ASTM D5096-02(2017) Standard Test Method for Determining the Performance of a Cup Anemometer or Propeller Anemometer.pdf

上传人:周芸 文档编号:360586 上传时间:2019-07-20 格式:PDF 页数:5 大小:124.82KB
下载 相关 举报
ASTM D5096-02(2017) Standard Test Method for Determining the Performance of a Cup Anemometer or Propeller Anemometer.pdf_第1页
第1页 / 共5页
ASTM D5096-02(2017) Standard Test Method for Determining the Performance of a Cup Anemometer or Propeller Anemometer.pdf_第2页
第2页 / 共5页
ASTM D5096-02(2017) Standard Test Method for Determining the Performance of a Cup Anemometer or Propeller Anemometer.pdf_第3页
第3页 / 共5页
ASTM D5096-02(2017) Standard Test Method for Determining the Performance of a Cup Anemometer or Propeller Anemometer.pdf_第4页
第4页 / 共5页
ASTM D5096-02(2017) Standard Test Method for Determining the Performance of a Cup Anemometer or Propeller Anemometer.pdf_第5页
第5页 / 共5页
亲,该文档总共5页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: D5096 02 (Reapproved 2017)Standard Test Method forDetermining the Performance of a Cup Anemometer orPropeller Anemometer1This standard is issued under the fixed designation D5096; the number immediately following the designation indicates the year oforiginal adoption or, in the case of

2、revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the Start-ing Threshold, Distance Constant, Transfe

3、r Function, andOff-Axis Response of a cup anemometer or propeller anemom-eter from direct measurement in a wind tunnel.1.2 This test method provides for a measurement of cupanemometer or propeller anemometer performance in theenvironment of wind tunnel flow. Transference of valuesdetermined by these

4、 methods to atmospheric flow must be donewith an understanding that there is a difference between thetwo flow systems.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-pria

5、te safety and health practices and determine the applica-bility of regulatory limitations prior to use.1.4 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of Internati

6、onal Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D1356 Terminology Relating to Sampling and Analysis ofAtmospheresD3631 Test Methods for Measuring Surface AtmosphericPressure3. Ter

7、minology3.1 For definitions of terms used in this standard, refer toTerminology D1356.3.2 Definitions of Terms Specific to This Standard:3.2.1 starting threshold (Uo, m/s)the lowest wind speed atwhich a rotating anemometer starts and continues to turn andproduce a measurable signal when mounted in i

8、ts normalposition. The normal position for cup anemometers is with theaxis of rotation vertical, and the normal position for propelleranemometers is with the axis of rotation aligned with thedirection of flow. Note that if the anemometer axis is notaligned with the direction of flow, the calculated

9、wind speedcomponent parallel to the anemometer axis is used to deter-mine starting threshold.3.2.2 distance constant (L, m)the distance the air flowspast a rotating anemometer during the time it takes the cupwheel or propeller to reach (1 1e) or 63 % of the equilibriumspeed after a step change in wi

10、nd speed (1).3The response ofa rotating anemometer to a step change in which wind speedincreases instantaneously from U =0toU=Ufis (2):Ut5 Uf1 2 e2t/! (1)where:Ut= is the instantaneous indicated wind speed at time t inm/s,Uf= is the final indicated wind speed, or wind tunnel speed,in m/s,t = is the

11、elapsed time in seconds after the step changeoccurs, and = is the time constant of the instrument.Distance Constant is:L 5 Uf (2)3.2.3 transfer function (f= a + bR, m/s)the linear rela-tionship between wind speed and the rate of rotation of theanemometer throughout the specified working range. fis t

12、hepredicted wind speed in m/s, a is a constant, commonly calledzero offset, in m/s, b is a constant representing the windpassage in m/r for each revolution of the particular anemometercup wheel or propeller, and R is the rate of rotation in r/s. Itshould be noted that zero offset is not the same as

13、startingthreshold. In some very sensitive anemometers the constant a,zero offset, may not be significantly greater than zero. The1This test method is under the jurisdiction of ASTM Committee D22 on AirQuality and is the direct responsibility of Subcommittee D22.11 on Meteorology.Current edition appr

14、oved March 1, 2017. Published March 2017. Originallyapproved in 1990. Last previous edition approved in 2011 as D5096 02 (2011).DOI: 10.1520/D5096-02R17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMSt

15、andards volume information, refer to the standards Document Summary page onthe ASTM website.3The boldface numbers in parentheses refer to the list of references at the end ofthis standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United State

16、sThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trad

17、e (TBT) Committee.1constants a and b must be determined by wind tunnel measure-ment for each type of anemometer (3).3.2.4 off-axis response (U/(Ufcos )the ratio of theindicated wind speed (U ) at various angles of attack ()totheindicated wind speed at zero angle of attack (Uf) multiplied bythe cosin

