1、ANSI/ASHRAE Standard 190-2013Method of Testingfor RatingIndoor Pool DehumidifiersApproved by the ASHRAE Standards Committee on January 26, 2013; by the ASHRAE Board of Directors on January 29, 2013;and by the American National Standards Institute on May 3, 2013.ASHRAE Standards are scheduled to be u

2、pdated on a five-year cycle; the date following the standard number is the year ofASHRAE Board of Directors approval. The latest edition of an ASHRAE Standard may be purchased on the ASHRAE website(www.ashrae.org) or from ASHRAE Customer Service, 1791 Tullie Circle, NE, Atlanta, GA 30329-2305. E-mai

3、l:ordersashrae.org. Fax: 404-321-5478. Telephone: 404-636-8400 (worldwide) or toll free 1-800-527-4723 (for orders in US andCanada). For reprint permission, go to www.ashrae.org/permissions. 2013 ASHRAE ISSN 1041-2336 ASHRAE (www.ashrae.org). For personal use only. Additional reproduction, distribut

4、ion, or transmission in either print or digital form is not permitted without ASHRAEs prior written permission.SPECIAL NOTEThis American National Standard (ANS) is a national voluntary consensus standard developed under the auspices of ASHRAE.Consensus is defined by the American National Standards I

5、nstitute (ANSI), of which ASHRAE is a member and which has approved thisstandard as an ANS, as “substantial agreement reached by directly and materially affected interest categories. This signifies the concurrenceof more than a simple majority, but not necessarily unanimity. Consensus requires that

6、all views and objections be considered, and that aneffort be made toward their resolution.” Compliance with this standard is voluntary until and unless a legal jurisdiction makes compliancemandatory through legislation.ASHRAE obtains consensus through participation of its national and international

7、members, associated societies, and public review.ASHRAE Standards are prepared by a Project Committee appointed specifically for the purpose of writing the Standard. The ProjectCommittee Chair and Vice-Chair must be members of ASHRAE; while other committee members may or may not be ASHRAE members, a

8、llmust be technically qualified in the subject area of the Standard. Every effort is made to balance the concerned interests on all ProjectCommittees.The Manager of Standards of ASHRAE should be contacted for:a. interpretation of the contents of this Standard,b. participation in the next review of t

9、he Standard,c. offering constructive criticism for improving the Standard, ord. permission to reprint portions of the Standard.DISCLAIMERASHRAE uses its best efforts to promulgate Standards and Guidelines for the benefit of the public in light of available information andaccepted industry practices.

10、 However, ASHRAE does not guarantee, certify, or assure the safety or performance of any products, components,or systems tested, installed, or operated in accordance with ASHRAEs Standards or Guidelines or that any tests conducted under itsStandards or Guidelines will be nonhazardous or free from ri

11、sk.ASHRAE INDUSTRIAL ADVERTISING POLICY ON STANDARDSASHRAE Standards and Guidelines are established to assist industry and the public by offering a uniform method of testing for ratingpurposes,bysuggestingsafepracticesindesigningandinstallingequipment,byprovidingproperdefinitionsofthisequipment,andb

12、yprovidingother information that may serve to guide the industry.The creation of ASHRAE Standards and Guidelines is determined by the need for them,and conformance to them is completely voluntary.In referring to this Standard or Guideline and in marking of equipment and in advertising, no claim shal

13、l be made, either stated or implied,that the product has been approved by ASHRAE.*Denotes members of voting status when the document was approved for publicationASHRAE Standard Project Committee 190CognizantTC:TC 8.10, Mechanical Dehumidification Equipment and Heat PipesSPLS Liaison: Rita M. Harrold

14、Titu R. Doctor, Chair* Stanley A. Mumma*Harry M. Milliken, Vice Chair* Mick I. Nelson*Scotty M. Hutto, Secretary* Randy C. Schrecengost*Alois Malik* Richard W. Trent*ASHRAE STANDARDS COMMITTEE 20122013Kenneth W. Cooper, Chair Julie M. Ferguson Janice C. PetersonWilliam F. Walter, Vice-Chair Krishnan

15、 Gowri Heather L. PlattDouglass S. Abramson Cecily M. Grzywacz Ira G. PostonKarim Amrane Richard L. Hall Douglas T. ReindlCharles S. Barnaby Rita M. Harrold James R. TaubyHoy R. Bohanon, Jr. Adam W. Hinge James K. VallortSteven F. Bruning Debra H. Kennoy Craig P. WrayDavid R. Conover Jay A. Kohler C

16、harles H. Culp, III, BOD ExOSteven J. Emmerich Rick A. Larson Constantinos A. Balaras, COMark P. ModeraStephanie C. Reiniche, Manager of Standards ASHRAE (www.ashrae.org). For personal use only. Additional reproduction, distribution, or transmission in either print or digital form is not permitted w

