1、 IEC 62132-3Edition 1.0 2007-09INTERNATIONAL STANDARD NORME INTERNATIONALEIntegrated circuits Measurement of electromagnetic immunity, 150 kHz to 1 GHz Part 3: Bulk current injection (BCI) method Circuits intgrs Mesure de limmunit lectromagntique, 150 kHz 1 GHz Partie 3: Mthode dinjection de courant
2、 (BCI) IEC62132-3:2007 THIS PUBLICATION IS COPYRIGHT PROTECTED Copyright 2007 IEC, Geneva, Switzerland All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfil
3、m, without permission in writing from either IEC or IECs member National Committee in the country of the requester. If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication, please contact the address below or your local IEC member Nation
4、al Committee for further information. Droits de reproduction rservs. Sauf indication contraire, aucune partie de cette publication ne peut tre reproduite ni utilise sous quelque forme que ce soit et par aucun procd, lectronique ou mcanique, y compris la photocopie et les microfilms, sans laccord cri
5、t de la CEI ou du Comit national de la CEI du pays du demandeur. Si vous avez des questions sur le copyright de la CEI ou si vous dsirez obtenir des droits supplmentaires sur cette publication, utilisez les coordonnes ci-aprs ou contactez le Comit national de la CEI de votre pays de rsidence. IEC Ce
6、ntral Office 3, rue de Varemb CH-1211 Geneva 20 Switzerland Email: inmailiec.ch Web: www.iec.ch About the IEC The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes International Standards for all electrical, electronic and related technolo
7、gies. About IEC publications The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the latest edition, a corrigenda or an amendment might have been published. Catalogue of IEC publications: www.iec.ch/searchpub The IEC on-line Catalogue en
8、ables you to search by a variety of criteria (reference number, text, technical committee,). It also gives information on projects, withdrawn and replaced publications. IEC Just Published: www.iec.ch/online_news/justpub Stay up to date on all new IEC publications. Just Published details twice a mont
9、h all new publications released. Available on-line and also by email. Electropedia: www.electropedia.org The worlds leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions in English and French, with equivalent terms in additional languages. Als
10、o known as the International Electrotechnical Vocabulary online. Customer Service Centre: www.iec.ch/webstore/custserv If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service Centre FAQ or contact us: Email: csciec.ch Tel.: +41 22 919 02
11、 11 Fax: +41 22 919 03 00 A propos de la CEI La Commission Electrotechnique Internationale (CEI) est la premire organisation mondiale qui labore et publie des normes internationales pour tout ce qui a trait llectricit, llectronique et aux technologies apparentes. A propos des publications CEI Le con
12、tenu technique des publications de la CEI est constamment revu. Veuillez vous assurer que vous possdez ldition la plus rcente, un corrigendum ou amendement peut avoir t publi. Catalogue des publications de la CEI: www.iec.ch/searchpub/cur_fut-f.htm Le Catalogue en-ligne de la CEI vous permet deffect
13、uer des recherches en utilisant diffrents critres (numro de rfrence, texte, comit dtudes,). Il donne aussi des informations sur les projets et les publications retires ou remplaces. Just Published CEI: www.iec.ch/online_news/justpub Restez inform sur les nouvelles publications de la CEI. Just Publis
14、hed dtaille deux fois par mois les nouvelles publications parues. Disponible en-ligne et aussi par email. Electropedia: www.electropedia.org Le premier dictionnaire en ligne au monde de termes lectroniques et lectriques. Il contient plus de 20 000 termes et dfinitions en anglais et en franais, ainsi
15、 que les termes quivalents dans les langues additionnelles. Egalement appel Vocabulaire Electrotechnique International en ligne. Service Clients: www.iec.ch/webstore/custserv/custserv_entry-f.htm Si vous dsirez nous donner des commentaires sur cette publication ou si vous avez des questions, visitez
16、 le FAQ du Service clients ou contactez-nous: Email: csciec.ch Tl.: +41 22 919 02 11 Fax: +41 22 919 03 00 IEC 62132-3Edition 1.0 2007-09INTERNATIONAL STANDARD NORME INTERNATIONALEIntegrated circuits Measurement of electromagnetic immunity, 150 kHz to 1 GHz Part 3: Bulk current injection (BCI) metho
17、d Circuits intgrs Mesure de limmunit lectromagntique, 150 kHz 1 GHz Partie 3: Mthode dinjection de courant (BCI) INTERNATIONAL ELECTROTECHNICAL COMMISSION COMMISSION ELECTROTECHNIQUE INTERNATIONALE RICS 31.200 PRICE CODECODE PRIXISBN 2-8318-9320-8 2 62132-3 IEC:2007 CONTENTS FOREWORD.3 1 Scope and o
18、bject5 2 Normative references .5 3 Terms and definitions .5 4 General 5 5 Test conditions .6 5.1 General .6 5.2 Test equipment .7 5.3 Test board.7 6 Test procedure .9 6.1 Hazardous electromagnetic fields9 6.2 Calibration of forward power limitation.9 6.3 BCI test.10 6.4 BCI test set-up characterizat
19、ion procedure11 7 Test report12 Annex A (informative) Examples for test levels and frequency step selection .13 Annex B (informative) Example of BCI test board and set-up .15 Annex C (informative) Example of RF test board and set-up 18 Bibliography19 Figure 1 Principal current path when using BCI6 F
20、igure 2 Schematic diagram of BCI test set-up 7 Figure 3 Example test board, top view .8 Figure 4 Calibration set-up.10 Figure 5 BCI test procedure flowchart for each frequency step.11 Figure 6 Impedance validation test set-up11 Figure B.1 General view.15 Figure B.2 Example of top view of the test bo
21、ard .16 Figure B.3 Test board build-up.16 Figure B.4 Test board and copper fixture .17 Figure B.5 Example of a non-conductive probes support fixture .17 Figure C.1 Compact RF coupling to differential IC ports.18 Table A.1 Test severity levels 13 Table A.2 Linear frequency step 14 Table A.3 Logarithm
22、ic frequency step 14 62132-3 IEC:2007 3 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ INTEGRATED CIRCUITS MEASUREMENT OF ELECTROMAGNETIC IMMUNITY, 150 kHz TO 1 GHz Part 3: Bulk current injection (BCI) method FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization fo
23、r standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publis
24、hes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may pa
