IEC 60335-2-92-2002 Household and similar electrical appliances - Safety - Part 2-92 Particular requirements for pedestrian-controlled mains-operated lawn scari.pdf

上传人:orderah291 文档编号:1241115 上传时间:2019-08-25 格式:PDF 页数:50 大小:1,022KB
下载 相关 举报
IEC 60335-2-92-2002 Household and similar electrical appliances - Safety - Part 2-92 Particular requirements for pedestrian-controlled mains-operated lawn scari.pdf_第1页
第1页 / 共50页
IEC 60335-2-92-2002 Household and similar electrical appliances - Safety - Part 2-92 Particular requirements for pedestrian-controlled mains-operated lawn scari.pdf_第2页
第2页 / 共50页
IEC 60335-2-92-2002 Household and similar electrical appliances - Safety - Part 2-92 Particular requirements for pedestrian-controlled mains-operated lawn scari.pdf_第3页
第3页 / 共50页
IEC 60335-2-92-2002 Household and similar electrical appliances - Safety - Part 2-92 Particular requirements for pedestrian-controlled mains-operated lawn scari.pdf_第4页
第4页 / 共50页
IEC 60335-2-92-2002 Household and similar electrical appliances - Safety - Part 2-92 Particular requirements for pedestrian-controlled mains-operated lawn scari.pdf_第5页
第5页 / 共50页
点击查看更多>>
资源描述

1、INTERNATIONAL STANDARD IEC 60335-2-92 Second edition 2002-07 Household and similar electrical appliances Safety Part 2-92: Particular requirements for pedestrian-controlled mains-operated lawn scarifiers and aerators Appareils lectrodomestiques et analogues Scurit Partie 2-92: Rgles particulires pou

2、r les scarificateurs de gazon et les arateurs fonctionnant sur le rseau et pour conducteur pied Reference number IEC 60335-2-92:2002(E)Publication numbering As from 1 January 1997 all IEC publications are issued with a designation in the 60000 series. For example, IEC 34-1 is now referred to as IEC

3、60034-1. Consolidated editions The IEC is now publishing consolidated versions of its publications. For example, edition numbers 1.0, 1.1 and 1.2 refer, respectively, to the base publication, the base publication incorporating amendment 1 and the base publication incorporating amendments 1 and 2. Fu

4、rther information on IEC publications The technical content of IEC publications is kept under constant review by the IEC, thus ensuring that the content reflects current technology. Information relating to this publication, including its validity, is available in the IEC Catalogue of publications (s

5、ee below) in addition to new editions, amendments and corrigenda. Information on the subjects under consideration and work in progress undertaken by the technical committee which has prepared this publication, as well as the list of publications issued, is also available from the following: IEC Web

6、Site (www.iec.ch) Catalogue of IEC publications The on-line catalogue on the IEC web site (www.iec.ch/catlg-e.htm) enables you to search by a variety of criteria including text searches, technical committees and date of publication. On-line information is also available on recently issued publicatio

7、ns, withdrawn and replaced publications, as well as corrigenda. IEC Just Published This summary of recently issued publications (www.iec.ch/JP.htm) is also available by email. Please contact the Customer Service Centre (see below) for further information. Customer Service Centre If you have any ques

8、tions regarding this publication or need further assistance, please contact the Customer Service Centre: Email: custserviec.ch Tel: +41 22 919 02 11 Fax: +41 22 919 03 00INTERNATIONAL STANDARD IEC 60335-2-92 Second edition 2002-07 Household and similar electrical appliances Safety Part 2-92: Particu

9、lar requirements for pedestrian-controlled mains-operated lawn scarifiers and aerators Appareils lectrodomestiques et analogues Scurit Partie 2-92: Rgles particulires pour les scarificateurs de gazon et les arateurs fonctionnant sur le rseau et pour conducteur pied IEC 2002 Copyright - all rights re

10、served No part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from the publisher. International Electrotechnical Commission, 3, rue de Varemb, PO Box 131, CH-1211 Geneva 20,

11、Switzerland Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmailiec.ch Web: www.iec.ch S For price, see current catalogue PRICE CODE Commission Electrotechnique Internationale International Electrotechnical Commission 2 60335-2-92 IEC:2002(E) CONTENTS FOREWORD 4 INTRODUCTION 6 1 Scop

12、e 7 2 Normative references. 7 3 Definitions . 8 4 General requirement.10 5 General conditions for the tests 10 6 Classification 10 7 Marking and instructions.11 8 Protection against access to live parts13 9 Starting a motor-operated appliance .13 10 Power input and current14 11 Heating.14 12 Void 14

