IEC PAS 62815-2-2013 Cold cathode fluorescent lamps – Part 2 Performance specifications (Edition 1.0)《冷阴极荧光灯.第2部分 性能规范》.pdf

上传人:ownview251 文档编号:1237895 上传时间:2019-08-24 格式:PDF 页数:20 大小:2MB
下载 相关 举报
IEC PAS 62815-2-2013 Cold cathode fluorescent lamps – Part 2 Performance specifications (Edition 1.0)《冷阴极荧光灯.第2部分 性能规范》.pdf_第1页
第1页 / 共20页
IEC PAS 62815-2-2013 Cold cathode fluorescent lamps – Part 2 Performance specifications (Edition 1.0)《冷阴极荧光灯.第2部分 性能规范》.pdf_第2页
第2页 / 共20页
IEC PAS 62815-2-2013 Cold cathode fluorescent lamps – Part 2 Performance specifications (Edition 1.0)《冷阴极荧光灯.第2部分 性能规范》.pdf_第3页
第3页 / 共20页
IEC PAS 62815-2-2013 Cold cathode fluorescent lamps – Part 2 Performance specifications (Edition 1.0)《冷阴极荧光灯.第2部分 性能规范》.pdf_第4页
第4页 / 共20页
IEC PAS 62815-2-2013 Cold cathode fluorescent lamps – Part 2 Performance specifications (Edition 1.0)《冷阴极荧光灯.第2部分 性能规范》.pdf_第5页
第5页 / 共20页
点击查看更多>>
资源描述

1、 IEC/PAS 62815-2 Edition 1.0 2013-10 PUBLICLY AVAILABLE SPECIFICATION PRE-STANDARD Cold cathode fluorescent lamps Part 2: Performance specifications IEC/PAS 62815-2:2013(E) THIS PUBLICATION IS COPYRIGHT PROTECTED Copyright 2013 IEC, Geneva, Switzerland All rights reserved. Unless otherwise specified

2、, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or IECs member National Committee in the country of the requester. If you have any questions about IE

3、C copyright or have an enquiry about obtaining additional rights to this publication, please contact the address below or your local IEC member National Committee for further information. IEC Central Office Tel.: +41 22 919 02 11 3, rue de Varemb Fax: +41 22 919 03 00 CH-1211 Geneva 20 infoiec.ch Sw

4、itzerland www.iec.ch About the IEC The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes International Standards for all electrical, electronic and related technologies. About IEC publications The technical content of IEC publications is k

5、ept under constant review by the IEC. Please make sure that you have the latest edition, a corrigenda or an amendment might have been published. Useful links: IEC publications search - www.iec.ch/searchpub The advanced search enables you to find IEC publications by a variety of criteria (reference n

6、umber, text, technical committee,). It also gives information on projects, replaced and withdrawn publications. IEC Just Published - webstore.iec.ch/justpublished Stay up to date on all new IEC publications. Just Published details all new publications released. Available on-line and also once a mont

7、h by email. Electropedia - www.electropedia.org The worlds leading online dictionary of electronic and electrical terms containing more than 30 000 terms and definitions in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical Vocabulary

8、(IEV) on-line. Customer Service Centre - webstore.iec.ch/csc If you wish to give us your feedback on this publication or need further assistance, please contact the Customer Service Centre: csciec.ch. IEC/PAS 62815-2 Edition 1.0 2013-10 PUBLICLY AVAILABLE SPECIFICATION Cold cathode fluorescent lamps

9、 Part 2: Performance specifications INTERNATIONAL ELECTROTECHNICAL COMMISSION P ICS 29.140.99 PRICE CODE ISBN 978-2-8322-1125-0 Registered trademark of the International Electrotechnical Commission Warning! Make sure that you obtained this publication from an authorized distributor. PRE-STANDARD 2 P

10、AS 62815-2 IEC:2013(E) CONTENTS FOREWORD . 3 1 Scope . 5 2 Normative references . 5 3 Terms and definitions . 5 4 Classification 7 5 Lamp requirements . 7 5.1 General . 7 5.2 Tests . 8 5.2.1 General . 8 5.2.2 Construction 8 5.2.3 Starting characteristic 8 5.2.4 Luminance . 8 5.2.5 Luminance uniformi

11、ty. 9 5.2.6 Effective luminance length (under consideration) . 9 5.2.7 Chromaticity coordinates (under consideration) . 9 5.2.8 Colour uniformity . 9 5.2.9 Dark starting time 9 5.2.10 Tube surface temperature 9 5.2.11 Lead wire tensile strength 9 5.2.12 Lead wire bending . 9 5.2.13 Life (Reference).

