1、 . A-A-59578 10 June 2004 COMMERCIAL ITEM DESCRIPTION GENERATOR, FUNCTION (0.1 Hz to 4 MHz) The General Services Administration has authorized the use of this commercial item description, for all federal agencies. 1. SCOPE. This Commercial Item Description (CID) describes the minimum requirements fo

2、r a Function Generator. The equipment, as described in this CID, shall have a minimum frequency range of 0.1 Hz to 4 MHz. This CID is meant as a minimum requirement for the function generator in which only those manufacturers that meet or surpass the following requirements are to supply this generat

3、or per this CID. 2. SALIENT CHARACTERISTICS. The equipment shall be capable of operation within the accuracies, limits, and specifications herein. 2.1 Classification. Equipment covered by this CID shall be commercially available equipment and may be modified to the extent necessary to meet the follo

4、wing description. The equipment shall be Class 3, in accordance with MIL-PRF-28800, except as specified herein. 2.2 Safety and Environmental. The equipment shall meet all safety and environmental requirements as specified in MIL-PRF-28800 for the classification as stated herein except as specified h

5、erein. 2.2.1 Temperature Operating. The equipment shall conform to its specified performance and accuracy while being operated in a temperature range of 0C to +50C. 2.2.2 Temperature Non-operating. The equipment shall conform to its specified performance and accuracy after being stored in an environ

6、ment in the temperature range of -20C to +70C. AMSC N/A FSC 6625 INCH-POUNDBeneficial comments, recommendations, additions, deletions, clarifications, etc. and any data that may improve this document should be sent to: WR-ALC/LEEC, 295 Byron Street, Robins AFB, GA 31098-1611 Provided by IHSNot for R

7、esaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59578 22.3 Electrical Power Sources. The equipment shall operate from nominal commercial, military, and shipboard power sources of 120 VAC (10 %) at line frequencies of 48 Hz to 63 Hz and 240 VAC (10 %) at line frequencies

8、 of 48 Hz to 63 Hz. Transient state conditions shall meet MIL-PRF-28800 requirements for the classification specified herein. 2.4 Reliability. The design of the equipment shall be such that under normal use and operation the equipment does not fail within 4000 hours of operation with a statistical c

9、ertainty of 95%. 2.5 Calibration and Maintenance Adjustments. The design of the system shall provide for readily accessible calibration adjustments and maintenance adjustments. The calibration adjustments, wherever possible, shall be accessible without removal of the equipment case or modules. The c

10、alibration interval shall be a period of one year or greater based on an operating time of 2000 hours. No special tools shall be required for alignment or adjustment except those furnished with the equipment. 2.6 Performance Requirements. The equipment shall meet all requirements specified herein, a

11、fter the warm-up period specified in MIL-PRF-28800, under all combinations of input power conditions, output signal conditions and operating service condition as specified in MIL-PRF-28800. 2.6.1 Frequency Range. The frequency range shall be at least 0.1 Hz to 4 MHz. 2.6.1.2 Accuracy. The frequency

12、accuracy shall be at least 5 % of full scale. 2.6.2 Waveforms. The function generator shall have as a minimum a sine wave, triangle wave, square wave and pulse output. 2.6.2.1 Sine Wave Distortion. The sine wave distortion shall not be greater than 1% to 1 MHz. From 1 MHz to 4 MHz the distortion sha

13、ll be at least 25 dB below the fundamental. 2.6.2.2 Triangle Linearity. The triangle linearity shall be at least 95% or better to 200 kHz. 2.6.2.3 Square wave and Pulse Rise and Fall Time. The square wave and pulse rise and fall time shall be less than 50ns for 10 Vpp into a 50 ohm load. 2.6.3 Opera

14、tional Modes. The function generator shall have at a minimum the following selectable modes: 2.6.3.1 Triggered Mode. Manual or external trigger initiates one complete waveform. The trigger shall be at least meet the following characteristics: Impedance: 10 k? 5% Maximum Input Voltage: TTL compatible

