IEC 61674-2012 Medical electrical equipment - Dosimeters with ionization chambers and or semiconductor detectors as used in X-ray diagnostic imaging《医用电气设备.用X射线诊断成像中带电离室和 或半导体探测器的剂量仪》.pdf

上传人:explodesoak291 文档编号:1236673 上传时间:2019-08-24 格式:PDF 页数:78 大小:1.29MB
下载 相关 举报
IEC 61674-2012 Medical electrical equipment - Dosimeters with ionization chambers and or semiconductor detectors as used in X-ray diagnostic imaging《医用电气设备.用X射线诊断成像中带电离室和 或半导体探测器的剂量仪》.pdf_第1页
第1页 / 共78页
IEC 61674-2012 Medical electrical equipment - Dosimeters with ionization chambers and or semiconductor detectors as used in X-ray diagnostic imaging《医用电气设备.用X射线诊断成像中带电离室和 或半导体探测器的剂量仪》.pdf_第2页
第2页 / 共78页
IEC 61674-2012 Medical electrical equipment - Dosimeters with ionization chambers and or semiconductor detectors as used in X-ray diagnostic imaging《医用电气设备.用X射线诊断成像中带电离室和 或半导体探测器的剂量仪》.pdf_第3页
第3页 / 共78页
IEC 61674-2012 Medical electrical equipment - Dosimeters with ionization chambers and or semiconductor detectors as used in X-ray diagnostic imaging《医用电气设备.用X射线诊断成像中带电离室和 或半导体探测器的剂量仪》.pdf_第4页
第4页 / 共78页
IEC 61674-2012 Medical electrical equipment - Dosimeters with ionization chambers and or semiconductor detectors as used in X-ray diagnostic imaging《医用电气设备.用X射线诊断成像中带电离室和 或半导体探测器的剂量仪》.pdf_第5页
第5页 / 共78页
点击查看更多>>
资源描述

1、 IEC 61674 Edition 2.0 2012-11 INTERNATIONAL STANDARD NORME INTERNATIONALE Medical electrical equipment Dosimeters with ionization chambers and/or semiconductor detectors as used in X-ray diagnostic imaging Appareils lectromdicaux Dosimtres chambres dionisation et/ou dtecteurs semi-conducteurs utili

2、ss en imagerie de diagnostic rayonnement X IEC61674:2012 THIS PUBLICATION IS COPYRIGHT PROTECTED Copyright 2012 IEC, Geneva, Switzerland All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, i

3、ncluding photocopying and microfilm, without permission in writing from either IEC or IECs member National Committee in the country of the requester. If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication, please contact the address bel

4、ow or your local IEC member National Committee for further information. Droits de reproduction rservs. Sauf indication contraire, aucune partie de cette publication ne peut tre reproduite ni utilise sous quelque forme que ce soit et par aucun procd, lectronique ou mcanique, y compris la photocopie e

5、t les microfilms, sans laccord crit de la CEI ou du Comit national de la CEI du pays du demandeur. Si vous avez des questions sur le copyright de la CEI ou si vous dsirez obtenir des droits supplmentaires sur cette publication, utilisez les coordonnes ci-aprs ou contactez le Comit national de la CEI

6、 de votre pays de rsidence. IEC Central Office Tel.: +41 22 919 02 11 3, rue de Varemb Fax: +41 22 919 03 00 CH-1211 Geneva 20 infoiec.ch Switzerland www.iec.ch About the IEC The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes Internatio

7、nal Standards for all electrical, electronic and related technologies. About IEC publications The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the latest edition, a corrigenda or an amendment might have been published. Useful links: I

8、EC publications search - www.iec.ch/searchpub The advanced search enables you to find IEC publications by a variety of criteria (reference number, text, technical committee,). It also gives information on projects, replaced and withdrawn publications. IEC Just Published - webstore.iec.ch/justpublish

9、ed Stay up to date on all new IEC publications. Just Published details all new publications released. Available on-line and also once a month by email. Electropedia - www.electropedia.org The worlds leading online dictionary of electronic and electrical terms containing more than 30 000 terms and de

10、finitions in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical Vocabulary (IEV) on-line. Customer Service Centre - webstore.iec.ch/csc If you wish to give us your feedback on this publication or need further assistance, please contact

11、 the Customer Service Centre: csciec.ch. A propos de la CEI La Commission Electrotechnique Internationale (CEI) est la premire organisation mondiale qui labore et publie des Normes internationales pour tout ce qui a trait llectricit, llectronique et aux technologies apparentes. A propos des publicat

12、ions CEI Le contenu technique des publications de la CEI est constamment revu. Veuillez vous assurer que vous possdez ldition la plus rcente, un corrigendum ou amendement peut avoir t publi. Liens utiles: Recherche de publications CEI - www.iec.ch/searchpub La recherche avance vous permet de trouver

13、 des publications CEI en utilisant diffrents critres (numro de rfrence, texte, comit dtudes,). Elle donne aussi des informations sur les projets et les publications remplaces ou retires. Just Published CEI - webstore.iec.ch/justpublished Restez inform sur les nouvelles publications de la CEI. Just P

14、ublished dtaille les nouvelles publications parues. Disponible en ligne et aussi une fois par mois par email. Electropedia - www.electropedia.org Le premier dictionnaire en ligne au monde de termes lectroniques et lectriques. Il contient plus de 30 000 termes et dfinitions en anglais et en franais,

15、ainsi que les termes quivalents dans les langues additionnelles. Egalement appel Vocabulaire Electrotechnique International (VEI) en ligne. Service Clients - webstore.iec.ch/csc Si vous dsirez nous donner des commentaires sur cette publication ou si vous avez des questions contactez-nous: csciec.ch.

