资源描述

1、Performance of Full-bore Vortex Meters for Measurement of Liquid FlowsAPI TECHNICAL REPORT 2577 FIRST EDITION, JULY 2018Special NotesAPI publications necessarily address problems of a general nature. With respect to particular circumstances, local, state, and federal laws and regulations should be r

2、eviewed.Neither API nor any of APIs employees, subcontractors, consultants, committees, or other assignees make any warranty or representation, either express or implied, with respect to the accuracy, completeness, or usefulness of the information contained herein, or assume any liability or respons

3、ibility for any use, or the results of such use, of any information or process disclosed in this publication. Neither API nor any of APIs employees, subcontractors, consultants, or other assignees represent that use of this publication would not infringe upon privately owned rights.API publications

4、may be used by anyone desiring to do so. Every effort has been made by the Institute to ensure the accuracy and reliability of the data contained in them; however, the Institute makes no representation, warranty, or guarantee in connection with this publication and hereby expressly disclaims any lia

5、bility or responsibility for loss or damage resulting from its use or for the violation of any authorities having jurisdiction with which this publication may conflict.API publications are published to facilitate the broad availability of proven, sound engineering and operating practices. These publ

6、ications are not intended to obviate the need for applying sound engineering judgment regarding when and where these publications should be utilized. The formulation and publication of API publications is not intended in any way to inhibit anyone from using any other practices.Any manufacturer marki

7、ng equipment or materials in conformance with the marking requirements of an API standard is solely responsible for complying with all the applicable requirements of that standard. API does not represent, warrant, or guarantee that such products do in fact conform to the applicable API standard.All

8、rights reserved. No part of this work may be reproduced, translated, stored in a retrieval system, or transmitted by any means, electronic, mechanical, photocopying, recording, or otherwise, without prior written permission from the publisher. Contact the Publisher, API Publishing Services, 1220 L S

9、treet, NW, Washington, DC 20005.Copyright 2018 American Petroleum InstituteForewordNothing contained in any API publication is to be construed as granting any right, by implication or otherwise, for the manufacture, sale, or use of any method, apparatus, or product covered by letters patent. Neither

10、 should anything contained in the publication be construed as insuring anyone against liability for infringement of letters patent.The verbal forms used to express the provisions in this specification are as follows: the term “shall” denotes a minimum requirement in order to conform to the standard;

11、 the term “should” denotes a recommendation or that which is advised but not required in order to conform to the standard; the term “may” is used to express permission or a provision that is optional; the term “can” is used to express possibility or capability.Informative elementsAs used in a standa

12、rd, “informative” denotes elements that identify the document, introduce its content, and explain its background, development, and its relationship with other documents or provide additional information intended to assist the understanding or use of the document.Normative elementsAs used in a standa

13、rd, “normative” denotes elements that describe the scope of the document and that set out provisions that are required to implement the standard.This document was produced under API standardization procedures that ensure appropriate notification and participation in the developmental process and is

14、designated as an API standard. Questions concerning the interpretation of the content of this publication or comments and questions concerning the procedures under which this publication was developed should be directed in writing to the Director of Standards, American Petroleum Institute, 1220 L St

15、reet, NW, Washington, DC 20005. Requests for permission to reproduce or translate all or any part of the material published herein should also be addressed to the director.Generally, API standards are reviewed and revised, reaffirmed, or withdrawn at least every five years. A one-time extension of u

16、p to two years may be added to this review cycle. Status of the publication can be ascertained from the API Standards Department, telephone (202) 682-8000. A catalog of API publications and materials is published annually by API, 1220 L Street, NW, Washington, DC 20005.Suggested revisions are invite

17、d and should be submitted to the Standards Department, API, 1220 L Street, NW, Washington, DC 20005, standardsapi.org.iiiContentsPage1 Scope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

18、 . . 12 References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Terms, Definitions, and Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

19、. . . . . . . . . . . . . 13.11 Abbreviations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Field of Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

20、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Test Matrix for Full-bore Vortex Meter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25.1 Baseline Calibration at the Calibration Facility . . . . . . . . . . . . . . .

21、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35.2 Field Testing of Vortex Meter with Hydrocarbon Fluids . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Test Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

22、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56.1 4-in. (100-mm) Vortex Meter Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 4-in. (100-mm) Vortex Meter Performance in the Field with Hydrocarbon F

23、luids . . . . . . . . . . . . . . . . . . . . 88 2-in. (50-mm) Vortex Meter Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149 Additional Test Results from Other Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

24、 . . . . . . . . . . . . . . . . . 1710 Conclusion. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Annex A (informative) Plots of Baseline Proving Data of 4-in. (100-mm) Vortex Meters . . . . .

