IEC 61970-407-2007 Energy management system application program interface (EMS-API) - Part 407 Time series data access (TSDA)《能量管理系统应用程序接口(EMS-API).第407部分 时序数据存取(TSDA)》.pdf

上传人:medalangle361 文档编号:1237006 上传时间:2019-08-24 格式:PDF 页数:26 大小:879.40KB
下载 相关 举报
IEC 61970-407-2007 Energy management system application program interface (EMS-API) - Part 407 Time series data access (TSDA)《能量管理系统应用程序接口(EMS-API).第407部分 时序数据存取(TSDA)》.pdf_第1页
第1页 / 共26页
IEC 61970-407-2007 Energy management system application program interface (EMS-API) - Part 407 Time series data access (TSDA)《能量管理系统应用程序接口(EMS-API).第407部分 时序数据存取(TSDA)》.pdf_第2页
第2页 / 共26页
IEC 61970-407-2007 Energy management system application program interface (EMS-API) - Part 407 Time series data access (TSDA)《能量管理系统应用程序接口(EMS-API).第407部分 时序数据存取(TSDA)》.pdf_第3页
第3页 / 共26页
IEC 61970-407-2007 Energy management system application program interface (EMS-API) - Part 407 Time series data access (TSDA)《能量管理系统应用程序接口(EMS-API).第407部分 时序数据存取(TSDA)》.pdf_第4页
第4页 / 共26页
IEC 61970-407-2007 Energy management system application program interface (EMS-API) - Part 407 Time series data access (TSDA)《能量管理系统应用程序接口(EMS-API).第407部分 时序数据存取(TSDA)》.pdf_第5页
第5页 / 共26页
点击查看更多>>
资源描述

1、 IEC 61970-407Edition 1.0 2007-08INTERNATIONAL STANDARD Energy management system application program interface (EMS-API) Part 407: Time Series Data Access (TSDA) IEC61970-407:2007(E) THIS PUBLICATION IS COPYRIGHT PROTECTED Copyright 2007 IEC, Geneva, Switzerland All rights reserved. Unless otherwise

2、 specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or IECs member National Committee in the country of the requester. If you have any question

3、s about IEC copyright or have an enquiry about obtaining additional rights to this publication, please contact the address below or your local IEC member National Committee for further information. IEC Central Office 3, rue de Varemb CH-1211 Geneva 20 Switzerland Email: inmailiec.ch Web: www.iec.ch

4、About the IEC The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes International Standards for all electrical, electronic and related technologies. About IEC publications The technical content of IEC publications is kept under constant re

5、view by the IEC. Please make sure that you have the latest edition, a corrigenda or an amendment might have been published. Catalogue of IEC publications: www.iec.ch/searchpub The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,). It

6、also gives information on projects, withdrawn and replaced publications. IEC Just Published: www.iec.ch/online_news/justpub Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available on-line and also by email. Electropedia: www.electrop

7、edia.org The worlds leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical Vocabulary online. Customer Service Centre: www.ie

8、c.ch/webstore/custserv If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service Centre FAQ or contact us: Email: csciec.ch Tel.: +41 22 919 02 11 Fax: +41 22 919 03 00 IEC 61970-407Edition 1.0 2007-08INTERNATIONAL STANDARD Energy manageme

9、nt system application program interface (EMS-API) Part 407: Time Series Data Access (TSDA) INTERNATIONAL ELECTROTECHNICAL COMMISSION SICS 33.200 PRICE CODEISBN 2-8318-9253-8 2 61970-407 IEC:2007(E) CONTENTS FOREWORD.3 INTRODUCTION.5 1 Scope.6 2 Normative references .7 3 Terms, definitions and identi

10、fication conventions 7 3.1 Terms and definitions 7 3.2 Conventions 7 4 CIS Specification7 4.1 Background (informative) 7 4.2 Historian use case (informative) 8 4.3 Data model10 4.4 Messages (normative) .13 4.5 Interface (normative) .13 4.5.1 Objects and interfaces.13 4.5.2 Server and Session interfa

11、ces .16 4.5.3 Management interfaces .17 4.5.4 Browse interfaces17 4.5.5 IO interfaces18 4.5.6 Client interfaces 20 4.6 Mapping of TSDA 20 Figure 1 Control system structure 9 Figure 2 TSDA server and clients.10 Figure 3 Data subscription .10 Figure 4 TSDA data model.11 Figure 5 TSDA objects and inter