16、 IEC 61674 Edition 2.0 2012-11 INTERNATIONAL STANDARD NORME INTERNATIONALE Medical electrical equipment Dosimeters with ionization chambers and/or semiconductor detectors as used in X-ray diagnostic imaging Appareils lectromdicaux Dosimtres chambres dionisation et/ou dtecteurs semi-conducteurs utili

17、ss en imagerie de diagnostic rayonnement X INTERNATIONAL ELECTROTECHNICAL COMMISSION COMMISSION ELECTROTECHNIQUE INTERNATIONALE W ICS 11.040.50 PRICE CODE CODE PRIX ISBN 978-2-83220-510-5 Registered trademark of the International Electrotechnical Commission Marque dpose de la Commission Electrotechn

18、ique Internationale Warning! Make sure that you obtained this publication from an authorized distributor. Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agr. 2 61674 IEC:2012 CONTENTS FOREWORD . 4 INTRODUCTION . 6 1 Scope and object 7 1.1 Scope 7 1.2 Obje

19、ct . 7 2 Normative references . 7 3 Terms and definitions . 8 4 General requirements . 15 4.1 Performance requirements 15 4.2 REFERENCE VALUES and STANDARD TEST VALUES 15 4.3 General test conditions 16 4.3.1 STANDARD TEST CONDITIONS 16 4.3.2 Statistical fluctuations 17 4.3.3 STABILIZATION TIME . 17

20、4.3.4 Adjustments during test . 17 4.3.5 Batteries 17 4.4 Constructional requirements as related to performance . 18 4.4.1 Components 18 4.4.2 Display 18 4.4.3 Indication of battery condition 18 4.4.4 Indication of polarizing voltage failure 18 4.4.5 Over-ranging . 18 4.4.6 MEASURING ASSEMBLIES with

21、 multiple DETECTOR ASSEMBLIES . 19 4.4.7 Radioactive STABILITY CHECK DEVICE . 19 4.5 UNCERTAINTY of measurement . 20 5 Limits of PERFORMANCE CHARACTERISTICS 20 5.1 Linearity 20 5.2 Repeatability . 20 5.2.1 General . 20 5.2.2 Repeatability in the ATTENUATED BEAM 20 5.2.3 Repeatability in the UNATTENU

22、ATED BEAM 21 5.3 RESOLUTION of reading 21 5.4 STABILIZATION TIME . 21 5.5 Effect of pulsed radiation on AIR KERMA and AIR KERMA LENGTH PRODUCT measurements . 22 5.6 Reset on AIR KERMA and AIR KERMA LENGTH PRODUCT ranges 22 5.7 Effects of LEAKAGE CURRENT . 22 5.7.1 AIR KERMA RATE measurements 22 5.7.

23、2 AIR KERMA and AIR KERMA LENGTH PRODUCT measurements . 22 5.8 Stability . 23 5.8.1 Long term stability . 23 5.8.2 Accumulated dose stability 23 5.9 Measurements with a radioactive STABILITY CHECK DEVICE 23 6 LIMITS OF VARIATION for effects of INFLUENCE QUANTITIES 24 6.1 General . 24 6.2 Energy depe

24、ndence of RESPONSE 24 61674 IEC:2012 3 6.3 AIR KERMA RATE dependence of AIR KERMA and AIR KERMA LENGTH PRODUCT measurements . 25 6.3.1 MEASURING ASSEMBLY . 25 6.3.2 IONIZATION CHAMBER Recombination losses . 26 6.4 Dependence of DETECTOR RESPONSE on angle of incidence of radiation . 26 6.4.1 Non-CT d

25、etectors 26 6.4.2 CT DETECTORS . 26 6.5 Operating voltage 27 6.5.1 Mains-operated DOSIMETERS 27 6.5.2 Battery-operated DOSIMETERS 27 6.5.3 Mains rechargeable, battery-operated DOSIMETERS 27 6.6 Air pressure . 28 6.7 Air pressure EQUILIBRATION TIME of the RADIATION DETECTOR . 28 6.8 Temperature and h

26、umidity . 28 6.9 Electromagnetic compatibility 29 6.9.1 ELECTROSTATIC DISCHARGE . 29 6.9.2 Radiated electromagnetic fields . 29 6.9.3 CONDUCTED DISTURBANCES induced by bursts and radio frequencies 30 6.9.4 Voltage dips, short interruptions and voltage VARIATIONS . 30 6.10 Field size . 30 6.11 EFFECT

