1、11-11 10 21 16 - 1 SECTION 10 21 16 SHOWER AND DRESSING COMPARTMENTS SPEC WRITER NOTES: 1. Delete between / - / to project. Also delete any other item or paragraph not applicable in the section and renumber the paragraphs. 2. See 40 CFR 247 for guidelines on the use of recycled materials. PART 1 - G

2、ENERAL 1.1 DESCRIPTION This section covers prefabricated shower cabinet / and dressing booth partitions /. 1.2 RELATED WORK A. Color of baked enamel finish and color of terrazzo receptor of shower cabinet: Section 09 06 00, SCHEDULE FOR FINISHES. B. Wood seats and seat supports: Section 06 20 00, FI

3、NISH CARPENTRY. 1.3 SUBMITTALS A. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES. B. Samples: Prime coat of paint on 300 mm (6 inch) square of metal and baked enamel finish coat over half of same. C. Manufacturers Literature and Data: Shower cabinet / and dressi

4、ng booth partitions /, indicating all hardware and fittings, material and finish. D. Shop Drawings: Shower cabinet / and dressing booth partitions /, showing 1/2 scale construction and installation details. E. Manufacturers Certificates: Zinc-Coating: Certificate, attesting that zinc-coatings confor

5、m to specified requirements. Flame spread rating is Class C for plastic shower units. 1.4 APPLICABLE PUBLICATIONS A. The publications listed below form a part of this specification to the extent referenced. The publications are referenced in the text by the basic designation only. B. American Societ

6、y of Mechanical Engineers (ASME): A112.18.1-05 . Plumbing Fixture Fittings C. Commercial Item Descriptions (CID): A-A-60003 Partitions, Toilet, Complete D. Code of Federal Regulations (CFR): 40 CFR 247 . Comprehensive Procurement Guidelines for Products Containing Recovered Materials Provided by IHS

7、Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-11-11 10 21 16 - 2 PART 2 - PRODUCTS 2.1 DRESSING BOOTH PARTITIONS A. Shall be made of materials and construction similar to requirements of CID A-A-60003, Type I, Style C (overhead braced). Provide each dressing boot

8、h with two double hook, chromium plated coat hooks, one located 75 mm (3 inches) from top edge at middle of each partition. Provide chromium plated or corrosion-resisting steel curtain rod and roller type chromium plated curtain hooks, one for each 100 mm (four inch) width of each dressing booth ope

9、ning, plus one. B. Curtains will be furnished by Government. Drill partitions for through-bolting of wood seat supports. Templates for drilling will be provided by suppliers of wood seats. Partitions shall have concealed, taped reinforcement for attachment of coat hooks by machine screws. Reinforce

10、partitions to receive wood seats. 2.2 SHOWER CABINETS A. /Baked enamel steel cabinets and terrazzo receptors. / Single plastic unit complete with receptor. / Contain recycled materials as per 40 CFR 247. B. Cabinets shall be 940 mm (37 inches) square and be complete with chromium plated or corrosion

11、-resisting steel curtain rod and soap dish. / Plastic shower units shall have a Class C flame spread rating. / Die cast zinc alloy handles for valves are not acceptable. / 2.3 FINISHES Finish 1, baked enamel finish on steel dressing booth partitions and shower cabinets. Zinc - coating on steel sheet

12、s shall be equivalent to G90. PART 3 - EXECUTION 3.1 INSTALLATION A. General: Install dressing booth partitions and shower cabinets in rigid, substantial manner, straight, plumb and with all horizontal lines level. Through - bolting shall be with hex-bolts. Evidence of drilling, cutting and fitting

13、shall be concealed in finish work. Clean finished surfaces and leave free of imperfections. B. Panels and Pilasters: Support each panel and pilaster abutting building walls near top and bottom by stirrup supports secured to partitions with sex-bolts. Secure stirrup supports to building construction

14、with two anchoring devices for each stirrup. Headrails shall be clamped on or set into top of each pilaster and secured to building walls. Secure clamps to pilasters with two through-bolts to each clamp. When set into pilasters, through-bolt headrails to pilasters. Support headrails on Provided by I

15、HSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-11-11 10 21 16 - 3 wall flange fittings secured to building walls with minimum of two anchor bolts to each flange fitting. C. Shower Cabinets: Make connections to water supplies and drains watertight. When mounted in wall recesses, caulk joint between cabinet and adjacent wall construction. - - - E N D - - - Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-