UL SUBJECT 693-2006 Outline of Investigation for Excess Pressure Pumps for Wet Pipe Sprinkler Systems (Issue 3)《湿管喷淋系统用超压泵调查大纲 发布编号 3》.pdf

上传人:explodesoak291 文档编号:1069471 上传时间:2019-04-02 格式:PDF 页数:6 大小:17.94KB
下载 相关 举报
UL SUBJECT 693-2006 Outline of Investigation for Excess Pressure Pumps for Wet Pipe Sprinkler Systems (Issue 3)《湿管喷淋系统用超压泵调查大纲 发布编号 3》.pdf_第1页
第1页 / 共6页
UL SUBJECT 693-2006 Outline of Investigation for Excess Pressure Pumps for Wet Pipe Sprinkler Systems (Issue 3)《湿管喷淋系统用超压泵调查大纲 发布编号 3》.pdf_第2页
第2页 / 共6页
UL SUBJECT 693-2006 Outline of Investigation for Excess Pressure Pumps for Wet Pipe Sprinkler Systems (Issue 3)《湿管喷淋系统用超压泵调查大纲 发布编号 3》.pdf_第3页
第3页 / 共6页
UL SUBJECT 693-2006 Outline of Investigation for Excess Pressure Pumps for Wet Pipe Sprinkler Systems (Issue 3)《湿管喷淋系统用超压泵调查大纲 发布编号 3》.pdf_第4页
第4页 / 共6页
UL SUBJECT 693-2006 Outline of Investigation for Excess Pressure Pumps for Wet Pipe Sprinkler Systems (Issue 3)《湿管喷淋系统用超压泵调查大纲 发布编号 3》.pdf_第5页
第5页 / 共6页
点击查看更多>>
资源描述

1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULDecember 5, 20061SUBJECT 693OUTLINE OF INVESTIGATIONFOREXCESS PRESSURE PUMPS FOR WET PIPE SPRINKLER SYSTEMSIssue Number: 3DECEMBER 5, 2006Summary of TopicsThis new issue of SU 693 is being issued

2、 through ULs electronicpublishing system to ensure format uniformity between the PDF andHTML versions of the document. No substantive changes have beenincorporated in the document.The UL Foreword is no longer located within the UL Standard. For informationconcerning the use and application of the re

3、quirements contained in thisStandard, the current version of the UL Foreword is located onULStandardsInfoNet at: http:/ 2006 UNDERWRITERS LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULDECEMBER 5, 2006SUBJECT 6932No Text on T

4、his PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSGENERAL1 General 4PERFORMANCE2 General 43 Installation Test .54 Operational Test 55 Endurance Test .56 Hydrostatic Pressure Strength Test .6MARKING7 General 6DECEMBER 5, 2006 SUBJ

5、ECT 693 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULGENERAL1 General1.1 Excess pressure pumps are intended for installation on wet pipe sprinkler systems as a means ofestablishing excess pressure for suppression of false alarms due to wat

6、er surges (water hammer).1.2 The purpose of the investigation of the excess pressure pump is to determine that it is designed forinstallation on alarm check valve equipped, wet pipe sprinkler systems to provide an automaticallycontrolled means of maintaining excess pressure in the systems, substanti

7、ally in excess of the maximumpressure likely to be present in the supply lines.1.3 Maintenance of excess pressure in systems at all times is intended to prevent movement of the alarmvalve clapper during surges of the water supply line pressure thus eliminating false alarms due to flowthrough the val

8、ve occasioned by surges. The pump assembly and the required control pressure switchesare to be securely installed on a heavy gauge metal panel which in turn is intended for installation on asprinkler riser immediately above the alarm valve.1.4 The panel is generally fastened to a wall or the sprinkl

9、er riser close to the alarm check valve. Thepanel incorporates a control circuit, armor cable, electric motor, mounting plate, differential pressureswitch, low pressure supervisory switch, pump, and low pressure alarm switch. The electrical componentsare to be covered by the UL Recognized Component

10、Program and each part is clearly identified as such.1.5 All the electrical components are to be reviewed and tested by ULs Burglary Protection and SignalingDepartment and the following tests conducted:a) Input Test,b) Temperature Test,c) Dielectric Strength Test.PERFORMANCE2 General2.1 In addition,

11、the following operational tests of the complete excess pressure pump assembly are to beconducted with the panel installed in a wet pipe sprinkler system.DECEMBER 5, 2006SUBJECT 6934UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL3 Installation

12、 Test3.1 The excess pressure pump panel is to be installed directly on a test sprinkler riser at a pointimmediately above an alarm valve. Connections are to be made between the pump assembly and thealarm valve. A pressure switch is to be connected by piping to the alarm port on the alarm valve and t

13、oa suitable power source and lamp bank to indicate valve clapper movement during the various tests.4 Operational Test4.1 The operational test is to be conducted to develop the characteristics of the excess pressure pumpunder water supply pressure conditions within the limits of its pressure rating a

14、nd under varied entrappedair conditions in the test sprinkler piping. To simulate the entrapped air conditions present in wet pipesprinkler systems, the air volume in the test system is to be varied and the effects on the operation of theexcess pressure pump is to be recorded. In order to evaluate t

15、he entrapped air condition with respect towet pipe sprinkler systems in service, the flexibility of the test system is to be measured. Flexibility is aterm used for the entrapped air conditions of wet pipe sprinkler systems. The flexibility of a wet pipesystem at any stated pressure is the number of

16、 gallons of water which must be withdrawn from the riserwhen the main gate is closed in order to reduce the riser pressure 10 psi. The gallon value reflects theentrapped air volume in the piping system. The time required to initiate alarms in the cases of wet pipesprinkler systems equipped with alar

