VA 08 33 13-2011 COILING COUNTER DOORS.pdf

上传人:sofeeling205 文档编号:1074743 上传时间:2019-04-06 格式:PDF 页数:7 大小:63.97KB
下载 相关 举报
VA 08 33 13-2011 COILING COUNTER DOORS.pdf_第1页
第1页 / 共7页
VA 08 33 13-2011 COILING COUNTER DOORS.pdf_第2页
第2页 / 共7页
VA 08 33 13-2011 COILING COUNTER DOORS.pdf_第3页
第3页 / 共7页
VA 08 33 13-2011 COILING COUNTER DOORS.pdf_第4页
第4页 / 共7页
VA 08 33 13-2011 COILING COUNTER DOORS.pdf_第5页
第5页 / 共7页
点击查看更多>>
资源描述

1、10-11 08 33 13 - 1 SECTION 08 33 13 COILING COUNTER DOORS SPEC WRITER NOTE: 1. Delete between /_/ if not applicable to project. Also delete any other item or paragraph not applicable in the section and renumber the paragraphs. 2. Use overhead coiling counter shutters as pass windows closures. 3. Use

2、 fire rated overhead coiling counter shutters in fire rated partitions and to supplement glazed openings such as service window units-bullet resistant openings. Insure unit location closes deal tray openings. PART 1 -GENERAL 1.1 DESCRIPTION A. Section specifies overhead roll up coiling shutters over

3、 counter in walls, including frame and counter. B. Manual push up operation, / and crank up operation /. 1.2 RELATED WORK A. Lock cylinder and keying: Section 08 71 00, DOOR HARDWARE. B. Color of shutter; Section 09 06 00, SCHEDULE FOR FINISHES. C. Field Painting: Section 09 91 00, PAINTING. 1.3 SUB

4、MITTALS A. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES. B. Manufacturers Literature and Data: Shutter, each type. Installation procedures and instructions. C. Shop Drawings: Shutter, each type, showing details of construction and installation. SPEC WRITER NOT

5、E: Update applicable publications to current insure at time of project specification preparation. 1.4 APPLICABLE PUBLICATIONS A. Publications listed below form a part of this specification to extent referenced. Publications are referenced in text by basic designation only. B. American Society for Te

6、sting and Materials (ASTM): A47-99(R2009) Malleable Iron Castings Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-10-11 08 33 13 - 2 A48-03(R2008) Gray Iron Castings A53-10 . Pipe, Steel, Black and Hot-Dipped, Zinc-Coated Welded and Seamless A167-99(

7、R2009) . Stainless and Heat-Resisting Chromium-Nickel Steel Plate, Sheet and Strip A653-10 Steel Sheet Zinc-Coated (Galvanized) or Zinc-Iron Alloy Coated (Galvannealed) by the Hot Dip Process B209-07 Aluminum and Aluminum-Alloy Sheet and Plate B221-08 Aluminum and Aluminum-Alloy Extruded Bars, Rods,

8、 Wire, Shapes, and Tubes F468-10 Nonferrous Bolts, Hex Cap Screws, and Studs for General Use F593-02(R2008) . Stainless Steel Bolts, Hex Cap Screws, and Studs C. American Welding Society (AWS): D1.1-10 Structural Welding Code Steel D1.2-08 Structural Welding Code Aluminum D1.3-08 Structural Welding

9、Code Sheet Steel D. National Association of Architectural Metal Manufacturers (NAAMM) AMP 500 Series-2006 Metal Finishes Manual E. American Architectural Manufacturers Association (AAMA): 2605-11 Voluntary Specification for High Performance Organic Coatings on Architectural Extrusions and Panels F.