15、 Minimum Pulse Width: 100 ns Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59578 32.6.3.2 Gated Mode. Manual or external trigger initiates a continuous wavetrain while the trigger signal is applied. The gated mode trigger shall at least be the

16、same as the triggered mode characteristics. 2.6.3.3 Continuous Mode. Generator provides an uninterrupted wave train at the selected frequency. 2.6.4 Sweep Mode. The function generator shall have a linear and a logarithmic sweep mode. The sweep shall include a selectable sweep range of 1:1000 in the

17、linear mode and 1:100000 in the logarithmic mode. 2.7 Physical Characteristics. The function generators component dimensions and weight shall be consistent with current commercial offerings. The equipment shall have the following physical characteristics. 2.7.1 Dimensions. The width and depth of the

18、 equipment shall be compatible with mounting in an ANSI/EIA-310-D standard equipment rack. The height shall be compatible with four standard height units, 4U. One unit or “U“ is defined by ANSI/EIA-310 to be 1.75 inches or 44.45 mm. 2.7.2 Weight. The total weight of the equipment, excluding accessor

19、ies and manuals, shall not exceed that of a one-man lift, 37 lbs (or 16.78 kg). If the depth of the equipment is greater than 24 inches the maximum allowable weight shall be reduced by 33 percent. 2.7.3 Rackmount. Rackmount capability shall be available as an option for the equipment specified herei

20、n. 2.7.4 Signal Input and Output Connectors. Unless otherwise specified, all signal input and output connectors shall be Type BNC female. 2.7.5 Manuals. The equipment shall be delivered with operator, maintenance, illustrated parts, and calibration manuals. Format and quantity shall be as specified

21、in the contract or order. Level of maintenance philosophy, as defined in MIL-PRF-28800, shall be as specified in the contract or order. 3. REGULATORY REQUIREMENTS. 3.1 The offeror/contractor is encouraged to use recovered materials to the maximum extent practicable, in accordance with paragraph 23.4

22、03 of the Federal Acquisition Regulation (FAR). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59578 44. PRODUCT CONFORMANCE. 4.1 Product Conformance. The products provided shall meet the salient characteristics of this CID, conform to the produ

23、cers own drawings, specifications, standards and quality assurance practices, and be the same product offered for sale in the commercial market. The government reserves the right to require proof of such conformance. 4.2 Metric Products. Products manufactured to metric dimensions will be considered

24、on an equal basis with those manufactured using inch-pound units, provided they fall within the specified tolerances using conversion tables contained in the latest revision of Federal Standard No. 376, and all other requirements of this CID are met. If a product manufactured to metric dimensions ex

25、ceeds the tolerances specified in the inch/pound units, a request should be made to the contracting officer to determine if the product is acceptable. 4.3 The contracting officer has the option of accepting or rejecting the product. 5. PACKAGING. Preservation, packing, and marking shall be as specif

26、ied in the contract or order. 6. NOTES. 6.1 Sources of documents. 6.1.1 Military Specifications, Standards, and Handbooks referenced herein may be obtained from the Standardization Documents Order Desk, 700 Robbins Ave, Bldg 4, Section D, Philadelphia, PA 19111-5094. 6.1.2 The Code of Federal Regula

27、tions (CFR) may be obtained from the Superintendent of Documents, U.S. Government Printing Office, Washington, DC, 20402. 6.1.3 ANSI/EIA standards may be obtained from the Electronics Industry Association, Engineering Department, 2001 Pennsylvania Ave., N.W., Washington, D.C., 20006. Phone: 1-800-85

28、4-7179 (USA and Canada). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59578 5MILITARY INTEREST Custodian: Preparing activity: Air Force 99 Air Force - 84 Agent: Air Force - 99 (Project 6625-F091) NOTE: The activities listed above were interest

29、ed in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at www.dodssp.daps.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-