IEC TS 61245-2015 Artificial pollution tests on high-voltage insulators to be used on d.c systems《直流系统用高压绝缘子的人工污秽试验》.pdf

上传人:livefirmly316 文档编号:1238227 上传时间:2019-08-24 格式:PDF 页数:40 大小:2MB
下载 相关 举报
IEC TS 61245-2015 Artificial pollution tests on high-voltage insulators to be used on d.c systems《直流系统用高压绝缘子的人工污秽试验》.pdf_第1页
第1页 / 共40页
IEC TS 61245-2015 Artificial pollution tests on high-voltage insulators to be used on d.c systems《直流系统用高压绝缘子的人工污秽试验》.pdf_第2页
第2页 / 共40页
IEC TS 61245-2015 Artificial pollution tests on high-voltage insulators to be used on d.c systems《直流系统用高压绝缘子的人工污秽试验》.pdf_第3页
第3页 / 共40页
IEC TS 61245-2015 Artificial pollution tests on high-voltage insulators to be used on d.c systems《直流系统用高压绝缘子的人工污秽试验》.pdf_第4页
第4页 / 共40页
IEC TS 61245-2015 Artificial pollution tests on high-voltage insulators to be used on d.c systems《直流系统用高压绝缘子的人工污秽试验》.pdf_第5页
第5页 / 共40页
点击查看更多>>
资源描述

1、 IEC TS 61245 Edition 2.0 2015-03 TECHNICAL SPECIFICATION Artificial pollution tests on high-voltage ceramic and glass insulators to be used on d.c. systems IEC TS 61245:2015-03(en) THIS PUBLICATION IS COPYRIGHT PROTECTED Copyright 2015 IEC, Geneva, Switzerland All rights reserved. Unless otherwise

2、specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or IECs member National Committee in the country of the requester. If you have any questions

3、 about IEC copyright or have an enquiry about obtaining additional rights to this publication, please contact the address below or your local IEC member National Committee for further information. IEC Central Office Tel.: +41 22 919 02 11 3, rue de Varemb Fax: +41 22 919 03 00 CH-1211 Geneva 20 info

4、iec.ch Switzerland www.iec.ch About the IEC The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes International Standards for all electrical, electronic and related technologies. About IEC publications The technical content of IEC publicat

5、ions is kept under constant review by the IEC. Please make sure that you have the latest edition, a corrigenda or an amendment might have been published. IEC Catalogue - webstore.iec.ch/catalogue The stand-alone application for consulting the entire bibliographical information on IEC International S

6、tandards, Technical Specifications, Technical Reports and other documents. Available for PC, Mac OS, Android Tablets and iPad. IEC publications search - www.iec.ch/searchpub The advanced search enables to find IEC publications by a variety of criteria (reference number, text, technical committee,).

7、It also gives information on projects, replaced and withdrawn publications. IEC Just Published - webstore.iec.ch/justpublished Stay up to date on all new IEC publications. Just Published details all new publications released. Available online and also once a month by email. Electropedia - www.electr

8、opedia.org The worlds leading online dictionary of electronic and electrical terms containing more than 30 000 terms and definitions in English and French, with equivalent terms in 15 additional languages. Also known as the International Electrotechnical Vocabulary (IEV) online. IEC Glossary - std.i

9、ec.ch/glossary More than 60 000 electrotechnical terminology entries in English and French extracted from the Terms and Definitions clause of IEC publications issued since 2002. Some entries have been collected from earlier publications of IEC TC 37, 77, 86 and CISPR. IEC Customer Service Centre - w

10、ebstore.iec.ch/csc If you wish to give us your feedback on this publication or need further assistance, please contact the Customer Service Centre: csciec.ch. IEC TS 61245 Edition 2.0 2015-03 TECHNICAL SPECIFICATION Artificial pollution tests on high-voltage ceramic and glass insulators to be used o

11、n d.c. systems INTERNATIONAL ELECTROTECHNICAL COMMISSION ICS 29.080.10 ISBN 978-2-8322-2546-2 Registered trademark of the International Electrotechnical Commission Warning! Make sure that you obtained this publication from an authorized distributor. 2 IEC TS 61245:2015 IEC 2015 CONTENTS FOREWORD . 4

