1、m 0b L377Lb 327 m CANCELED Y MIL-G- 71 70A AMENDMENT 2 24 APRIL 1981 Sup ers e ding AMENDMEYT 1 20 MARCH 1973 MILITARY SPECIFICATION GAGE, PRESSUrlX, MANIFOLD, DIRECT INDICATING 2 INCII SIZE, 10-75 INCHES MERCURY This amendment forms a part of Military Specification MIL-G-7170A, dated 12 May 1965, a

2、nd is approved for use by all Departments and Agencies of the Department of Defense. PAGE 1 2.1: Under SPECIFICATIONS, Military, delete the following: “MIL-P-6906 and MIL-P-7936“. 2.1: Under SPECIFICATIONS, Military, add the following: “DoD-D- 1000 Drawings, Engineering And Associated Lists“ Add the

3、 following boxed paragraph to bottom of page: “Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: HQ AFLC CASO/LODS, Federal Center, Battle Creek MI 49016 by using the self-addressed Standardizatio

4、n Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by letter.“ 2.1: Under SPECIFICATIONS, Military, delete “MIL-D-70327“. 2.1: Under STANDARDS, Military, add the following: “MIL- STD- 794 MIL-STD-889 Parts And Equipment, Procedures For Packaging And Packing Of Di

5、ssimilar Metals“ 2.1: Under STANDARDS , Military, delete “MS33586“. tus. GOVERNMENT PRINTING omcE: isei-703-0231272 FSC 6620 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-G-7170A AMENDMENT 2 PAGE 3 3.1: Delete and substitute the following: “3.1

6、 First article. This specification makes provisions for first article testing.“ 3.3.2. I: 889“. Delete reference to MS33586“ .and substitute “MIL-STD- PAGE 5 3.8: 100 O“. Delete reference to “MIL-D-70327“ and substitute “DoD-D- PAGE 7 4.2, 4.3 and 4.3.1: substitut e “first art ic le“ . Delete refere

7、nce to “qualification“ and PAq4 13 Add paragraph 4.8 as follows: “4.8 and packaging shall be accomplished in accordance with Section 4 of MIL-P-116 to insure compliance with Section 5 of this specification. 5.: Delete 5 through 5.3 and substitute: Inspection and test. Tests of methods of preservatio

8、n Il “5. PACKAGING 5.1 Preservation-packaging. Preservation-packaging shall be Level A or C as specitied. 5.1.1 Level A. 5.1.1.1 Cleaning. Gages shall be cleaned in accordance with Process C-1 of MIL-P-116. 5.1.1.2 D- in Gages shall be dried in accordance with Process D-4 of MIL- -6. Page 2 of 4 Pro

9、vided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-9999906 1937718 LTT U . MIL-G-7170A AMENDMENT 2 5.1.1.3 Preservation application. Not applicable. 5.1 Pro uni .1.4 Unit packaging. Unless otherwise specified by the curing activity, each gage shall be pack

10、aged in quantity t Dacks of one each in accordance with Method IC-1 of r -_ - MIL-P-116. Overbox completed pack in PPP-B-636 container. Apply sufficient cushioning material between bag and unit container of a type, density and thickness to insure shock transmission does not exceed peak values in Gs

11、established for the gage, when completed packs are subjected to the rough handling drop tests of MIL-P-116. 5.1.2 Level C. Same as Level A except Method III of MIL-P-116 applies in lieu of Method IC-1. 5.2 Packing. Packing shall be Level A, B or C as specified by the procuring activity. 5.2.1 Level

12、A. Gages packaged as specified in 5.1.1 shall be packed -ping containers conforming to PPP-B-636, weather- resistant class, unless otherwise specified by the procuring activity. Insofar as practical, exterior shipping containers shall be of uniform shape, size, minimum tare and cube consis- tent wit

13、h the protection required. applies for Army use. 5.2.2 Level B. packed instic class exterior shipping containers conforming to PPP-B-636. Other requirements as specified in 5.2.1 above shall apply. 5.2.3 Level C. Packing shall be applied which affords adequate protection during domestic shipment fro

14、m the supply source to the first receiving activity for immediate use. level shall conformto applicable carrier rules and regulations and may be the contractors commercial practice, provided the latter meets the requirements of this level. Table II of MIL-STD-794 Gages packaged as specified in 5.1.1

15、 shall be This 5.3 Marking for shipment and storage. Interior and exterior containers shall b e marked in accordance with MIL-STD-129.“ PAGE 14 6.3: Delete and substitute the following: “Selection of applicable levels of packaging (see 5) .“ 1 Page 3 of 4 Provided by IHSNot for ResaleNo reproduction

16、 or networking permitted without license from IHS-,-,- 9999906 1937719 O36 MIL-G-717OA AMENDMENT 2 6.4: Delete and substitute: “6.4 Reclaimed materials. The use of reclaimed materials shall be encouraged to the maximum extent possible without jeopardizing the intended end use of the item.“ 6.5: Delete in its entirety. Custodian: Air Force - 99 Army - AV Navy - AS Preparing Activity: Air Force - 99 Project Number: 6620-0319 Page 4 of 4 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-