UL 1076-2018 UL Standard for Safety Proprietary Burglar Alarm Units and Systems (Sixth Edition).pdf

上传人:appealoxygen216 文档编号:1067309 上传时间:2019-04-02 格式:PDF 页数:125 大小:1.02MB
下载 相关 举报
UL 1076-2018 UL Standard for Safety Proprietary Burglar Alarm Units and Systems (Sixth Edition).pdf_第1页
第1页 / 共125页
UL 1076-2018 UL Standard for Safety Proprietary Burglar Alarm Units and Systems (Sixth Edition).pdf_第2页
第2页 / 共125页
UL 1076-2018 UL Standard for Safety Proprietary Burglar Alarm Units and Systems (Sixth Edition).pdf_第3页
第3页 / 共125页
UL 1076-2018 UL Standard for Safety Proprietary Burglar Alarm Units and Systems (Sixth Edition).pdf_第4页
第4页 / 共125页
UL 1076-2018 UL Standard for Safety Proprietary Burglar Alarm Units and Systems (Sixth Edition).pdf_第5页
第5页 / 共125页
点击查看更多>>
资源描述

1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 1076 Proprietary Burglar Alarm Units and Systems STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED M

2、ATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Proprietary Burglar Alarm Units and Systems, UL 1076 Sixth Edition, Dated April 6, 2018 Summary of Topics This Sixth Edition of the Standard for Proprietary Burglar Alarm Units and S

3、ystems, UL 1076, was issued to incorporate the following changes: Expand electronic media to include website Revision of minimum wire size requirements in 16.2 and 16.3 Revision to requirements for control units The revised requirements are substantially in accordance with Proposal(s) on this subjec

4、t dated December 5, 2014 and October 23, 2015. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Stan

5、dard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost

6、 savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard,

7、 regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation in

8、troduced while purchaser is storing an electronic Standard on the purchasers computer system. APRIL 6, 2018 UL 1076 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL APRIL 6, 2018 UL 1076 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT

9、AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL APRIL 6, 2018 1 UL 1076 Standard for Proprietary Burglar Alarm Units and Systems The rst and second editions were titled Proprietary Burglar Alarm Systems Units. First Edition July, 1974 Second Edition February, 1980 Thir

10、d Edition March, 1982 Fourth Edition December, 1988 Fifth Edition September, 1995 Sixth Edition April 6, 2018 This ANSI/UL Standard for Safety consists of the Sixth Edition. The most recent designation of ANSI/UL 1076 as an American National Standard (ANSI) occurred on April 6, 2018. ANSI approval f

11、or a standard does not include the Cover Page, Transmittal Pages, and Title Page. The Department of Defense (DoD) has adopted UL 1076 on April 9, 1992. The publication of revised pages or a new edition of this Standard will not invalidate the DoD adoption. Comments or proposals for revisions on any

12、part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at https:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be alt

13、ered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2018 UNDERWRITERS LABORATORIES INC. ANSI/UL 1076-2018UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTIO

14、N WITHOUT PERMISSION FROM UL APRIL 6, 2018 PROPRIETARY BURGLAR ALARM UNITS AND SYSTEMS - UL 1076 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .8 2 Components9 3 Units of Measurement .9 4

15、 Undated References 9 5 Terminology 9 6 Glossary 10 7 Installation and Operating Instructions 13 8 Installation and Operating Instructions Physical Media13 CONSTRUCTION ASSEMBLY 9 General.14 9.1 Product assembly .14 9.2 Electrical protection 15 10 Protection of Service Personnel 19 11 Enclosures .19

16、 11.1 General .19 11.2 Doors and covers 21 11.3 Enclosure openings 21 11.4 Screens and expanded metal 24 11.5 Cast metal.24 11.6 Sheet metal .25 11.7 Product enclosure mounting .27 11.8 Polymeric materials.27 12 Electric Shock 28 13 Corrosion Protection 28 FIELD WIRING CONNECTIONS 14 General29 15 Co

17、rd-Connected Products .29 16 Permanently-Connected Products.30 16.1 General .30 16.2 Field-wiring terminals .31 16.3 Leads .33 16.4 Polarity identication 33 17 Grounding .34 INTERNAL WIRING 18 General35 19 Wiring Methods.35 20 Separation of Circuits .36 21 Bonding for Grounding 37 APRIL 6, 2018 PROP

18、RIETARY BURGLAR ALARM UNITS AND SYSTEMS - UL 1076 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL COMPONENTS, ELECTRICAL 22 General40 22.1 Mounting of components 40 22.2 Insulating materials .41 22.3 Fuseholders .42 22.4 Current-carrying pa