10、Federal Specifications (Fed. Spec): TT-P-645B Primer, Paint, Zinc-Molybdates, Alkyd Type G. National Fire Protection Association (NFPA): 80-10 Fire Doors and Fire Windows PART 2 - PRODUCTS SPEC WRITER NOTE: Make material requirements agree with applicable requirements specified in the referenced App

11、licable Publications. Update and specify only that which applies to the project. 2.1 MATERIALS A. Aluminum: 1. Extruded: ASTM B221, alloy 6063-T5. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-10-11 08 33 13 - 3 2. Sheet: ASTM B209. B. Stainless St

12、eel: ASTM A167, Type 302 or 304. C. Galvanized Repair Compound: Mil. Spec MIL-P-21035. D. Primer: Fed. Spec. TT-P-645. E. Galvanized Steel: ASTM A653. F. Steel Pipe: ASTM A53. G. Casting: ASTM A47 or A48. 2.2 FABRICATION A. Weld in accordance with AWS applicable code. B. Fire Rated Shutter: 1. Integ

13、ral counter, shutter, and frame type unit for installation with hood and fascia, sloping top, related accessories and components, and automation closing by fusible link. 2. Comply with NFPA 80. The counter shall have Underwriters Laboratories Inc., or other nationally recognized laboratory label for

14、 Class / B / and / C / opening as shown. 3. Construct for / surface mounted / and / recessed / installation. 4. Construct of / galvanized steel / and / stainless steel / on exposed to view components except counter. SPEC WRITER NOTE: Use stainless steel counter with painted galvanized steel curtain,

15、 frames, and hood. 5. Counter: Minimum 2 mm (0.0747-inch) thick stainless steel with flush closed soffits and ends. 6. Curtain: a. Flat type slats, approximately 32 mm (1 1/4-inches) wide. b. Bottom bar equipped with recessed flush handles, recessed slide bolt on one end, key operated cylinder lock

16、on other end and a continuous flexible seal to make contact with counter. Lock cylinder specified in Section 08 71 00, DOOR HARDWARE. 7. Hood and Fascia: Steel Sheet, formed with beads or flanges to prevent deflection. / Sloping top exposed ends, hood, and flush closures fastened as recommended by m

17、anufacturer. / 8. Frame: Frame jamb sections to include guide slots for curtain with receiver for bolts and locks and continuous closure angles. 9. Counterbalance Assembly: Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-10-11 08 33 13 - 4 a. Spring

18、barrel or shaft of steel pipe of sufficient strength to ensure deflection not exceeding 1 mm (0.03-inch) per 300 mm (1 foot) of span. b. Barrel or shaft house oil-tempered, helically wound steel spring, and rotate on grease-sealed ball or roller-bearing units. c. Spring adjustable from outside. d. B

19、rackets not less than 3 mm (0.125-inch) thick steel designed to form end closure support for head. 10. Operation: a. Manual Push-up type for curtains less than 2130 mm (7-feet) wide. / Crank operated for curtains over 2130 mm (7-feet) wide with automatic release when activated by fusible link. / b.

20、Equip shutter with an automatic closing device actuated by fusible link to release at 130 degrees F. located exposed below the ceiling on both sides of opening in accordance with NFPA No. 80. /11. Sloping Top: a. Minimum 0.6 mm (0.0239-inch) thick steel fastened to hood with sheet metal screws. b. E

21、xposed ends flush closures fastened as recommended by manufacturer. C. Non-Fire Rated Shutter: 1. Integral counter, shutter, and frame type unit for installation with hood and fascia, sloping top, and related accessories and components required for a complete working installation. 2. Construct for /

22、 surface mounted / and / recessed / installation. 3. Exposed to view components of same metal except as specified. 4. Counter: 2 mm (0.0747-inch) thick stainless steel with flush closed soffits and ends. 5. Frame: Minimum 1.5 mm (0.0598-inch) thick steel jamb sections formed to include guide slots f

23、or curtain with receiver for bolts and locks and continuous closure angles. 6. Counterbalance Assembly: a. Spring barrel or shaft of steel pipe of sufficient strength to ensure deflection not exceeding 1 mm (0.03 inch) per 300 mm (1-foot) of span. b. Barrel or shaft house oil-tempered, helically wou

24、nd steel spring, and rotate on grease-sealed ball or roller bearings. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-10-11 08 33 13 - 5 c. Springs adjustable from outside. 7. Brackets: 3 mm (1/8-inch) thick steel plate designed to form end closure s