12、 INTRODUCTION . 6 1 Scope 8 2 Normative references. 8 3 Terms and definitions 8 4 General test requirements 11 4.1 General . 11 4.2 Test methods 12 4.3 Arrangement of insulator for test 12 4.3.1 Test configuration 12 4.3.2 Insulator cleaning . 12 4.4 Requirements for the test circuit 13 4.4.1 Test v

13、oltage . 13 4.4.2 Atmospheric corrections . 13 4.4.3 Characteristics of the measuring systems . 13 4.4.4 Identification of flashover . 13 5 Salt fog method . 14 5.1 General information . 14 5.2 Salt solution 14 5.3 Spraying system . 16 5.4 Conditions before starting the test . 19 5.5 Preconditioning

14、 process 19 5.6 Withstand test . 20 5.7 Acceptance criteria for the withstand test . 20 6 Solid layer method . 20 6.1 General information . 20 6.2 Main characteristics of inert materials 21 6.3 Composition of the contaminating suspension 21 6.4 Application of the pollution layer 22 6.5 Determination

15、 of the degree of pollution of the test insulator 23 6.6 Test procedure 23 6.7 Withstand test and acceptance criteria . 24 Annex A (informative) Method for checking the uniformity of the layer . 25 Annex B (informative) Determination of the withstand characteristics of insulators . 27 B.1 General .

16、27 B.2 Determination of the maximum withstand degree of pollution at a given test voltage 27 B.3 Determination of the maximum withstand voltage at a given degree of pollution 27 B.4 Determination of the 50 % withstand voltage at a given degree of pollution . 28 Annex C (informative) Additional recom

17、mendations concerning the solid layer method procedures . 29 C.1 General . 29 C.2 Contamination practice 29 C.3 Drying of the pollution layer . 29 C.4 Checking the wetting action of the fog . 29 IEC TS 61245:2015 IEC 2015 3 C.5 Checking fog uniformity for large or complex test objects . 30 C.6 Fog i

18、nput to the test chamber 30 C.7 Duration of the withstand test 31 C.8 Evaluation of the reference salt deposit density (SDD) 31 Annex D (informative) Information to check equipment for artificial pollution tests . 32 Annex E (informative) Supplementary information on artificial pollution tests on in

19、sulators for voltage systems of 600 kV and above (solid layer method procedure B) 34 E.1 General . 34 E.2 Test chamber 34 E.3 Fog generator . 34 E.4 Wetting action and uniformity of fog density . 34 E.5 Test of very large insulators 34 Annex F (informative) Further investigation 35 Bibliography . 36

20、 Figure 1 Ripple amplitude and actual mean voltage, measured on a resistive load absorbing 100 mA . 9 Figure 2 Voltage drop and voltage overshoot and leakage current . 14 Figure 3 Value of factor b versus solution temperature . 16 Figure 4 Typical construction of fog spray nozzle 18 Figure 5 Test la

21、yout for inclined insulators 19 Figure A.1 Arrangement of the probe electrodes . 25 Figure A.2 Circuit diagram of the meter 26 Figure C.1 Determination of layer conductance and evaluation of its rise time T c= t 2 t 131 Table 1 Salt-fog method: correspondence between the value of salinity and volume

22、 conductivity of the solution at a temperature of 20 C 15 Table 2 Main characteristics of the inert materials used in solid layer suspensions . 21 Table 3 Kaolin (or Tonoko) composition: approximate correspondence between the reference degrees of pollution on the insulator and the volume conductivit

23、y of the suspension at a temperature of 20 C 22 Table D.1 (Provisional) 33 4 IEC TS 61245:2015 IEC 2015 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ ARTIFICIAL POLLUTION TESTS ON HIGH-VOLTAGE CERAMIC AND GLASS INSULATORS TO BE USED ON D.C. SYSTEMS FOREWORD 1) The International Electrotechnical Commis

24、sion (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in

25、 addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee in

26、terested in the subject dealt with may participate in this preparatory work. International, governmental and non- governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in accordanc

27、e with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interes

28、ted IEC National Committees. 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsibl

29、e for the way in which they are used or for any misinterpretation by any end user. 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications. Any divergence bet

30、ween any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter. 5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity assessment services and, in some areas, access to IEC marks of c

31、onformity. IEC is not responsible for any services carried out by independent certification bodies. 6) All users should ensure that they have the latest edition of this publication. 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and m

32、embers of its technical committees and IEC National Committees for any personal injury, property damage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publicatio