19、rts.42 23 Overcurrent Protection 42 24 Semiconductors 42 25 Switches.42 26 Transformers and Coils43 SPACINGS 27 General43 28 Components .45 PERFORMANCE ALL UNITS 29 General45 29.1 Test units and data .45 29.2 Test samples and miscellaneous data 45 29.3 Test voltages 46 29.4 FCC requirements 46 30 Ce

20、ntral Supervisory Station Equipment 46 31 Normal Operation Test 48 32 Current Protection Test 48 33 Input Test48 34 Output Measurement Test .49 35 Electrical Supervision Test .49 36 Undervoltage Operation Test .50 37 Overvoltage Operation Test 50 38 Variable Ambient Test .50 39 Humidity Test 51 40 E

21、lectric Shock Current Test 51 41 Leakage Current Tests for Cord-Connected Products .55 42 Overload Test 58 42.1 General .58 42.2 Separately Energized Circuits58 43 Endurance Test 59 43.1 General .59 43.2 Separately energized circuits 59 44 Jarring Test 59 45 Power Failure Test60 45.1 General .60 45.

22、2 Receiving units.60 45.3 Protected area units 61 46 Dielectric Voltage-Withstand Test .62 47 Temperature Test.63 48 Abnormal Operation Test 67 49 Electrical Transient Tests 67 49.1 General .67 49.2 Supply line transients .67 APRIL 6, 2018 PROPRIETARY BURGLAR ALARM UNITS AND SYSTEMS - UL 1076 4UL CO

23、PYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 49.3 Internally induced transients .69 49.4 Input/output circuit transients 69 50 AC Induction Test.70 51 Polymeric Materials Test.71 52 Battery Replacement Test .71 53 Strain Relief Test .71 53.1 G

24、eneral .71 53.2 Field-wiring leads.71 54 Ignition Through Bottom-Panel Openings Tests.71 54.1 General .71 54.2 Hot, aming oil .72 54.3 Molten PVC and copper.72 55 Mechanical Strength Tests for Enclosures .73 56 Special Terminal Assemblies Tests .73 56.1 General .73 56.2 Disconnection and reconnectio

25、n .74 56.3 Mechanical secureness .74 56.4 Flexing test 74 56.5 Millivolt drop test .74 56.6 Temperature test .75 INTERCONNECTION AND OPERATION SPECIFIC UNITS CONTROL UNITS 57 General75 DIRECT-WIRE SYSTEMS 58 General75 59 Switchboard Units 76 TRANSMITTER SYSTEMS 60 General77 61 Receiving Units.77 62

26、Transmitting Units 78 63 Dual Signal Line Transmission Methods .78 64 Attack Test.80 COMBINATION SYSTEMS 65 General81 MULTIPLEX SYSTEMS 66 General82 67 Operation 82 68 Packet Switched Data Networks 85 69 Central Supervising Station Units .87 70 Private Radio Facilities 87 71 Standard Line Security E

27、quipment 88 72 Encrypted Line Security Equipment .90 APRIL 6, 2018 PROPRIETARY BURGLAR ALARM UNITS AND SYSTEMS - UL 1076 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL SHORT-RANGE RADIO FREQUENCY (RF) DEVICES 73 General90 74 Time to Report

28、 Alarm .91 75 Inoperative Transmitter Reporting.91 76 Battery Status Indication .92 77 Tamper Protection 92 78 Protection From Interference .93 79 Reference Level Determination .93 79.1 General .93 79.2 Method I 93 79.3 Method 2 95 80 Interference Immunity .98 81 Frequency Selectivity99 82 Clash 100

29、 83 Clash Error .100 84 Error (Falsing) Rate 101 85 Throughput Rate 102 86 Transmitter Stability Test .103 87 Transmitter Accelerated Aging Test 104 88 Installation Instructions and User Manual .104 MANUFACTURING AND PRODUCTION LINE TESTS 89 Production-Line Dielectric Voltage-Withstand Tests 104 90

30、Production-Line Grounding Continuity Test .105 MARKINGS 91 General 106 92 Marking Permanency Tests .108 ACCESSORY EQUIPMENT 93 General 108 94 Construction 109 95 Performance (Installation) Test 109 96 Markings .109 PROPRIETARY BURGLAR ALARM SERVICE 97 Physical Protection 110 98 Alarm-Receiving Equip

31、ment.110 99 Alarm and Signal Transmission, and Protected Area Control Units.111 100 Fire Protection .111 101 Emergency Lighting.112 102 Clocks 112 103 Power Supply 112 103.1 General .112 103.2 Installation 112 103.3 Main power supply .113 103.4 Secondary power supply 113 103.5 Storage batteries.114