25、 . . . . . . . . . . . . 18Annex B (informative) Experimental Data from OIML D 25 Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Figures1 Schematic Setup at the Calibration Facility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

26、. . . . . . . 32 Calibration Facility Test Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Portable Proving Operation in the Field . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

27、. . . . . . . . . . 44 Typical Shape of a Meter Factor Curve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 Composite Plot of Meter Factors (MF) of Five Vortex Meters for Master Meter Proves . . . . . . . . . . . . . . . 76 Composite Pl

28、ot of Vortex Meter Repeatability for Master Meter Proves . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 Composite Plot of Difference in Meter Factor for Five Vortex Meter Data Calibrated by Master Meter and Small Volume Prover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

29、 . . . . . . . . . . . . . . . . . . . . . . 88 Performance of Meter A and Meter D (Meter Factor vs Flow Rate) for Hydrocarbon Flows . . . . . . . . . . 119 Performance of Meter A and Meter D (Meter Factor vs API Gravity Hydrocarbon Fluid) . . . . . . . . . . . . . 1110 Performance of Meter D (Meter

30、 Factor vs Flow Rate) for Hydrocarbon Fluids . . . . . . . . . . . . . . . . . . . . . 1211 Performance of Meter D (Meter Factor vs Degree API of Hydrocarbon Fluids) . . . . . . . . . . . . . . . . . . . . 1212 Meter A Performance at Different Flow Rates . . . . . . . . . . . . . . . . . . . . . . .

31、 . . . . . . . . . . . . . . . . . . . . . . . . . 1313 Performance of Meter A (Meter Factor vs Degree API of Hydrocarbon Fluids) . . . . . . . . . . . . . . . . . . . . 1314 Performance of Meter E (Meter Factor vs Flow Rate) for Hydrocarbon Fluids . . . . . . . . . . . . . . . . . . . . . 1415 Perf

32、ormance of Meter E (Repeatability on Points vs Degree API of the Hydrocarbon Fluid) . . . . . . . . . 1416 Meter Factor vs Flow Rate for 2-in. (50-mm) Meter F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1517 Meter Factor vs Flow Rate for 2-in. (50-mm) Meter G

33、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1518 Meter Factor vs Flow Rate for 2-in. (50-mm) Meter H . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1619 Composite Calibration Data of 2-in. (50-mm) Meter F, Meter G, and Mete

34、r H Calibrated by Small Volume Prover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16A.1 Meter Factor of Vortex Meter A by SVP and Turbine as the Master Meter . . . . . . . . . . . . . . . . . . . . . . . . . 18A.

35、2 Meter Factor of Vortex Meter-B by SVP and Turbine as the Master Meter . . . . . . . . . . . . . . . . . . . . . . . . . 18A.3 Meter Factor vs Flow rate of Vortex Meter C by SVP and Turbine as the Master Meter . . . . . . . . . . . . . . 19A.4 Meter Factor of Vortex Meter D by SVP and Turbine as th

36、e Master Meter . . . . . . . . . . . . . . . . . . . . . . . . . 19vContentsPageA.5 Meter Factor of Vortex Meter E by SVP and Turbine as the Master Meter . . . . . . . . . . . . . . . . . . . . . . . . . 20B.1 Relation between Strouhal Number and Reynolds Number for a Vortex Meter . . . . . . . . .

37、. . . . . . . . . . . 21B.2 Meter Accuracy vs Reynolds Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Tables1 Summary Data of all Master Meter Proves at the Calibration Facility . . . . . . . . . . . . . . . . . . . . . . . . . .

38、. . . 62 Summary Data of Meter A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 Summary Data of Meter B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

39、. . . . . . . . . . 94 Summary Data of Meter C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95 Summary Data of Meter D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

40、. . . . . . . . . . . . . . . . 106 Summary Data of Meter E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10viIntroduction This technical report documents performance characteristics of several commercially available v

41、ortex meters for liquid flows. Although vortex meters are available in full-bore and reduced-bore designs, performance verification and characterization were limited to full-bore liquid vortex meters only, due to the inadequacy of test data available in the public domain for reduced-bored designs an

42、d lack of funding to develop a field test database for hydrocarbon liquids. Vortex meter test results reported in this document are of nominal 2-in. (50-mm) and 4-in. (100-mm) meter sizes. Five vortex meter vendors participated in the laboratory and field tests with hydrocarbon liquid of 4-in. (100-

43、mm) meters, while only three manufacturers participated in the 2-in. (50-mm) tests. Since the flow rate through 2-in. (50-mm) vortex meters is relatively low, its use in field trials with hydrocarbon fluids was not possible, as it would delay and limit the normal operation of the field meter. Theref

44、ore, 2-in. (50-mm) vortex meter tests were limited to performance verification at the laboratory test facility with water only.The baseline performance of each meter was established under controlled flowing conditions of the laboratory test facility, where the test fluid was water. Commercially avai

45、lable 4-in. (100-mm) vortex meters output may have a manufactured pulse, where the pulse output is used during proving of the meter to establish the meter factor and repeatability of the meter factor. Also, due to time variations of shed vortices that result from hydrodynamic instability and current

46、 limitations of the available sensor technology, the raw pulse signal of vortex meters require time averaging. The reference flow rate at the proving facility was established by a Small Volume Prover (SVP), also referred to as Captive Displacement Prover (CDP), because proving of field meters for hy