25、upport for hood. 8. Operation: Manual Push-up type for curtains less than 2130 mm (7-feet) wide. / Crank operated for curtains over 2130 mm (7-feet) wide /. 9. Curtain: a. Flat type slats approximately 32 mm (1-1/4-inches) wide. b. Bottom bar, equipped with recessed flush handles, recessed slide bol

26、ts for locking on one end, key operated cylinder lock on other end, and a continuous flexible seal to make tight contact with counter. Lock cylinder specified in Section 08 71 00, DOOR HARDWARE. 10. Hoods: Formed with beads or flanges to prevent deflection. / Sloping tops exposed ends and flush clos

27、ures. Fastened to hood with sheet metal screws as recommended by manufacturer. / 11. Prime Painted Galvanized Steel Shutters: a. Manufactures standard shop coat of light colored rust inhibitive prime paint after fabrication. b. Curtain minimum (0.0299-inch) thick galvanized steel. c. Sloping top / H

28、ood and Fascia: Minimum (0.0239-inch) thick galvanized steel. d. Frames: Galvanized Steel. e. Counter: Stainless steel. 12. Aluminum Shutter: a. Curtain: Extruded aluminum, minimum 1.3 mm (0.050-inch) thick, with extruded aluminum bottom angle or bars. b. / Sloping Top / Hood and Fascia: Minimum 1 m

29、m (0.040-inch) thick, sheet aluminum or 0.6 mm (0.0239-inch) thick stainless steel. c. Frames: Stainless steel. d. Counter: Stainless steel. 13. Stainless Steel Shutter: a. Curtain: 0.8 mm (0.0299-inch) thick stainless steel, with stainless steel bottom angles or bar. b. / Sloping top / Hood and Fas

30、cia: Stainless steel. c. Frames: Stainless steel. d. Counter: Stainless steel. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-10-11 08 33 13 - 6 2.3 FINISH A. Galvanized Steel: 1. Shop prime painted per NAAMM AMP 501 and 504. 2. Finish painted under

31、 Section 09 91 00, PAINTING. SPEC WRITER NOTE: Coordinate with Section 09 06 00, SCHEDULE FOR FINISHES for finish on aluminum. Preferred clear coating. B. Aluminum: 1. Finish in accordance with NAAMM AMP 500 and 501 or 504. 2. Chemically etched medium matte, with clear anodic coating, AA-C-22A41. Cl

32、ass II Architectural, 0.06 mm (0.4 mils) thick (AMP 501). Class II Architectural, 0.06 mm (0.4 mils) thick. (AMP 501). /3. Chemically etched medium matte with colored anode coating, AA-C22A42 or AA-C22A44 electrolytically deposited metallic compound) integrally colored coating, Class II, Architectur

33、al, 0.4 mils thick /. (AMP 501) /4. Fluorocarbon Finish: AAMA 605 (AMP 504) /. C. Stainless Steel: Mechanical finish No. 4 in accordance with NAAMM AMP 500 and AMP 503. PART 3 - EXECUTION 3.1 INSTALLATION A. Install in accordance with approved shop drawings and manufacturers instructions. B. Locate

34、anchors and inserts for guides, brackets, supports, hardware, and other accessories and components accurately. C. Securely attach guides to adjoining construction with not less than 10 mm (3/8-inch) diameter bolts, spaced near each end and not over 600 mm (24 inches) apart. 1. Use fasteners conformi

35、ng to ASTM F468 and F593. 2. Use stainless steel bolts with aluminum or stainless steal. 3. Use toggle bolts to frame walls or hollow masonry. 4. Use expansion bolts in solid masonry or concrete. 3.2 REPAIR Repair damaged zinc-coated surfaces by applying galvanized repair compound in accordance with

36、 the manufacturers directions. 3.3 PROTECTION A. Isolate aluminum in contact with or fastened to dissimilar metal other than stainless steel, white bronze or other metals compatible with Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-10-11 08 33 13