13、 13 Leakage current and electric strength at operating temperature14 14 Transient overvoltages14 15 Moisture resistance.14 16 Leakage current and electric strength .14 17 Overload protection of transformers and associated circuits14 18 Endurance 15 19 Abnormal operation.15 20 Stability and mechanica

14、l hazards15 21 Mechanical strength21 22 Construction .21 23 Internal wiring.23 24 Components .23 25 Supply connection and external flexible cords.23 26 Terminals for external conductors.24 27 Provision for earthing25 28 Screws and connections .25 29 Clearances, creepage distances and solid insulatio

15、n 25 30 Resistance to heat and fire .25 31 Resistance to rusting 25 32 Radiation, toxicity and similar hazards25 Annexes34 Annex AA (normative) Test enclosure construction.34 Annex BB (normative) Base for thrown object test enclosure39 Annex CC (normative) Target panel elevation zones and recommende

16、d test report for thrown object test4260335-2-92 IEC:2002(E) 3 Bibliography44 Figure 101 Safety distances Rotary appliances .26 Figure 102 Safety distances Other lawn scarifiers and aerators.27 Figure 103 Foot probe28 Figure 104 Foot probe test .29 Figure 105 Strength of cutting means.30 Figure 106

17、Operator zone 31 Figure 107 Use of test rod to check guarding of cylinders.32 Figure 108 Side coverage of cylinders32 Figure 109 Guarding of rear discharge cylinders .32 Figure 110 Guarding of front discharge cylinders .32 Figure 111 Impact test fixture for handle insulation 33 Figure AA.1 Thrown ob

18、ject test fixture35 Figure AA.2 Single spindle rotary appliances Test enclosure.36 Figure AA.3 Test enclosure walls and base37 Figure AA.4 Test fixture for corrugated fibreboard penetration test.38 Figure BB.1 Thrown object test fixture base detail40 Figure BB.2 Nail plan of test fixture base .41 Ta

19、ble CC.1 Recommended test data sheet.43 4 60335-2-92 IEC:2002(E) INTERNATIONAL ELECTROTECHNICAL COMMISSION _ HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES SAFETY Part 2-92: Particular requirements for pedestrian-controlled mains-operated lawn scarifiers and aerators FOREWORD 1) The IEC (International

20、Electrotechnical Commission) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of the IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fiel

21、ds. To this end and in addition to other activities, the IEC publishes International Standards. Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and non-govern

22、mental organizations liaising with the IEC also participate in this preparation. The IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of th

23、e IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested National Committees. 3) The documents produced have the form of recommendations for international use and ar

24、e published in the form of standards, technical specifications, technical reports or guides and they are accepted by the National Committees in that sense. 4) In order to promote international unification, IEC National Committees undertake to apply IEC International Standards transparently to the ma

25、ximum extent possible in their national and regional standards. Any divergence between the IEC Standard and the corresponding national or regional standard shall be clearly indicated in the latter. 5) The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible f

26、or any equipment declared to be in conformity with one of its standards. 6) Attention is drawn to the possibility that some of the elements of this International Standard may be the subject of patent rights. The IEC shall not be held responsible for identifying any or all such patent rights. This pa

27、rt of International Standard IEC 60335 has been prepared by IEC subcommittee 61F: Safety of hand-held motor-operated electric tools, of IEC technical committee 61: Safety of household and similar electrical appliances. This second edition cancels and replaces the first edition published in 2000. It

28、constitutes a technical revision. The text of this standard is based on the following documents: FDIS Report on voting 61F/453/FDIS 61F/474/RVD Full information on the voting for the approval of this standard can be found in the report on voting indicated in the above table. This part 2 is to be use

29、d in conjunction with the latest edition of IEC 60335-1 and its amendments. It was established on the basis of the fourth edition (2001) of that standard. NOTE 1 When “Part 1” is mentioned in this standard, it refers to IEC 60335-1. This part 2 supplements or modifies the corresponding clauses in IE

30、C 60335-1, so as to convert that publication into the IEC standard: Safety requirements for pedestrian-controlled mains-operated electric lawn scarifiers and aerators.60335-2-92 IEC:2002(E) 5 When a particular subclause of Part 1 is not mentioned in this part 2, that subclause applies as far as is r

31、easonable. When this standard states “addition”, “modification” or “replacement”, the relevant text in Part 1 is to be adapted accordingly. NOTE 2 The following numbering system is used: subclauses, tables and figures that are numbered starting from 101 are additional to those in Part 1; unless note

32、s are in a new subclause or involve notes in Part 1, they are numbered starting from 101, including those in a replaced clause or subclause; additional annexes are lettered AA, BB, etc. NOTE 3 The following print types are used: requirements proper: in roman type; test specifications: in italic type

