IEC TR 62456-2007 An electrochemical reference system for use in different solvent media - The decamethylated ferricinium ferrocence redox couple《不同溶剂介质用电化学参考系统.十甲基化二茂铁的氧化还原电对》.pdf

上传人:syndromehi216 文档编号:1238078 上传时间:2019-08-24 格式:PDF 页数:12 大小:255.50KB
下载 相关 举报
IEC TR 62456-2007 An electrochemical reference system for use in different solvent media - The decamethylated ferricinium ferrocence redox couple《不同溶剂介质用电化学参考系统.十甲基化二茂铁的氧化还原电对》.pdf_第1页
第1页 / 共12页
IEC TR 62456-2007 An electrochemical reference system for use in different solvent media - The decamethylated ferricinium ferrocence redox couple《不同溶剂介质用电化学参考系统.十甲基化二茂铁的氧化还原电对》.pdf_第2页
第2页 / 共12页
IEC TR 62456-2007 An electrochemical reference system for use in different solvent media - The decamethylated ferricinium ferrocence redox couple《不同溶剂介质用电化学参考系统.十甲基化二茂铁的氧化还原电对》.pdf_第3页
第3页 / 共12页
IEC TR 62456-2007 An electrochemical reference system for use in different solvent media - The decamethylated ferricinium ferrocence redox couple《不同溶剂介质用电化学参考系统.十甲基化二茂铁的氧化还原电对》.pdf_第4页
第4页 / 共12页
IEC TR 62456-2007 An electrochemical reference system for use in different solvent media - The decamethylated ferricinium ferrocence redox couple《不同溶剂介质用电化学参考系统.十甲基化二茂铁的氧化还原电对》.pdf_第5页
第5页 / 共12页
点击查看更多>>
资源描述

1、 TECHNICAL REPORT IEC TR 62456First edition 2007-03An electrochemical reference system for use in different solvent media The decamethylated ferricinium/ferrocene redox couple Reference number IEC/TR 62456:2007(E) Publication numbering As from 1 January 1997 all IEC publications are issued with a de

2、signation in the 60000 series. For example, IEC 34-1 is now referred to as IEC 60034-1. Consolidated editions The IEC is now publishing consolidated versions of its publications. For example, edition numbers 1.0, 1.1 and 1.2 refer, respectively, to the base publication, the base publication incorpor

3、ating amendment 1 and the base publication incorporating amendments 1 and 2. Further information on IEC publications The technical content of IEC publications is kept under constant review by the IEC, thus ensuring that the content reflects current technology. Information relating to this publicatio

4、n, including its validity, is available in the IEC Catalogue of publications (see below) in addition to new editions, amendments and corrigenda. Information on the subjects under consideration and work in progress undertaken by the technical committee which has prepared this publication, as well as

5、the list of publications issued, is also available from the following: IEC Web Site (www.iec.ch) Catalogue of IEC publications The on-line catalogue on the IEC web site (www.iec.ch/searchpub) enables you to search by a variety of criteria including text searches, technical committees and date of pub

6、lication. On-line information is also available on recently issued publications, withdrawn and replaced publications, as well as corrigenda. IEC Just Published This summary of recently issued publications (www.iec.ch/online_news/ justpub) is also available by email. Please contact the Customer Servi

7、ce Centre (see below) for further information. Customer Service Centre If you have any questions regarding this publication or need further assistance, please contact the Customer Service Centre: Email: custserviec.ch Tel: +41 22 919 02 11 Fax: +41 22 919 03 00 TECHNICAL REPORT IEC TR 62456First edi

8、tion 2007-03An electrochemical reference system for use in different solvent media The decamethylated ferricinium/ferrocene redox couple PRICE CODE IEC 2007 Copyright - all rights reserved No part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical

9、, including photocopying and microfilm, without permission in writing from the publisher. International Electrotechnical Commission, 3, rue de Varemb, PO Box 131, CH-1211 Geneva 20, Switzerland Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmailiec.ch Web: www.iec.ch H For price, se

10、e current catalogue Commission Electrotechnique Internationale International Electrotechnical Commission 2 TR 62456 IEC:2007(E) INTERNATIONAL ELECTROTECHNICAL COMMISSION _ AN ELECTROCHEMICAL REFERENCE SYSTEM FOR USE IN DIFFERENT SOLVENT MEDIA THE DECAMETHYLATED FERRICINIUM/FERROCENE REDOX COUPLE FOR

11、EWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the el

12、ectrical and electronic fields. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to t

13、echnical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and non- governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International O

14、rganization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each techn

15、ical committee has representation from all interested IEC National Committees. 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publi