27、IVE LENGTH and spatial uniformity of RESPONSE of CT DOSIMETERS . 30 7 Marking 31 7.1 DETECTOR ASSEMBLY 31 7.2 MEASURING ASSEMBLY 31 7.3 Radioactive STABILITY CHECK DEVICE . 31 8 ACCOMPANYING DOCUMENTS . 31 Annex A (informative) COMBINED STANDARD UNCERTAINTY for dosimeter performance 33 Index of defi

28、ned terms 34 Table 1 REFERENCE and STANDARD TEST CONDITIONS . 16 Table 2 Number of readings required to detect true differences (95 % confidence level) between two sets of instrument readings . 17 Table 3 Maximum values for the COEFFICIENT OF VARIATION, vmax, for measurements in the attenuated beam

29、 21 Table 4 Maximum values for the COEFFICIENT OF VARIATION, vmax, for measurements in the unattenuated beam . 21 Table 5 LIMITS OF VARIATION for the effects of INFLUENCE QUANTITIES . 24 Table 6 Climatic conditions 28 Table A.1 Estimation of COMBINED STANDARD UNCERTAINTY for dosimeter performance 3

30、3 4 61674 IEC:2012 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ MEDICAL ELECTRICAL EQUIPMENT DOSIMETERS WITH IONIZATION CHAMBERS AND/OR SEMICONDUCTOR DETECTORS AS USED IN X-RAY DIAGNOSTIC IMAGING FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardi

31、zation comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes Interna

32、tional Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate i

33、n this preparatory work. International, governmental and non-governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the

34、 two organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees. 3) IEC Publications have

35、 the form of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any misin

36、terpretation by any end user. 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications. Any divergence between any IEC Publication and the corresponding nation

37、al or regional publication shall be clearly indicated in the latter. 5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any services ca

38、rried out by independent certification bodies. 6) All users should ensure that they have the latest edition of this publication. 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its technical committees and IEC National C

39、ommittees for any personal injury, property damage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications. 8) Attention is draw

40、n to the Normative references cited in this publication. Use of the referenced publications is indispensable for the correct application of this publication. 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights. IEC shall not

41、be held responsible for identifying any or all such patent rights. International Standard IEC 61674 has been prepared by subcommittee 62C: Equipment for radiotherapy, nuclear medicine and radiation dosimetry, of IEC technical committee 62: Electrical equipment in medical practice. This second editio

42、n cancels and replaces the first edition of IEC 61674. This edition constitutes a technical revision. The text of this standard is based on the following documents: FDIS Report on voting 62C/551/FDIS 62C/555/RVD Full information on the voting for the approval of this standard can be found in the rep

43、ort on voting indicated in the above table. 61674 IEC:2012 5 This publication has been drafted in accordance with the ISO/IEC Directives, Part 2. In this standard, the following print types are used: Requirements and definitions: roman type. Test specifications: italic type. Informative material app

44、earing outside of tables, such as notes, examples and references: in smaller type. Normative text of tables is also in a smaller type. TERMS DEFINED IN CLAUSE 3 OF IEC 60601-1, IN THIS PARTICULAR STANDARD OR AS NOTED: SMALL CAPITALS. The verbal forms used in this standard conform to usage described

45、in Annex H of the ISO/IEC Directives, Part 2. For the purposes of this standard, the auxiliary verb: “shall” means that compliance with a requirement or a test is mandatory for compliance with this standard; “should” means that compliance with a requirement or a test is recommended but is not mandat

46、ory for compliance with this standard; “may” is used to describe a permissible way to achieve compliance with a requirement or test. The committee has decided that the contents of this publication will remain unchanged until the stability date indicated on the IEC web site under “http:/webstore.iec.

47、ch“ in the data related to the specific publication. At this date, the publication will be reconfirmed, withdrawn, replaced by a revised edition, or amended. 6 61674 IEC:2012 INTRODUCTION Diagnostic radiology is the largest contributor to man-made IONIZING RADIATION to which the public is exposed. T

48、he reduction in the exposure received by PATIENTS undergoing medical radiological examinations or procedures has therefore become a central issue in recent years. The PATIENT dose will be minimized when the X-ray producing equipment is correctly adjusted for image quality and radiation output. These

49、 adjustments require that the routine measurement of AIR KERMA, AIR KERMA LENGTH PRODUCT and/or AIR KERMA RATE be made accurately. The equipment covered by this standard plays an essential part in achieving the required accuracy. The DOSIMETERS used for adjustment and control measurements must be of satisfactory quality and must therefore fulfil the special requirements laid down in this standard. 6167

展开阅读全文
相关资源
  • IEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdfIEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdf
  • IEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdfIEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdf
  • IEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdfIEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdf
  • IEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdfIEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdf
  • IEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdfIEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdf
  • IEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdfIEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdf
  • IEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdfIEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdf
  • IEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdfIEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdf
  • IEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdfIEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdf
  • IEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdfIEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > IEC

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1