1、AECMA STANDARD NORME AECMA AECMA NORM Edition approved for publication 28 February 2003 prEN 41 65-01 2 Edition P 1 February 2003 Comments should be sent within six months after the date of publication to Electrical Domain AECMA-STAN ICs: 49.060 Descriptors: ENGLISH VERSION Aerospace series Connecto
2、rs, electrical, rectangular, modular Operating temperature 175 OC continuous Part 012: Flange mounting receptacle 2 and 4 modules, series 3 Product standard Srie arospatiale Luft- und Raumfahrt Connecteurs lectriques rectangulaires Elektrischer Rechtecksteckverbinder Temprature dutilisation 175 OC c
3、ontinu Betriebstemperatur 175 OC konstant Partie 012 : Embase collerette Teil 012: Feste Steckverbinder mit Montageflansch 2 et 4 modules, srie 3 mit 2 und 4 Modulen, Serie 3 modulaires in modularer Bauweise Norme de produit Produktnorm This “Aerospace Series“ Prestandard has been drawn up under the
4、 responsibility of AECMA-STAN (The European Association of Aerospace Industries - Standardization). It is published on green paper for the needs of the European Aerospace Industry. It has been technically approved by the experts of the concerned Domain following member comments. Subsequent to the pu
5、blication of this Prestandard, the technical content shall not be changed to an extent that interchangeability is affected, physically or functionally, without re-identification of the standard. After examination and review by users and formal agreement of AECMA-STAN it will be submitted as a draft
6、European Standard to CEN (European Committee for Standardization) for formal vote. Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Page 2 prEN 4165-012
7、: 2003 Foreword This standard was reviewed by the Domain Technical Coordinator of AECMA-STANS Electrical Domain. After inquiries and votes carried out in accordance with the rules of AECMA-STAN defined in AECMA- STANS General Process Manual, this standard has received approval for Publication. Conte
8、nts Page 1 Scope 2 Normative references . 3 Terminology 4 Required characteristics 5 Flange mounting receptacle . 6 Designation . 7 Marking . 8 Technical specification Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo r
9、eproduction or networking permitted without license from IHS-,-,-Page 3 prEN 41 65-01 2: 2003 1 Scope This standard defines the flange mounting receptacle 2 or 4 modules, series 3 used in the family of rectangular electrical connectors. The plugs corresponding to those receptacles are defined in EN
10、41 65-002. The protective covers corresponding to those receptacles are defined in EN 41 65-01 8. 2 Normative references This European Standard incorporates by dated or undated reference provisions from other publications. These normative references are cited at the appropriate places in the text an
11、d the publications are listed hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to this European Standard only when incorporated in it by amendment or revision. For undated references the latest edition of the publication referred to apply. EN
12、2424, EN 41 65-001, EN 41 65-002, EN 41 65-01 8, Aerospace series - Marking of aerospace products Aerospace series - Connectors, electrical, rectangular, modular - Operating temperature I75 “C continuous - Part 001: Technical specification - Product standard 1 ) Aerospace series - Connectors, electr
13、ical, rectangular, modular - Operating temperature I75 “C continuous - Part 002: Specification of performance and contact arrangements 1) Aerospace series - Connectors, electrical, rectangular, modular - Operating temperature 175 “C continuous - Part 018: Protective cover for receptacle, 2 and 4 mod
14、ules, series 2 and series 3 - Product standard 1 ) EN 41 65-020, Aerospace series - Connectors, electrical, rectangular, modular - Operating temperature 175 “C continuous - Part 020: Coupling system keyway for receptacle - Product standard 1) 3 Term in ol ogy See EN 4165-001. 4 Required characterist
15、ics Dimensions are in millimetres. 1) Published as AECMA standard at the date of publication of this standard Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from I
16、HS-,-,-Page 4 prEN 4165-012: 2003 5 Flange mounting receptacle 5.1 See Figure 1. For 2 modules classes W, F and A Key 1 2 accepted form of flange groove only for class W, F and A Figure 1 Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AEC
17、MANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Page 5 prEN 41 65-01 2: 2003 5.2 See Figure 2. For 4 modules classes W, F and A Key 1 groove only for class W, F and A 2 accepted form of flange Figure 2 Copyright Association Europeene des Constructeurs de Materiel
18、 Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Page 6 prEN 4165-012: 2003 Table 1 - Flange mounting receptacles class Class W F A Description Flange mounting receptacles with housing (shell) olive drab cadmium p
19、lated, aluminium alloy, conducting finish, 500 hours resistance to salt mist, maximum operating temperature 175 “C continuous Flange mounting receptacles with housing (shell) black nickel plated, aluminium alloy, 96 hours resistance to salt mist, maximum operating temperature 175 “C continuous Flang
20、e mounting receptacles with housing (shell) black anodised plated, aluminium alloy, no conducting finish, 48 hours resistance to salt mist, maximum operating temperature 175 “C continuous 6 Designation EXAMPLE: Description block Identity block ELECTRICAL CONNECTOR PLUG EN41 65F7B4 Number of the basi
21、c standard Class type (see Table 1) Type 7: Receptacle (see EN 4165-002) B = series 3 Shell type 4 = plug 4 modules 2 = plug 2 modules Plug keying coupling (number not marked on the connector) O - Not delivered A = Standard Keying code (special coding) 4 5 6 State of delivery receptacle keying coupl
22、ing (see EN 41 65-020) (Not marked on the connector) O - Delivered: not fitted Fitted in the receptacle 4 5 6 Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from I
23、HS-,-,-Page 7 prEN 4165-01 2: 2003 7 Marking Unless there are other specific contractual requirements, the marking shall be in accordance with EN 2424, category P. 8 Technical specification See EN 4165-001. Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-