16、cations is accurate, IEC cannot be held responsible for the way in which they are used or for any misinterpretation by any end user. 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their nati

17、onal and regional publications. Any divergence between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter. 5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any equipment declared to b

18、e in conformity with an IEC Publication. 6) All users should ensure that they have the latest edition of this publication. 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its technical committees and IEC National Committ

19、ees for any personal injury, property damage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications. 8) Attention is drawn to t

20、he Normative references cited in this publication. Use of the referenced publications is indispensable for the correct application of this publication. 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights. IEC shall not be hel

21、d responsible for identifying any or all such patent rights. The main task of IEC technical committees is to prepare International Standards. However, a technical committee may propose the publication of a technical report when it has collected data of a different kind from that which is normally pu

22、blished as an International Standard, for example, “state of the art“. IEC 62456 which is a technical report, has been prepared by subcommittee 65D: Analysing equipment, of IEC technical committee 65: Industrial-process measurement and control. The text of this technical report is based on the follo

23、wing documents: Enquiry draft Report on voting 65D/125/DTR 65D/127/RVC Full information on the voting for the approval of this technical report can be found in the report on voting indicated in the above table. TR 62456 IEC:2007(E) 3 This publication has been drafted in accordance with the ISO/IEC D

24、irectives, Part 2. The committee has decided that the contents of this publication will remain unchanged until the maintenance result date indicated on the IEC web site under “http:/webstore.iec.ch“ in the data related to the specific publication. At this date, the publication will be reconfirmed, w

25、ithdrawn, replaced by a revised edition, or amended. A bilingual version of this publication may be issued at a later date. 4 TR 62456 IEC:2007(E) INTRODUCTION The proposal of this technical report is justified by the difficulties met by electrochemists, electroanalysts, corrosionists, and biologist

26、s when electrode potentials measured in different non-aqueous or aqueous-organic solvents with reference to the familiar, commercially available, and very dependable, aqueous Saturated Calomel Electrode (SCE) are to be physically inter-compared on some “inter-solvental scale” of electrode potentials

27、. These difficulties are caused by the occurrence of two basic extrathermodynamic factors, namely, the primary medium effect 1 1on electrode potentials and the liquid-junction potentials between different solvent media. This report details the use of the half-wave potential of the ferricinium/ferroc

28、ene redox couple or the decamethyl derivatized ferricinium/ferrocene redox couple as the basis of a reference electrode system useful to compared measured electrode potentials to the aqueous saturated calomel electrode when used in various solvent systems. For an acceptable approach to the solution

29、of the above problem, superseding earlier attempts 2, Strehlow and co-workers 3, 4 proposed to use the redox couple ferricinium|ferrocene (in terms of its “half-wave potentials”, or “formal redox potentials”, obtainable from voltametric experiments in different solvents with the same supporting elec

30、trolyte and against the same working reference electrodes), for which, based on an extended experimental evidence, they assessed an “invariancy of potential” to within about 15 mV in a dozen different solvents, assuming the above redox couple to be unaffected by solvent interactions. Principles and

31、reasons for this choice were expounded in detail 3, 4 and need not be repeated here. Strehlows idea was later reassessed in nearly the same terms by Gritzner and K ta 5, but various authors later demonstrated the existence of specific interactions of the ferricinium| ferrocene couple with some of th

32、e solvent media considered, thus partially impairing the intersolvental invariancy of the above redox potentials. However, recently 6, 7, 8, 9, and 10, it was shown that such residual solvent effects could be drastically abated by permethylation of the aromatic rings of the redox couple. For instanc

33、e, the decamethyl- derivatized ferricinium|ferrocene couple, being chemically and electrochemically reversible, with half-wave potentials quite unaffected by the working solvent, lends itself as the best reference-potential redox couple known so far (besides other advantages with respect to the unme

34、thylated parent couple, such as a more general chemical stability, and a more advantageous potential window compared to the operating reference electrode SCE is more advantageously placed). Therefore, what remains to be done by the user is to calibrate the aqueous SCE electrode (which, in common pra

35、ctice, is the reference electrode blindly and invariably used in contact with the non-aqueous solvents studied) versus the half-wave potential of the decamethylferricinium|decamethylferrocene Me 10 Fec + |Me 10 Fec couple in the solvent studied, along the lines explained below, and to apply the cons

36、equent corrections to the measured potentials (see Table 1). The resulting corrected potentials will finally become intersolventally comparable. An additional bonus to the present methodology is provided by the parallel decamethyl- derivatized cobalticinium|cobaltocene Me 10 Coc + |Me 10 Coc redox c