47、drocarbon fluids was performed by portable proving systems that used SVP. The time of the proving run of a SVP normally used to calibrate 4-in. (100-mm) meters was inadequate for the time-averaged proving run required for the flow rate range of the liquid vortex meters. The laboratory proving setup

48、duplicated the portable field proving system. In order to achieve repeatable meter factors (MF) and laboratory and field proving of vortex meters, the MF of the meter being tested was established by utilizing the transfer proving method. The master meter (MM) for the transfer proving was the liquid

49、turbine meter, whose MF was established by the SVP. At the proving facility, the MM, meter being tested, and SVP, were installed in series.In the field, the performance of the vortex meter for hydrocarbon flows were established against the field flowmeter as the master meter, after the field meter was flow calibrated by the portable proving system. Therefore, variations in flow rate and properties of hydrocarbon fluids for vortex meter were limited as vortex meter could only be tested for the flow rates and properties of the hydrocarbon fluids for which the field meter were being ca

展开阅读全文
相关资源
  • API SALES OF NGL & LRG-2018 2016 Sales of Natural Gas Liquids and Liquefied Refinery Gas.pdfAPI SALES OF NGL & LRG-2018 2016 Sales of Natural Gas Liquids and Liquefied Refinery Gas.pdf
  • API MPMS 9 4-2018 Manual of Petroleum Measurement Standards Chapter 9 4-Continuous Density Measurement Under Dynamic (Flowing) Conditions (FIRST EDITION).pdfAPI MPMS 9 4-2018 Manual of Petroleum Measurement Standards Chapter 9 4-Continuous Density Measurement Under Dynamic (Flowing) Conditions (FIRST EDITION).pdf
  • API MPMS 9 3-2012 Manual of Petroleum Measurement Standards Chapter 9 3 Standard Test Method for Density Relative Density and API Gravity of Crude Petroleum and.pdfAPI MPMS 9 3-2012 Manual of Petroleum Measurement Standards Chapter 9 3 Standard Test Method for Density Relative Density and API Gravity of Crude Petroleum and.pdf
  • API MPMS 9 2-2012 Manual of Petroleum Measurement Standards Chapter 9 2 Standard Test Method for Density or Relative Density of Light Hydrocarbons by Pressure H.pdfAPI MPMS 9 2-2012 Manual of Petroleum Measurement Standards Chapter 9 2 Standard Test Method for Density or Relative Density of Light Hydrocarbons by Pressure H.pdf
  • API MPMS 9 1-2012 Manual of Petroleum Measurement Standards Chapter 9 1 Standard Test Method for Density Relative Density or API Gravity of Crude Petroleum and .pdfAPI MPMS 9 1-2012 Manual of Petroleum Measurement Standards Chapter 9 1 Standard Test Method for Density Relative Density or API Gravity of Crude Petroleum and .pdf
  • API MPMS 8 5-2015 Manual of Petroleum Measurement Standards Chapter 8 5 Standard Practice for Manual Piston Cylinder Sampling for Volatile Crude Oils Condensate.pdfAPI MPMS 8 5-2015 Manual of Petroleum Measurement Standards Chapter 8 5 Standard Practice for Manual Piston Cylinder Sampling for Volatile Crude Oils Condensate.pdf
  • API MPMS 8 5 SPANISH-2015 Manual of Petroleum Measurement Standards Chapter 8 5 - Standard Practice for Manual Piston Cylinder Sampling for Volatile Crude Oils .pdfAPI MPMS 8 5 SPANISH-2015 Manual of Petroleum Measurement Standards Chapter 8 5 - Standard Practice for Manual Piston Cylinder Sampling for Volatile Crude Oils .pdf
  • API MPMS 8 4-2017 Manual of Petroleum Measurement Standards Chapter 8 4 Standard Practice for Sampling and Handling of Fuels for Volatility Measurement (FOURTH .pdfAPI MPMS 8 4-2017 Manual of Petroleum Measurement Standards Chapter 8 4 Standard Practice for Sampling and Handling of Fuels for Volatility Measurement (FOURTH .pdf
  • API MPMS 8 4-2014 Manual of Petroleum Measurement Standards Chapter 8 4 Standard Practice for Sampling and Handling of Fuels for Volatility Measurement (THIRD E.pdfAPI MPMS 8 4-2014 Manual of Petroleum Measurement Standards Chapter 8 4 Standard Practice for Sampling and Handling of Fuels for Volatility Measurement (THIRD E.pdf
  • API MPMS 8 3-1995 Manual of Petroleum Measurement Standards Chapter 8 - Sampling Section 3 - Standard Practice for Mixing and Handling of Liquid Samples of Petr.pdfAPI MPMS 8 3-1995 Manual of Petroleum Measurement Standards Chapter 8 - Sampling Section 3 - Standard Practice for Mixing and Handling of Liquid Samples of Petr.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > API

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1