12、faces 14 Figure 6 Typical Interaction between the TSDA objects16 61970-407 IEC:2007(E) 3 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ ENERGY MANAGEMENT SYSTEM APPLICATION PROGRAM INTERFACE (EMS-API) Part 407: Time Series Data Access (TSDA) FOREWORD 1) The International Electrotechnical Commission (IE

13、C) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in additio

14、n to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested

15、 in the subject dealt with may participate in this preparatory work. International, governmental and non-governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with co

16、nditions determined by agreement between the two organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested IEC N

17、ational Committees. 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsible for the

18、 way in which they are used or for any misinterpretation by any end user. 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications. Any divergence between any

19、IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter. 5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any equipment declared to be in conformity with an IEC Publication. 6) All users shoul

20、d ensure that they have the latest edition of this publication. 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its technical committees and IEC National Committees for any personal injury, property damage or other damag

21、e of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications. 8) Attention is drawn to the Normative references cited in this publication. Use of t

22、he referenced publications is indispensable for the correct application of this publication. 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights. IEC shall not be held responsible for identifying any or all such patent rights

23、. International Standard IEC 61970-407 has been prepared by IEC Technical Committee 57: Power systems management and associated information exchange. The text of this standard is based on the following documents: FDIS Report on voting 57/889/FDIS 57/908/RVD Full information on the voting for the app

24、roval of this standard can be found in the report on voting indicated in the above table. A list of all parts of the IEC 61970 series, under the general title Energy Management System Application Program Interface (EMS-API), can be found on the IEC website. 4 61970-407 IEC:2007(E) The committee has

25、decided that the contents of this publication will remain unchanged until the maintenance result date indicated on the IEC web site under “http:/webstore.iec.ch“ in the data related to the specific publication. At this date, the publication will be reconfirmed; withdrawn; replaced by a revised editi

26、on, or amended. A bilingual version of this publication may be issued at a later date. 61970-407 IEC:2007(E) 5 INTRODUCTION This part of IEC 61970 is part of the IEC 61970 series that defines Application Program Interfaces (APIs) for an Energy Management System (EMS). The IEC 61970-4XX and IEC 61970

27、-5XX series documents comprise Component Interface Specifications (CISs). The IEC 61970-4XX series CIS are specified as Platform Independent Models (PIMs), which means they are independent of the underlying technology used to implement them. PIM specifications are also referred to as Level 1 specifi

28、cations. The IEC 61970-5XX series CIS, on the other hand, are specified as Platform Specific Models (PSMs). PSM specifications are also referred to as Level 2 specifications. IEC 61970-4XX CISs specify the functional requirements for interfaces that a component (or application) should implement to e

29、xchange information with other components (or applications) and/or to access publicly available data in a standard way. The component interfaces describe the specific event types and message contents that can be used by applications for this purpose. IEC 61970-407 specifies an interface for the effi

30、cient transfer of time series data in a distributed environment. Small amounts of data are transferred with short delay but also large amounts of data are transferred in short time but with possibly longer delay. Replay of time series data is also supported. This is a typical requirement for a SCADA

31、 system that acts as a real time data provider to other sub-systems. Other systems than SCADA may also benefit from the characteristics of TSDA. When short delay times as well as bulk data transfer is required TSDA is a good fit. These component interface specifications refer to entity objects for t

32、he power system domain that is defined in the IEC 61970-3XX series, including IEC 61970-301. 6 61970-407 IEC:2007(E) ENERGY MANAGEMENT SYSTEM APPLICATION PROGRAM INTERFACE (EMS-API) Part 407: Time Series Data Access (TSDA) 1 Scope The IEC 61970-407 Time Series Data Access (TSDA) specification specif

33、ies a generalized interface for efficient exchange of data. The specification takes into account the latencies caused by a Local Area Network (LAN) providing efficient data exchange also over Local Area Networks. IEC 61970-407 is derived from the Object Management Group (OMG) Historical Data Access

34、from Industrial Systems (HDAIS) specification. OMG HDAIS relies on the OMG Data Access Facility (DAF) and OPC Historical Data Access (HDA) specifications. OMG HDAIS is a Platform Specific Model (PSM) with CORBA as the platform and OPC HDA is a PSM with Microsoft COM as the platform. The IEC 61970-40