25、rticipate in this preparatory work. International, governmental and non-governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement
26、between the two organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees. 3) IEC Public
27、ations have the form of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsible for the way in which they are used or fo
28、r any misinterpretation by any end user. 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications. Any divergence between any IEC Publication and the correspon
29、ding national or regional publication shall be clearly indicated in the latter. 5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any equipment declared to be in conformity with an IEC Publication. 6) All users should ensure that they have the lates
30、t edition of this publication. 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its technical committees and IEC National Committees for any personal injury, property damage or other damage of any nature whatsoever, wheth
31、er direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications. 8) Attention is drawn to the normative references cited in this publication. Use of the referenced publications is ind
32、ispensable for the correct application of this publication. 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights. IEC shall not be held responsible for identifying any or all such patent rights. International Standard IEC 6213
33、2-3 has been prepared by subcommittee 47A: Integrated circuits, of IEC technical committee 47: Semiconductor devices. The text of this standard is based on the following documents: FDIS Report on voting 47A/773/FDIS 47A/776/RVDFull information on the voting for the approval of this standard can be f
34、ound in the report on voting indicated in the above table. This publication has been drafted in accordance with the ISO/IEC Directives, Part 2. 4 62132-3 IEC:2007 A list of all parts of the IEC 62132 series, published under the general title Integrated circuits Measurement of electromagnetic immunit
35、y, 150 kHz to 1 GHz can be found on the IEC website. The committee has decided that the contents of this publication will remain unchanged until the maintenance result date indicated on the IEC web site under “http:/webstore.iec.ch“ in the data related to the specific publication. At this date, the
36、publication will be reconfirmed, withdrawn, replaced by a revised edition, or amended. 62132-3 IEC:2007 5 INTEGRATED CIRCUITS MEASUREMENT OF ELECTROMAGNETIC IMMUNITY, 150 kHz TO 1 GHz Part 3: Bulk current injection (BCI) method 1 Scope and object This part of IEC 62132 describes a bulk current injec
37、tion (BCI) test method to measure the immunity of integrated circuits (IC) in the presence of conducted RF disturbances, e.g. resulting from radiated RF disturbances. This method only applies to ICs that have off-board wire connections e.g. into a cable harness. This test method is used to inject RF
38、 current on one or a combination of wires. This standard establishes a common base for the evaluation of semiconductor devices to be applied in equipment used in environments that are subject to unwanted radio frequency electromagnetic signals. 2 Normative references The following referenced documen
39、ts are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 62132-1:2006, Integrated circuits Measurement of electromagnetic immunity, 15
40、0 kHz to 1 GHz Part 1: General conditions and definitions 3 Terms and definitions For the purposes of this document, the terms and definitions given in IEC 62132-1 apply. 4 General The characterization of RF immunity (or susceptibility) of an integrated circuit (IC) is essential to define the optimu
41、m design of a printed circuit board, filter concepts and for further integration into an electronic system. This document defines a method for measuring the immunity of ICs to RF current induced by electromagnetic disturbance. This method is based on the bulk current injection (BCI) method used for
42、equipment and systems 1, 2, 3. The BCI method simulates the induced current as a result of direct radiated RF signals coupled onto the wires and cables of equipment and systems. In general, in electronic systems, off-board wire connections or traces on the printed circuit board act as antennas for e
43、lectromagnetic fields. Via this coupling path, these electro-magnetic fields will induce voltages and currents at the pins of the IC and may cause interference. ICs are often used in various configurations dependent on their application. In this case, immunity levels of electronic equipment are clos
44、ely linked to the ability of an IC to withstand the effects of an electromagnetic field represented. To characterize the RF immunity of an IC, the induced current level necessary to cause the ICs malfunction is measured. The malfunction may be classified from A to E according to the performance clas
45、ses defined in IEC 62132-1. 6 62132-3 IEC:2007 A principal set-up for the bulk current injection method is presented in Figure 1. Current monitoring Power injection Supportive circuitry and by-pass capacitor Injection probe Current probeIC under test DUT IdisturbanceIC controlling and monitoring Vss
46、GND IEC 1811/07 Figure 1 Principal current path when using BCI Two electrically shielded magnetic probes are clamped on one wires or a combination of wires that is/are connected to the device under test. The first probe is for the injection of RF power that induces Idisturbanceonto the wires. The se
47、cond probe is used for monitoring the induced current on those wires. The disturbance current flows in a loop comprising: wire(s), the selected ICs pin(s), Vssterminal, ground path and supportive circuitry. This supportive circuit provides the IC functional elements as source and/or load(s). The sup
48、portive circuitry is directly connected to the IC. When the equivalent RF impedance of the supportive circuitry is larger than 50 , then a by-pass capacitor is recommended. The by-pass capacitor, to be used at the supportive circuitry side, may also be needed to confine the loop area in which the in
49、duced current will be flowing. By default, the lumped by-pass capacitor of 1 nF shall be used. It represents the capacitance from the wire onto a cable harness or chassis. Deviation from using this bypass capacitor (e.g. as functional performance becomes affected) shall be given in the test report The by-pass capacitor may be supplemented with optional decoupling netw