33、n or any other IEC Publications. 8) Attention is drawn to the normative references cited in this publication. Use of the referenced publications is indispensable for the correct application of this publication. 9) Attention is drawn to the possibility that some of the elements of this IEC Publicatio

34、n may be the subject of patent rights. IEC shall not be held responsible for identifying any or all such patent rights. The main task of IEC technical committees is to prepare International Standards. In exceptional circumstances, a technical committee may propose the publication of a technical spec

35、ification when the required support cannot be obtained for the publication of an International Standard, despite repeated efforts, or the subject is still under technical development or where, for any other reason, there is the future but no immediate possibility of an agreement on an International

36、Standard. Technical specifications are subject to review within three years of publication to decide whether they can be transformed into International Standards. IEC TS 61245, which is a technical specification, has been prepared by IEC technical committee 36: Insulators. This second edition cancel

37、s and replaces the first edition published in 1993. This edition constitutes a technical revision. IEC TS 61245:2015 IEC 2015 5 This edition includes the following significant technical changes with respect to the previous edition: a) Corrections and the addition of explanatory material; b) The addi

38、tion of Clause 4.4.2 on atmospheric correction; c) The change of upper limit of volume conductivity of tap water for insulator cleaning to 0,1 S/m; d) The extension to UHV voltages; and e) The addition of Annex B “Determination of the withstand characteristics of insulators“ and Annex E “Supplementa

39、ry information on artificial pollution tests on insulators for voltage systems of 600 kV and above (solid layer method procedure B) The text of this technical specification is based on the following documents: Enquiry draft Report on voting 36/352/DTS 36/359/RVC Full information on the voting for th

40、e approval of this technical specification can be found in the report on voting indicated in the above table. This publication has been drafted in accordance with the ISO/IEC Directives, Part 2. The committee has decided that the contents of this publication will remain unchanged until the stability

41、 date indicated on the IEC website under “http:/webstore.iec.ch“ in the data related to the specific publication. At this date, the publication will be transformed into an International standard, reconfirmed, withdrawn, replaced by a revised edition, or amended. A bilingual version of this publicati

42、on may be issued at a later date. 6 IEC TS 61245:2015 IEC 2015 INTRODUCTION The electrical strength of d.c. insulation under pollution conditions determines, in many cases, the dimensions and the design of the insulation. The d.c. test procedures as specified in this technical specification follow c

43、losely the ones established for a.c. by IEC 60507. This does not exclude the possibility that at a later time other d.c. test procedures will be defined. The main differences between this technical specification and IEC 60507 are: test circuit requirements include ripple factor, voltage drop and vol

44、tage overshoot. No requirements are made for the minimum short circuit current or ratio between short circuit and leakage currents; different criteria for the identification of flashover are given; for the salt fog test, a pre-conditioning process with d.c. voltage may be used by agreement; the wett

45、ing rate, rather than the steam injection rate, is prescribed; the measurement of the layer conductance is used to check the wetting action of the fog; as regards the solid layer methods, only the test procedure type “B“ is considered due to the high scatter of the results obtained with tests carrie

46、d out according to the type “A“ procedure. The tests are deemed to be not a suitable measure to prove the insulation performance of polymeric or special types of insulators (e.g. insulators with semiconducting glaze or covered with any organic insulating material) under polluted conditions. The test

47、 procedures given in this standard do not take account of the different properties of insulators such as surface hydrophobicity and hydrophobicity transfer through the pollution layer etc. These questions are under consideration by CIGRE SC D1. For the test methods described in this technical specif

48、ication, it is recommended that the voltage for the withstand voltage tests be specified as the highest value of operating voltage which occurs under normal operating conditions. Other test voltages may be agreed upon. If not otherwise specified and agreed between the parties, voltage of the negativ

49、e polarity will be applied. Only those test methods in which the voltage is held constant during the whole test are considered suitable for standardization. Variants in which the voltage is raised continuously to flashover are not included in this technical specification. The leakage current may be used for interpretation of the test results, and therefore it is recommended that this current be continuously measured during the artificial pollution tests. To achieve repeatable result

展开阅读全文
相关资源
  • IEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdfIEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdf
  • IEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdfIEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdf
  • IEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdfIEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdf
  • IEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdfIEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdf
  • IEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdfIEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdf
  • IEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdfIEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdf
  • IEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdfIEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdf
  • IEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdfIEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdf
  • IEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdfIEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdf
  • IEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdfIEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > IEC

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有