35、7 specification describes the functionality of these PSMs in a technology independent way (i.e., as a Platform Independent Model (PIM). Hence, it explains the functionality to a level that can be used to create additional PSMs or be an introduction to existing PSMs, i.e. HDAIS and OPC HDA. Implement

36、ers wanting an introduction to OMG HDAIS and OPC HDA should read these documents. The TSDA interface is intended to interoperate with other IEC 61970 based interfaces. Hence, it is possible to use information retrieved from other interface to access the same information using this interface, for exa

37、mple: object identifiers, attribute names or identifiers, class names or identifiers. Subclause 4.6 provides a generic mapping for the CIM classes and attributes. The way data is organized in a server implementing the TSDA interface can be seen by using the browse interfaces for data and meta data.

38、It is also possible to use the data access interface directly without using the browse interfaces if the client has an a priori knowledge of object, class and attribute identifiers. Object identifiers may be retrieved using data from other interfaces, for example a CIMXML file or the IEC 61970-404 i

39、nterface. Information on what classes and attributes are available will be described in IEC 61970-45X documents, for example historical SCADA data, historical State Estimator results etc. IEC 61970-1 provides the EMS-API reference model upon which this standard is based. In that reference model, the

40、 terminology used in this part of IEC 61970 is introduced and the role of the CIS is explained. IEC 61970-401 provides an overview and framework for the CIS (IEC 61970-4XX) standards. The mapping of IEC 61970-407 to implementation specific technologies or PSMs is further described in a separate seri

41、es of documents, i.e. the future IEC 61970-5XX. For actual implementations the future IEC 61970-5XX, OMG HDAIS, OMG DAF or OPC HDA are used. 61970-407 IEC:2007(E) 7 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references,

42、 only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 61970-1, Energy management system application program interface (EMS-API) Part 1: Guidelines and general requirements IEC/TS 61970-2, Energy management syste

43、m application program interface (EMS-API) Part 2: Glossary IEC 61970-301:2005, Energy management system application program interface (EMS-API) Part 301: Common Information Model (CIM) base IEC 61970-401, Energy management system application program interface (EMS-API) Part 401: Component Interface

44、Specification (CIS) Framework IEC 61970-402, Energy management system application program interface (EMS-API) Part 402: Component Interface Specification (CIS) - Common Services Historical Data Access from Industrial Systems (HDAIS), OMG Adopted Specification Version 1.0, dtc/2003-02-01 November 200

45、3 (Referred herein as OMG HDAIS) Utility Management System (UMS) Data Access Facility (DAF), OMG Adopted Specification, Version 2.0, formal/02-11-08, November 2002 (Referred to herein as OMG DAF) Data Acquisition from Industrial Systems (DAIS), OMG Adopted Specification Version 1.0, formal/2002-11-0

46、7 November 2002 (Referred herein as OMG DAIS) OPC Historical Data Access Custom Interface Specification, Version 1.20, OPC Foundation, December 2003 (Referred to herein as OPC HDA) 3 Terms, definitions and identification conventions 3.1 Terms and definitions For the purposes of this document, the te

47、rms and definitions given in IEC 61970-2 apply. 3.2 Conventions A convention used in this document to uniquely identify a UML attribute is to concatenate the class name and the attribute name with a period in between, for example, the attribute “id” in the class “Node” will then be named “Node.id”.

48、For attributes in sub structures multiple attribute names may be used, for example “Item.id.node_id” where the “node_id” is a part in the structure “Item.id”. 4 CIS Specification 4.1 Background (informative) For historical reasons, control systems for different industrial processes have evolved alon

49、g different lines. Control systems for power systems have evolved on a UNIX base and control systems for most other industrial processes have evolved on a Windows base. For Windows based control systems, OPC has become the dominating standard. For UNIX based systems, the DAIS/HDAIS API defined in Common Object Request Broker Architecture (CORBA) 8 61970-407 IEC:2007(E) Interface Definition Language (IDL) has been developed. DAIS/HDAIS is based on OPC to benefit from the

展开阅读全文
相关资源
  • IEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdfIEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdf
  • IEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdfIEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdf
  • IEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdfIEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdf
  • IEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdfIEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdf
  • IEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdfIEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdf
  • IEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdfIEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdf
  • IEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdfIEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdf
  • IEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdfIEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdf
  • IEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdfIEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdf
  • IEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdfIEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > IEC

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1