12、 9 5.3 Marking . 10 Annex A (normative) Dimensions and criteria of CCFL . 12 Annex B (normative) Measurement points of CCFL 13 Annex C (normative) Method of test for CCFL 14 Figure A.1 Dimensions and criteria of CCFL. 12 Figure B.1 Measurement point division method of CCFL 13 Figure C.1 Test circuit

13、 (HOT-GND) 15 Figure C.2 Test circuit (HOT-HOT) . 15 Table 1 Measurement items of test for life and criteria of failure . 10 Table 2 Assurance . 10 Table 3 Inspection levels and the criteria for decision 10 PAS 62815-2 IEC:2013(E) 3 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ COLD CATHODE FLUORESCEN

14、T LAMPS Part 2: Performance specifications FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all

15、questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publica

16、tion(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and non- governmental organizations liaising with the IEC also participate in this preparation. IEC

17、 collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opi

18、nion on the relevant subjects since each technical committee has representation from all interested IEC National Committees. 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to

19、ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any misinterpretation by any end user. 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparentl

20、y to the maximum extent possible in their national and regional publications. Any divergence between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter. 5) IEC itself does not provide any attestation of conformity. Independent certific

21、ation bodies provide conformity assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any services carried out by independent certification bodies. 6) All users should ensure that they have the latest edition of this publication. 7) No liability shall

22、attach to IEC or its directors, employees, servants or agents including individual experts and members of its technical committees and IEC National Committees for any personal injury, property damage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal

23、fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications. 8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is indispensable for the correct application of this public

24、ation. 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights. IEC shall not be held responsible for identifying any or all such patent rights. A PAS is a technical specification not fulfilling the requirements for a standard, b

25、ut made available to the public. IEC/PAS 62815-2 has been processed by subcommittee 34A: Lamps, of IEC technical committee 34: Lamps and related equipment. The text of this PAS is based on the following document: This PAS was approved for publication by the P-members of the committee concerned as in

26、dicated in the following document Draft PAS Report on voting 34A/1596/PAS 34A/1615/RVD Following publication of this PAS, which is a pre-standard publication, the technical committee or subcommittee concerned may transform it into an International Standard. 4 PAS 62815-2 IEC:2013(E) This PAS shall r

27、emain valid for an initial maximum period of 3 years starting from the publication date. The validity may be extended for a single period up to a maximum of 3 years, at the end of which it shall be published as another type of normative document, or shall be withdrawn. PAS 62815-2 IEC:2013(E) 5 COLD

28、 CATHODE FLUORESCENT LAMPS Part 2: Performance specifications 1 Scope This part of IEC/PAS 62815 specifies the performance requirements for tubular type cold cathode fluorescent lamps for backlight unit purposes used to flat panel displays such as TV and monitor etc., hereafter called “lamps”. For o

29、ther types of lamp, additionally it will be revised when a need for them is recognized. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. Fo

30、r undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60050 (all parts), International Electrotechnical Vocabulary (available at ) IEC/PAS 62815-1, Cold cathode fluorecent lamps Safety specifications 3 Terms and definitions For the purposes of th

31、is document, the terms and definitions given in IEC 60050-845 and the following apply. 3.1 cold cathode fluorescent lamp fluorescent lamp with cold cathode, in which most light is emitted by the excitation of phosphors coated in the discharge vessel 3.2 nominal value approximate quantity value used

32、to designate or identify a lamp 3.3 rated value quantity value for a characteristic of a lamp for specified operating conditions Note 1 to entry: The value and the conditions are specified in this PAS, or assigned by the manufacturer or responsible vendor. 3.4 lumen maintenance ratio of the luminous

33、 flux of a lamp at a given time in its life to its initial luminous flux, the lamp being operated under specific conditions Note 1 to entry: The ratio is generally expressed as a percentage. 6 PAS 62815-2 IEC:2013(E) 3.5 initial readings starting characteristics of a lamp, measured before ageing, an

34、d the electrical, photometric and cathode characteristics of a lamp, measured at the end of the 100 h ageing period 3.6 reference inverter special electronic type inverter designed for the purpose of providing comparison standards for use in testing inverters, for the selection of reference lamps an