32、APRIL 6, 2018 PROPRIETARY BURGLAR ALARM UNITS AND SYSTEMS - UL 1076 6UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 103.6 Battery overcurrent protection .114 103.7 Charging method 114 103.8 Cycle-charged batteries .114 103.9 Trickle- or oat

33、-charged batteries 115 103.10 Rectiers and motor generators.115 103.11 Engine-driven generator sets .116 103.12 Security117 104 Personnel .117 105 Service 118 APPENDIX A Standards for ComponentsA1 APRIL 6, 2018 PROPRIETARY BURGLAR ALARM UNITS AND SYSTEMS - UL 1076 7UL COPYRIGHTED MATERIAL NOT AUTHOR

34、IZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements apply to the construction, performance and operation of equipment intended for use in proprietary burglar alarm units and systems used to protect against burglary. These products are

35、normally intended for indoor use. 1.2 A proprietary burglar alarm system as referred to by these requirements is a system in which alarm initiating circuits and devices are installed at a property and are connected directly or indirectly to constantly monitored receiving equipment at a central super

36、vising station. The central supervising station is located at the protected property and intended for operation by personnel responsible to the owner of the protected property. The protected property may consist of a single property or of noncontiguous properties under a single ownership. The system

37、 is arranged so that a predetermined change in the alarm initiating circuits or devices automatically causes transmission of an alarm signal over a supervised signaling channel to the central supervising station. 1.3 These systems normally operate within the limits of Class 2 remote-control and sign

38、al circuits as dened by Article 725 of the National Electrical Code, NFPA 70. 1.4 The protection circuit must respond to both an increase and a decrease in the circuit resistance or current within the limits indicated in the appropriate sections of this standard. See 58.3, 62.2, and 67.6. 1.5 A syst

39、em that provides line security may be classied as either standard line security or encrypted line security. See Standard Line Security Equipment, Section 71, and Encrypted Line Security Equipment, Section 72. 1.6 Protective devices installed on individual properties are further classied as to extent

40、 of protection at each location. Requirements covering installation and classication (of extent) of alarm protective equipmentatindividuallocationsarepublishedintheStandardforInstallationandClassicationofBurglar and Holdup Alarm Systems, UL 681, which is intended to be referenced by burglar-alarm in

41、stallers. 1.7 Proprietary burglar alarm units and systems are also specially designated as to their intended use on mercantile premises, mercantile safes and vaults, and bank safes and vaults. 1.8 Equipment intended for combination burglar alarm and re-protective signaling systems shall comply with

42、the requirements in the Standard for Control Units and Accessories for Fire Alarm Systems, UL 864. APRIL 6, 2018 PROPRIETARY BURGLAR ALARM UNITS AND SYSTEMS - UL 1076 8UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 2 Components 2.1 Except a

43、s indicated in 2.2, a component of a product covered by this standard shall comply with the requirements for that component. See Appendix A for a list of standards covering components generally used in the products covered by this standard. 2.2 A component is not required to comply with a specic req

44、uirement that: a) Involves a feature or characteristic not required in the application of the component in the product covered by this standard, or b) Is superseded by a requirement in this standard. 2.3 A component shall be used in accordance with its rating established for the intended conditions

45、of use. 2.4 Specic components are incomplete in construction features or restricted in performance capabilities. Such components are intended for use only under limited conditions, such as certain temperatures not exceeding specied limits, and shall be used only under those specic conditions. 3 Unit

46、s of Measurement 3.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory or approximate information. 3.2 Unless otherwise indicated, all voltage and current values mentioned in this standard are root-mean-square (rms). 4 Undated References 4.1 Any undated ref

47、erence to a code or standard appearing in the requirements of this standard shall be interpreted as referring to the latest edition of that code or standard. 5 Terminology 5.1 The term product as used in this standard refers to all types of proprietary burglar alarm units and systems. APRIL 6, 2018

48、PROPRIETARY BURGLAR ALARM UNITS AND SYSTEMS - UL 1076 9UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 6 Glossary 6.1 For the purpose of this standard the following denitions apply. 6.2 ACKNOWLEDGEMENT SIGNAL An audible and/or visual signal

49、that is sent to the subscriber by the central station to notify the subscriber that a signal has been received indicating that the protection system has been properly armed. The acknowledgement signal can be sent manually or automatically. 6.3 CENTRAL SUPERVISORY STATION A physically protected building or enclosed area within a building that is constantly manned for the purpose of providing immediate attention to all signals received from the protected areas. 6.4 CIRCUITS, ELECTRICAL: a) HIGH-VOL