33、; notes: in small roman type; Words in bold in the text are defined in Clause 3. When a definition concerns an adjective, the adjective and the associated noun are also in bold. The committee has decided that the contents of this publication will remain unchanged until 2004. At this date, the public

34、ation will be reconfirmed; withdrawn; replaced by a revised edition, or amended. A bilingual version of this publication may be issued at a later date. 6 60335-2-92 IEC:2002(E) INTRODUCTION It has been assumed in the drafting of this international standard that the execution of its provisions is ent

35、rusted to appropriately qualified and experienced persons. This standard recognizes the internationally accepted level of protection against hazards such as electrical, mechanical, thermal, fire and radiation of appliances when operated as in normal use taking into account the manufacturers instruct

36、ions. It also covers abnormal situations that can be expected in practice. This standard takes into account the requirements of IEC 60364 as far as possible so that there is compatibility with the wiring rules when the appliance is connected to the supply mains. However, national wiring rules may di

37、ffer. If an appliance within the scope of this standard also incorporates functions that are covered by another part 2 of IEC 60335, the relevant part 2 is applied to each function separately, as far as is reasonable. If applicable, the influence of one function on the other is taken into account. T

38、his standard is a product family standard dealing with the safety of appliances and takes precedence over horizontal and generic standards covering the same subject. An appliance that complies with the text of this standard will not necessarily be considered to comply with the safety principles of t

39、he standard if, when examined and tested, it is found to have other features that impair the level of safety covered by these requirements. An appliance employing materials or having forms of construction differing from those detailed in the requirements of this standard may be examined and tested a

40、ccording to the intent of the requirements and, if found to be substantially equivalent, may be considered to comply with the standard.60335-2-92 IEC:2002(E) 7 HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES SAFETY Part 2-92: Particular requirements for pedestrian-controlled mains-operated lawn scarifie

41、rs and aerators 1 Scope This clause of Part 1 is replaced by the following. This International Standard deals with the safety of pedestrian-controlled mains-operated electrical lawn scarifiers and aerators with rotating cutters for regenerating lawns by, for instance, combing out grass thatch and mo

42、ss, or by cutting vertically into the lawn face. These scarifiers are designed primarily for use at and around the home or for similar purposes, their rated voltage being not more than 250 V single phase. This standard does not, in general, take into account: the use of appliances by young children

43、or infirm persons without supervision; playing with the appliance by young children. NOTE 101 Attention is drawn to the fact that in many countries additional requirements are specified by the national authorities responsible for the protection of labour. NOTE 102 This standard does not apply to law

44、nmowers (IEC 60335-2-77); lawn trimmers and lawn edge trimmers (IEC 60335-2-91); lawn edgers, flail mowers, sickle-bar mowers or agricultural mowers. 2 Normative references This clause of Part 1 is applicable except as follows. Addition: ISO 2758:2001, Paper Determination of bursting strength ISO 34

45、11:1995, Earth-moving machinery Human physical dimensions of operators and minimum operator space envelope ISO 3767-1:1998, Tractors, machinery for agriculture and forestry, powered lawn and garden equipment Symbols for operator controls and other displays Part 1: Common symbols ISO 3767-3:1995, Tra

46、ctors, machinery for agriculture and forestry, powered lawn and garden equipment Symbols for operator controls and other displays Part 3: Symbols for powered lawn and garden equipment ISO 3864, Safety colours and safety signs ISO 13852:1996, Safety of machinery Safety distances to prevent danger zon

47、es being reached by the upper limbs 8 60335-2-92 IEC:2002(E) 3 Definitions This clause of Part 1 is applicable except as follows. 3.1.9 Replacement: normal operation operation of the appliance under the following conditions: the appliance is operated at rated voltage with the load necessary to attai

48、n rated power input 3.101 braking system a combination of one or more brakes and related means of operation and control 3.102 catcher a part or combination of parts which provides a means for collecting grass, thatch, moss or other debris 3.103 control means or device which will control the operatio

49、n of the appliance or any specific operating function thereof 3.104 cutting means for the purposes of this standard, the mechanism used to provide the cutting action of a scarifier or aerator 3.105 cutting means enclosure (housing) the part of the assembly which provides the protective means around the cutting means 3.106 cutting means tip circle the path d

展开阅读全文
相关资源
  • IEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdfIEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdf
  • IEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdfIEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdf
  • IEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdfIEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdf
  • IEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdfIEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdf
  • IEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdfIEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdf
  • IEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdfIEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdf
  • IEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdfIEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdf
  • IEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdfIEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdf
  • IEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdfIEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdf
  • IEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdfIEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > IEC

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1