17、m valves depends upon a number of factors among which are:a) The system flexibility conditions,b) The differential of pressure existing between the supply pressure and the system pressure,andc) Rate of flow from the system.5 Endurance Test5.1 The excess pressure pump will be operated intermittently

18、on and off for a period of 24 hours. Toaccomplish this a small flow will continuously discharge from the test piping. Since the outflow will notexceed the capacity of the pump, it shall permit the pump to undergo a constant on and off cyclingoperation for 24 hours. This test will be conducted to asc

19、ertain whether any failure would occur in themotor, pump, or pressure switches due to abnormal operating conditions and also to observe thefunctioning of the complete unit under the on and off cycling operation.DECEMBER 5, 2006 SUBJECT 693 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUC

20、TION ORDISTRIBUTION WITHOUT PERMISSION FROM UL6 Hydrostatic Pressure Strength Test6.1 The pressure switches in the assembly are to be individually subjected to a hydrostatic pressure of875 psi for 1 minute. The samples are to be subjected to five times the normal working pressure (175 psi)to ascertain whether the water would enter the switch enclosure by leaking past the plunger assembly.MARKING7 General7.1 Each excess pressure pump shall be marked with the manufacturers name, model number, electricalrating, and maximum pressure rating on standard metal nameplate.DECEMBER 5, 2006SUBJECT 6936

展开阅读全文
相关资源
猜你喜欢
  • ASD-STAN PREN 3287-1987 Aerospace Series Bearings-Airframe Rolling Double Row Self-Aligning Ball Bearings in Steel Diameter Series 2 Dimensions Torques Clearances and Loads (Issue .pdf ASD-STAN PREN 3287-1987 Aerospace Series Bearings-Airframe Rolling Double Row Self-Aligning Ball Bearings in Steel Diameter Series 2 Dimensions Torques Clearances and Loads (Issue .pdf
  • ASD-STAN PREN 3288-1987 Aerospace Series Bearings-Airframe Rolling Double Row Self-Aligning Ball Bearings in Steel Cadmium Plated Diameter Series 2 Dimensions Torques Clearances an.pdf ASD-STAN PREN 3288-1987 Aerospace Series Bearings-Airframe Rolling Double Row Self-Aligning Ball Bearings in Steel Cadmium Plated Diameter Series 2 Dimensions Torques Clearances an.pdf
  • ASD-STAN PREN 3289-1987 Aerospace Series Bearings-Airframe Rolling Double Row Self-Aligning Ball Bearings in Corrosion Resisting Steel Diameter Series 2 Dimensions Torques Clearanc.pdf ASD-STAN PREN 3289-1987 Aerospace Series Bearings-Airframe Rolling Double Row Self-Aligning Ball Bearings in Corrosion Resisting Steel Diameter Series 2 Dimensions Torques Clearanc.pdf
  • ASD-STAN PREN 3290-1987 Aerospace Series Bearings-Airframe Rolling Single Row Self-Aligning Roller Bearings in Steel Diameter Series 3 and 4 Dimensions Torques Clearances and Loads.pdf ASD-STAN PREN 3290-1987 Aerospace Series Bearings-Airframe Rolling Single Row Self-Aligning Roller Bearings in Steel Diameter Series 3 and 4 Dimensions Torques Clearances and Loads.pdf
  • ASD-STAN PREN 3291-1987 Aerospace Series Bearings-Airframe Rolling Single Row Self-Aligning Roller Bearings in Steel Cadmium Plated Diameter Series 3 and 4 Dimensions Torques Clear.pdf ASD-STAN PREN 3291-1987 Aerospace Series Bearings-Airframe Rolling Single Row Self-Aligning Roller Bearings in Steel Cadmium Plated Diameter Series 3 and 4 Dimensions Torques Clear.pdf
  • ASD-STAN PREN 3292-1987 Aerospace Series Bearings-Airframe Rolling Single Row Self-Aligning Roller Bearings in Corrosion Resisting Steel Diameter Series 3 and 4 Dimensions Torques .pdf ASD-STAN PREN 3292-1987 Aerospace Series Bearings-Airframe Rolling Single Row Self-Aligning Roller Bearings in Corrosion Resisting Steel Diameter Series 3 and 4 Dimensions Torques .pdf
  • ASD-STAN PREN 3293-1989 Aerospace Series Bolts T-Head Close Tolerance Medium Thread Length in Heat Resisting Nickel Base Alloy N1-P100HT (Inconel 718) Uncoated Classification  1275.pdf ASD-STAN PREN 3293-1989 Aerospace Series Bolts T-Head Close Tolerance Medium Thread Length in Heat Resisting Nickel Base Alloy N1-P100HT (Inconel 718) Uncoated Classification 1275.pdf
  • ASD-STAN PREN 3294-1989 Aerospace Series Bolts T-Head Close Tolerance in Heat Resisting Nickel Base Alloy NI-P101HT (Waspaloy) Uncoated for Increased Height Nuts Classification  12.pdf ASD-STAN PREN 3294-1989 Aerospace Series Bolts T-Head Close Tolerance in Heat Resisting Nickel Base Alloy NI-P101HT (Waspaloy) Uncoated for Increased Height Nuts Classification 12.pdf
  • ASD-STAN PREN 3295-1999 Aerospace Series Shaft-Nuts Self-Locking in FE-PA92HT (A286) Silver Plated (Edition P 3 )《航空航天系列 镀银FE-PA92HT(A286)制自锁柄螺母 第P3版 [替代为 ASD-STAN PREN 4396]》.pdf ASD-STAN PREN 3295-1999 Aerospace Series Shaft-Nuts Self-Locking in FE-PA92HT (A286) Silver Plated (Edition P 3 )《航空航天系列 镀银FE-PA92HT(A286)制自锁柄螺母 第P3版 [替代为 ASD-STAN PREN 4396]》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1