37、- 7 aluminum by painting the dissimilar or aluminum with a coat of TT-P-645 primer, or by placing an approved caulking compound, or a non-absorptive tape, or gasket between the aluminum and dissimilar metal. B. Paint aluminum in contact with masonry or concrete with a coat of TT-P-645. 3.4 ADJUSTING AND CLEANING A. Lubricate properly, adjust and demonstrate, to operate freely and as specified. B. Clean upon completion. - - - E N D - - - Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • EN 868-4-2017 en Packaging for terminally sterilized medical devices - Part 4 Paper bags - Requirements and test methods《最终灭菌医疗器械的包装-第4部分 纸袋-要求和试验方法》.pdf EN 868-4-2017 en Packaging for terminally sterilized medical devices - Part 4 Paper bags - Requirements and test methods《最终灭菌医疗器械的包装-第4部分 纸袋-要求和试验方法》.pdf
  • EN 868-5-2009 en Packaging for terminally sterilized medical devices - Part 5 Sealable pouches and reels of porous materials and plastic film construction - Requirements and test m.pdf EN 868-5-2009 en Packaging for terminally sterilized medical devices - Part 5 Sealable pouches and reels of porous materials and plastic film construction - Requirements and test m.pdf
  • EN 868-6-2009 2500 Packaging for terminally sterilized medical devices - Part 6 Paper for low temperature sterilization processes - Requirements and test methods《灭菌医疗装置的包装 第6部分 低温灭.pdf EN 868-6-2009 2500 Packaging for terminally sterilized medical devices - Part 6 Paper for low temperature sterilization processes - Requirements and test methods《灭菌医疗装置的包装 第6部分 低温灭.pdf
  • EN 868-6-2017 en Packaging for terminally sterilized medical devices - Part 6 Paper for low temperature sterilization processes - Requirements and test methods《最终灭菌医疗器械的包装-第6部分 低温灭.pdf EN 868-6-2017 en Packaging for terminally sterilized medical devices - Part 6 Paper for low temperature sterilization processes - Requirements and test methods《最终灭菌医疗器械的包装-第6部分 低温灭.pdf
  • EN 868-7-2009 7500 Packaging for terminally sterilized medical devices - Part 7 Adhesive coated paper for low temperature sterilization processes - Requirements and test methods《灭菌.pdf EN 868-7-2009 7500 Packaging for terminally sterilized medical devices - Part 7 Adhesive coated paper for low temperature sterilization processes - Requirements and test methods《灭菌.pdf
  • EN 868-7-2017 en Packaging for terminally sterilized medical devices - Part 7 Adhesive coated paper for low temperature sterilization processes - Requirements and test methods《最终灭菌.pdf EN 868-7-2017 en Packaging for terminally sterilized medical devices - Part 7 Adhesive coated paper for low temperature sterilization processes - Requirements and test methods《最终灭菌.pdf
  • EN 868-8-2009 en Packaging for terminally sterilized medical devices - Part 8 Reusable sterilization containers for steam sterilizers conforming to EN 285 - Requirements and test m.pdf EN 868-8-2009 en Packaging for terminally sterilized medical devices - Part 8 Reusable sterilization containers for steam sterilizers conforming to EN 285 - Requirements and test m.pdf
  • EN 868-9-2009 en Packaging for terminally sterilized medical devices - Part 9 Uncoated nonwoven materials of polyolefines - Requirements and test methods《灭菌医疗装置的包装 第9部分 聚烯烃非包覆非织物材料.pdf EN 868-9-2009 en Packaging for terminally sterilized medical devices - Part 9 Uncoated nonwoven materials of polyolefines - Requirements and test methods《灭菌医疗装置的包装 第9部分 聚烯烃非包覆非织物材料.pdf
  • EN 869-2006 en Safety of machinery - Safety requirements for pressure metal diecasting units (Incorporates Amendment A1 2009)《高压金属压模铸造组件的安全要求 包含修改件A1-2009》.pdf EN 869-2006 en Safety of machinery - Safety requirements for pressure metal diecasting units (Incorporates Amendment A1 2009)《高压金属压模铸造组件的安全要求 包含修改件A1-2009》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1