18、e of the angle of attack. This ratio compares the actualoff-axis response to a cosine response.3.3 Symbols:a (m/s) = zero offset constantb (m/r) = wind passage (apparent pitch) constant orcalibration constantL (m) = distance constantr (none) = a shaft revolutionR (r/s) = rate of rotation(s) = time c

19、onstantt (s) = timeUo(m/s) = starting thresholdU (m/s) = indicated wind speed (used in off-axis test)Uf(m/s) = final indicated wind speed or wind tunnelspeedUmax(m/s) = anemometer application rangeUt(m/s) = instantaneous indicated wind speed at time tf(m/s) = predicted wind speed (deg) = off-axis an

20、gle of attack4. Summary of Test Method4.1 This test method requires a wind tunnel described inSection 6, Apparatus.4.2 Starting Threshold (Uo, m/s) is determined by measur-ing the lowest speed at which a rotating anemometer starts andcontinues to turn and produce a measurable signal whenmounted in i

21、ts normal position.4.3 Distance Constant (L, m) may be determined at anumber of wind speeds but must include 5 m/s, and 10 m/s. Itis computed from the time required for the anemometer rotor toaccelerate (1 1/e) or 63 % of a step change in rotational speedafter release from a restrained, non-rotating

22、 condition. Thefinal response, Uf, is the wind tunnel speed as indicated by theanemometer. In order to avoid the unrealistic effects of therestrained condition, as shown in Fig. 1, the time measurementshould be made from 0.30 of Ufto 0.74 of Uf. This interval inseconds is equal to one time constant

23、() and is converted to theDistance Constant by multiplying by the wind tunnel speed inmeters per second (m/s).4.4 Transfer Function (f= a+bR, m/s) is determined bymeasuring the rate of rotation of the anemometer at a numberof wind speeds throughout the specified working range. In therange of wind sp

24、eeds where the anemometer response isnon-linear (near threshold) a minimum of five data points arerecorded. A minimum of five additional data points arerecorded within the working range of the anemometer andwind tunnel but above the non-linear threshold region (see Fig.2). Measurements are recorded

25、for each data point with thewind tunnel speed ascending and descending. The values of aand b are determined by least-squares linear regression of theindividual data points.4.5 Off-Axis Response may be measured at a number ofwind speeds but must include 5 m/s, and 10 m/s.4.5.1 Cup AnemometersA measur

26、ement is made of theoutput signal when the anemometer is inclined into the wind(representing a down-draft) and away from the wind (repre-senting an updraft), while the wind tunnel is running at a steadyspeed. The output signal is measured with the anemometer axisat 5 intervals from vertical to plus

27、and minus 30 fromvertical. The measured signal is then converted to a ratio foreach interval by dividing by the normal signal measured withthe anemometer axis in the normal, or vertical, position.4.5.2 Vane Mounted Propeller AnemometersA measure-ment is made of the output signal when the anemometers

28、 axisof rotation is inclined downward into the wind (representing adown-draft) and inclined upward into the wind (representing anupdraft), while the wind tunnel is running at a steady speed.The output signal is measured at 5 intervals from a horizontalaxis of rotation to 630 from the horizontal. The

29、 measuredsignal is then converted to a ratio for each interval by dividingby the normal signal with the anemometer in the normal, orhorizontal position. This test may be conducted either with thevane in place or with the vane removed and the axis of rotationfixed in the down-tunnel direction.FIG. 1

30、Typical Anemometer Response CurveFIG. 2 Typical Anemometer Calibration CurveD5096 02 (2017)24.5.3 Fixed Axis Propeller AnemometerA measurement ismade of the output signal when the anemometer is rotated inthe air stream throughout the complete 360 angle of attack.The signal is measured at a number of

31、 angles but must include10 intervals with additional measurements at 85, 95, 265, and275. The measured signal for each angle of attack is thenconverted to a ratio by dividing by the signal measured at 0angle of attack (axial flow). Additionally, the stall angle of thepropeller is measured by orienti

32、ng the anemometer at 90 andslowly rotating into and away from the air flow until thepropeller starts rotating continuously. Stall angle is the totalcontained angle within which the propeller does not continu-ously rotate. The procedure is repeated at 270.5. Significance and Use5.1 This test method w

33、ill provide a standard for comparisonof rotating type anemometers, specifically cup anemometersand propeller anemometers, of different types. Specificationsby regulatory agencies (4-7) and industrial societies havespecified performance values. This standard provides an un-ambiguous method for measur

