NEMA ICS 19-2002 Diagrams Device Designations and Symbols for Industrial Controls and Systems《工业控制装置及系统的图表 装置命名和符号》.pdf NEMA ICS 19-2002 Diagrams Device Designations and Symbols for Industrial Controls and Systems《工业控制装置及系统的图表 装置命名和符号》.pdf
  • NEMA ICS 2 3-1995 Instructions for the Handling Installation Operation and Maintenance of Motor Control Centers《马达控制中心的操作 安装 使用和维护指导》.pdf NEMA ICS 2 3-1995 Instructions for the Handling Installation Operation and Maintenance of Motor Control Centers《马达控制中心的操作 安装 使用和维护指导》.pdf
  • NEMA ICS 2 4-2003 NEMA and IEC Devices for Motor Service - A Guide for Understanding the Differences《用于汽车服务业的NEAM及IEC装置 理解差异指南》.pdf NEMA ICS 2 4-2003 NEMA and IEC Devices for Motor Service - A Guide for Understanding the Differences《用于汽车服务业的NEAM及IEC装置 理解差异指南》.pdf
  • NEMA ICS 2 9-2002 Industrial Automation Control Products and Systems Starters Contactors and Overload Relays Rated not more than 2000 Volts AC or 750 Volts DC - Part 9 AC Vacuum-Br.pdf NEMA ICS 2 9-2002 Industrial Automation Control Products and Systems Starters Contactors and Overload Relays Rated not more than 2000 Volts AC or 750 Volts DC - Part 9 AC Vacuum-Br.pdf
  • NEMA ICS 2-2000 Industrial Control and Systems Controllers Contactors and Overload Relays Rated 600 Volts (Incorporates Errata March 2008)《工业控制装置和系统控制器 接触器和额定电压为600 V的超载继电器 包括勘误表.pdf NEMA ICS 2-2000 Industrial Control and Systems Controllers Contactors and Overload Relays Rated 600 Volts (Incorporates Errata March 2008)《工业控制装置和系统控制器 接触器和额定电压为600 V的超载继电器 包括勘误表.pdf
  • NEMA ICS 20-2009 Informational Guide to Electrical Industrial Topics《工业控制器及系统 有关电气工业主题的信息性指南》.pdf NEMA ICS 20-2009 Informational Guide to Electrical Industrial Topics《工业控制器及系统 有关电气工业主题的信息性指南》.pdf
  • NEMA ICS 3 1-2009 Guide for the Application Handling Storage Installation and Maintenance of Medium-Voltage AC Contactors Controllers and Control Centers《中压交流接触器 控制器及控制中心的应用 处理 储存 .pdf NEMA ICS 3 1-2009 Guide for the Application Handling Storage Installation and Maintenance of Medium-Voltage AC Contactors Controllers and Control Centers《中压交流接触器 控制器及控制中心的应用 处理 储存 .pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1