35、d for testing regular production lamps under standardized conditions, and which, at its rated frequency, has a stable voltage/current ratio which is relatively uninfluenced by variations in current, temperature and magnetic surroundings 3.7 lamp current true r.m.s. type of current across a lamp 3.8

36、lamp voltage true r.m.s. type of voltage across a lamp when measuring the lamp current 3.9 lamp power product of lamp current, lamp voltage and power factor 3.10 power factor ratio of the effective power to the apparent power, (expressed as the effective power divided by the apparent power) 3.11 sta

37、rting voltage voltage between the electrodes required to start the discharge in a lamp 3.12 effective luminance length length of the lamp having a ratio of 80 % from the centre luminance for the distribution of the uniform luminance in a tube-axis direction 3.13 luminance uniformity ratio of maximum

38、 and minimum luminance measured on the horizontally divided points of the lamp, in which the percentage of minimum/maximum luminance among both ends and the centre shall be reported 3.14 luminance stabilization time when centre luminance is regarded as 100 % after starting, time required after switc

39、hing on a lamp to reach 95 % of centre luminance 3.15 light source colour For the light source colour, the definitions of methods of measurement for light source colour apply. a) Coordinates x and y coordinates x and y of a lamp centre PAS 62815-2 IEC:2013(E) 7 b) x and y the difference value betwee

40、n maximum and minimum for each (x, y) coordinates on lamp centre and both ends( and in Figure B.1) 3.16 life length of time during which a complete lamp operates to burn-out or any other end-of-life event described in this PAS 3.17 rated life life stated on the basis of mean value of life for the sa

41、me types of lamp manufactured for a long-term period 3.18 calibration current of a reference ballast value of the current on which the calibration and control of the reference ballast are based 3.19 type test test or a series of tests made on a type test sample for the purpose of checking compliance

42、 of the design of a given product with the requirements of the relevant standard 3.20 type test sample sample consisting of one or more similar units submitted by the manufacturer or responsible vendor for the purpose of a type test 4 Classification According to design specifications, a lamp shall b

43、e classified as follows: a) by function (by application): TV, monitor, communication device, etc. b) by type: lamp diameter & lamp length, lamp shape (straight type), c) by rated current of lamp, d) by chromaticity coordinates of lamp. 5 Lamp requirements 5.1 General A lamp, on which compliance with

44、 this PAS is claimed, shall conform to the safety requirements of cold cathode fluorescent lamps given in IEC/PAS 62815-1. A lamp shall be so designed that its performance is reliable in normal and accepted use. In general, this can be achieved by satisfying the following requirements. The requireme

45、nts and tolerances permitted by this PAS are based on testing of a type test sample submitted by the manufacturer for that purpose. In principle, this type of test sample 8 PAS 62815-2 IEC:2013(E) should consist of units having characteristics typical of the manufacturers production and be as close

46、to the production centre-point values as possible. For guidance on sampling plans and procedures, see IEC 60410. 5.2 Tests 5.2.1 General All tests shall be performed in accordance with Annex C, according to the order arranged by each group in Table 3. In the case of sequential tests with the same sa

47、mple, the former test results shall not influence the following test result, and the destructive test shall be performed last of all. NOTE However, the destructive test can be performed with another sample. 5.2.2 Construction Values of measurement of a lamp diameter, length, and lead wire length sha

48、ll be in accordance with Annex A. The surface of the lamp shall be free from bubbles, flaws and stains that would be an inconvenience during use. 5.2.3 Starting characteristic 5.2.3.1 General starting test Immediately prior to the general starting test, the lamps shall be kept inoperative and in an

49、ambient temperature of between 23 C and 27 C and a relative humidity of 65 % maximum for a period of at least 24 h. When tested as shown in Figure C.1 or C.2 under windless conditions, the lamp shall start within 1 s. 5.2.3.2 Low temperature starting test Immediately prior to the starting test of low temperature the lamps shall be kept inoperative and in an ambient temperature of between 9 C and 11 C and a relative humidity of 65 % maximum for a period of at least 24 h. When tested u

展开阅读全文
相关资源
  • IEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdfIEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdf
  • IEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdfIEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdf
  • IEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdfIEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdf
  • IEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdfIEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdf
  • IEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdfIEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdf
  • IEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdfIEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdf
  • IEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdfIEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdf
  • IEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdfIEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdf
  • IEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdfIEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdf
  • IEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdfIEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > IEC

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1