34、ing Starting Threshold, DistanceConstant, Transfer Function, and Off-Axis Response.6. Apparatus6.1 Measuring System:6.1.1 RotationThe relationship between the rate of rota-tion of the anemometer shaft and the transducer output must bedetermined. The resolution of the anemometer transducerlimits the

35、measurement. The resolution of the measuring orrecording system must represent the indicated wind speed witha resolution of 0.02 m/s.6.1.2 TimeThe resolution of time must be consistent withthe distance accuracy required. For this reason the timeresolution may be changed as the wind tunnel speed isch

36、anged. If one wants a distance constant measurement to 0.1meter resolution one must have a time resolution of 0.05 s at 2m/s and 0.01 s at 10 m/s. If timing accuracy is based on 50 Hzor 60 Hz power frequency it will be at least an order ofmagnitude better than the resolution suggested above.6.1.3 An

37、gle of AttackThe resolution of the angle of attack() must be within 0.5.An ordinary protractor of adequate sizewith 0.5 markings will permit measurements with sufficientresolution. A fixture should be constructed to permit alignmentof the anemometer to the off-axis angles while the wind tunnelis run

38、ning at a steady speed.6.2 Recording Techniques:6.2.1 Digital recording systems and appropriate reductionprograms will be satisfactory if the sampling rate is at least 100samples/s. Exercise care to avoid electronic circuits with timeconstants which limit the proper recording of anemometerperformanc

39、e. Oscilloscopes with memory and hard copy capa-bility may also be used. Another simple technique is to use afast-response strip chart recorder (flat to 10 Hz or better) withenough gain so that the signal produced by the anemometerwhen the wind tunnel is running at 2 m/s is sufficient to providefull

40、 scale pen deflection on the recorder. The recorder chartdrive must have a fast speed of 50 mm/s or more.6.3 Wind Tunnel (8):6.3.1 SizeThe wind tunnel must be large enough so thatthe projection of the cup wheel or propeller, sensor, andsupport apparatus, is less than 5 % of the cross sectional areao

41、f the tunnel test section.6.3.2 Speed RangeThe wind tunnel must have a speedcontrol which will allow the flow rate to be varied from 0 to aminimum of 50 % of the application range of the anemometerunder test. The speed control should maintain the flow ratewithin 60.2 m/s.6.3.3 CalibrationThe mean fl

42、ow rate must be verified atthe mandatory speeds by use of transfer standards which havebeen calibrated at the National Institute of Standards andTechnology or by a fundamental physical method. Speedsbelow 2 m/s for the threshold determination must be verified bya sensitive anemometer or by some fund

43、amental time anddistance technique, such as measuring the transition time ofsmoke puffs, soap bubbles, or heat puffs between two pointsseparated by known distance. A table of wind tunnel blowerrpm or some other index relating method of control to flow rateshould be established by this technique for

44、speeds of 2 m/s andbelow.6.3.4 The wind tunnel must have a relatively constantprofile (known to within 1 %) and a turbulence level of lessthan 1 % throughout the test section.6.3.5 Environment (9-11). Differences of greater than 3 % inthe density of the air within the test environment may result inp

45、oor intercomparability of independent measurements of start-ing threshold (Uo) and distance constant (L) since these valuesare density dependent. The temperature and pressure of theenvironment within the wind tunnel test section, and theambient air pressure (Test Methods D3631) shall be reportedfor

46、each independent measurement.7. Sampling7.1 Starting ThresholdThe arithmetic mean on ten con-secutive tests is required for a valid starting threshold mea-surement.7.2 Distance ConstantThe arithmetic mean of ten tests isrequired for a valid measurement at each speed. The results ofthe measurements a

47、t two or more speeds are averaged to asingle value for distance constant.7.3 Transfer FunctionTwo measurements of Ufand R arerecorded for each data point, one with the wind tunnel speedascending and one with the wind tunnel speed descending. Thevalues are then tabulated for each data point.7.4 Off-A

48、xis ResponseThe results of the measurement attwo or more speeds are averaged to a single value for eachangle of attack. The averaged values are tabulated for eachangle of attack.8. Procedure8.1 Starting Threshold (Uo):8.1.1 Provide a mechanical method for holding the an-emometer in its normal positi

49、on (see 3.1) and for releasing theanemometer from a restrained, or non-rotating condition, whilethe wind tunnel is running at the test speed. Test the releaseD5096 02 (2017)3mechanism with the wind tunnel off to verify that the releasemethod does not move the anemometer rotor when activated.8.1.2 Set the wind tunnel to a speed that is lower than thestarting threshold. Slowly increase the wind tunnel speed untilthe cup wheel or propeller continues to rotate and produce ameasurable signal.8.1.3 Repeat the procedure of 8.1.2 ten tim