37、ouple because it also was shown to be chemically and electrochemically reversible and its half-wave potential E* differs by a constant value from that of Me 10 Fec + |Me 10 Fec, in terms of E*Me 10 Coc + |Me 10 Coc = E*Me 10 Fec + |Me 10 Fec 1,407 V, at 298,15 K. _ 1Figures in square brackets refer

38、to the Bibliography. TR 62456 IEC:2007(E) 5 AN ELECTROCHEMICAL REFERENCE SYSTEM FOR USE IN DIFFERENT SOLVENT MEDIA THE DECAMETHYLATED FERRICINIUM/FERROCENE REDOX COUPLE 1 Scope The scope of this technical report is to present the background considerations which led to this compilation of potentials

39、of the aqueous saturated calomel electrode compared to the cyclovoltametric data for a glassy carbon electrode in various solvent media. A tabulation of working potentials of this electrode pair in various solvent media is presented. A comparison of the cyclovoltametric scans for the ferricinium/fer

40、rocene and deamethyl derivatized ferricinium/ferrocene redox couple system is presented and important features are discussed. 2 Tabulation of working potentials Clause 2 gives an explanation of the basis for the tabulation of working potentials of the aqueous saturated calomel electrode compared to

41、the ferricinium/ferrocene redox couple and the decamethyl derivatized ferricinium/ferrocene redox couple in various solvent media, as well as an identification of the voltametric range of these couples in various solvent media. 2.1 Working potentials of an SCE Table 1 compiles the working potentials

42、 of the aqueous saturated calomel electrode compared to the ferricinium/ferrocene redox couple and the deamethyl derivatized ferricinium/ferrocne redox couple in various solvent media. Table 1 Working potentials of the aqueous SCE compared to the half-wave potential of the decamethyl derivatized fer

43、ricinium/ferrocene redox couple in various solvent media Solvent E SCE / V aReferences Water 0,144 7 Methanol 0,124 7 Propylene carbonate 0,069 7 Methyl pyrrolidinone 0,055 8 to 10 Acetone 0,021 8 to 10 Acetonitrile 0,119 8 to 10 Methylene chloride 0,060 8 to 10 Dimethyl formamide 0,008 8 to 10 a Va

44、lues to be added to the potentials measured in the solvent studied versus the aqueous SCE to get them referred to the solvent-invariant half-wave potential of the Me 10 Fec + |Me 10 Fec redox couple. NOTE Table 1 gives values for the aqueous SCE at 298K working potential (including insolvental liqui

45、d junction potentials) when compared to the decamethyl derivatized ferricinium/ferrocene redox couple Ferrocene Fec is the dicyclopentadienyl ferrous complex; oxidation to the corresponding ferric complex (ferricinium, Fec + ) is a simple, chemically and electrochemically reversible one- electron pr

46、ocess. The metal ion is buried at the centre of a nearly spherical, big complex; hence, these substances undergo negligible chemical or steric changes when oxidation or reduction occurs. 6 TR 62456 IEC:2007(E) The half-wave potentials of Fec + |Fec were first measured polarographically by Strehlow 3

47、, 4 in concentrated aqueous sulfuric acid solutions with respect to the Hg 2 SO 4electrode in the cell (1): Pt|Fec + |Fec in aq.H 2 SO 4 aq.H 2 SO 4 |Hg 2 SO 4 |Hg|Pt (1) combined with cell (2): Pt|H 2(1 bar)|aq.H 2 SO 4 |Hg 2 SO 4 |Hg|Pt (2) It is readily shown that E 2 E 1= EHg 2 SO 4 EH 2 E*Fec+|

48、Fec + k pH (3) Now, since in Equation (3) the constant term (E Hg2SO4 E H2 E* Fec+|Fec ) is determinable, pH is here a true pH = log(a H+ ) in superacid H 2 SO 4solutions, a quantity not attainable by the conventional IUPAC procedure, which is reliable only in the range 1 pH 13, due to the increasin

49、g effect of residual liquid junction potentials at extreme pH. This interesting scheme can also be applied to other ultra-concentrated acid solutions (HCl, HBr, HI). However, definitely, the most interesting and important opportunity is to use the Fec + |Fec couple in its improved decamethylated form 6, 7, 8, 9, and 10, Me 10 Fec + |Me 10 Fec, as one tool of

展开阅读全文
相关资源
  • IEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdfIEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdf
  • IEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdfIEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdf
  • IEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdfIEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdf
  • IEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdfIEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdf
  • IEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdfIEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdf
  • IEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdfIEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdf
  • IEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdfIEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdf
  • IEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdfIEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdf
  • IEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdfIEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdf
  • IEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdfIEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > IEC

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1