17、ithout ASHRAEs prior written permission.CONTENTSANSI/ASHRAE Standard 190, Method of Testing for Rating Indoor Pool DehumidifiersSECTION PAGEForeword. 21 Purpose 22 Scope . 23 Instruments. 24 Airflow and Air Differential Pressure Measurement Apparatus 25 Methods of Testing and Calculation . 26 Test P

18、rocedures . 57 Data to Be Recorded 58 Test Results 89 Symbols Used in Equations 810 Reference Properties and Data 9NOTEApproved addenda, errata, or interpretations for this standard can be downloaded free of charge from the ASHRAE Web site at www.ashrae.org/technology. 2013 ASHRAE1791 Tullie Circle

19、NE Atlanta, GA 30329 www.ashrae.org All rights reserved.ASHRAE is a registered trademark of the American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.ANSI is a registered trademark of the American National Standards Institute. ASHRAE (www.ashrae.org). For personal use only.

20、Additional reproduction, distribution, or transmission in either print or digital form is not permitted without ASHRAEs prior written permission.2 ANSI/ASHRAE Standard 190-2013(This foreword is not part of this standard. It ismerely informative and does not containrequirements necessary for conforma

21、nce to thestandard. It has not been processed according to theANSI requirements for a standard and may containmaterial that has not been subject to public review ora consensus process. Unresolved objectors oninformative material are not offered the right toappeal at ASHRAE or ANSI.)FOREWORDThis Stan

22、dard was prepared under the auspices ofASHRAE. It may be used, in whole or in part, by anassociation or government agency with due credit toASHRAE. Adherence is strictly on a voluntary basis andmerely in the interests of obtaining uniform standardsthroughout the industry.1. PURPOSE The purpose of th

23、is standard is to prescribe test meth-ods for determining the moisture removal capacity andefficiency, the pool heating capacity, and sensible andtotal cooling capacity for indoor pool dehumidifiers.2. SCOPE2.1 This standard applies to indoor pool dehumidifiersusing electrically driven, mechanical v

24、apor-compressionrefrigeration systems consisting of one or more factory-made assemblies that dehumidify and circulate air andmay include pool water heating, air reheating, cooling,filtering, and heat recovery.2.2 Systems other than the above are excluded.3. INSTRUMENTS3.1 Temperature-Measuring Instr

25、uments3.1.1 All temperature measurements shall be made inaccordance with ANSI/ASHRAE Standard 41.1 StandardMethod for Temperature Measurement.3.2 Pressure-Measuring Instruments3.2.1 Pressure measurements shall be made in accor-dance with ASHRAE Standard 41.3 Standard Method forPressure Measurement.

26、3.3 Air Differential Pressureand Airflow Measurements3.3.1 The static pressure difference across nozzles andvelocity pressures at nozzle throats shall be measuredaccording to ASHRAE Standard 41.6 Standard Methodfor Measurement of Moist Air Properties.3.4 Electrical Instruments3.4.1 Electrical measur

27、ements shall be made witheither indicating or integrating instruments.3.4.2 Instruments used for measuring the electricalpower input to fan motors, compressor motors, or otherequipment accessories shall be accurate to 1.0% of theindicated value.3.4.3 Instruments used for measuring the electricalpowe

28、r input to heaters or other apparatus furnishing heatloads shall be accurate to 1.0% of the quantity mea-sured.3.4.4 Voltages shall be measured at the equipment ter-minals. Instruments used for measuring voltages shall beaccurate to 1.0% of the quantity measured.3.5 Liquid Flow Measurement3.5.1 Wate

29、r flow rates shall be measured with a liquidflowmeter or quantity meter having an accuracy of 1.0%of the indicated value in accordance with ASHRAEStandard 41.8 Standard Methods of Measurement of Flowof Liquids in Pipes Using Orifice Flowmeters.3.5.2 Condensate collection rates shall be determinedusi

30、ng a liquid quantity meter having an accuracy of 1.0%of the indicated value. 3.6 Time and Mass Measurements3.6.1 Time interval measurements shall be made withan instrument having an accuracy of 0.2% of the indicatedvalue.3.6.2 Mass measurements shall be made with an instru-ment having an accuracy of

31、 1.0% of the indicated value. 4. AIRFLOW AND AIR DIFFERENTIAL PRESSURE MEASUREMENT APPARATUS4.1 Air Enthalpy Apparatus4.1.1 Recommended configurations for the test appara-tus are provided in ASHRAE Standard 41.2 StandardMethods for Laboratory Air-Flow Measurement at thedesired wet-bulb and dry-bulb

32、temperatures.4.2 Airflow-Measuring Apparatus4.2.1 Airflow measurements shall be made in accor-dance with ASHRAE Standard 41.2 Standard Methods forLaboratory Air-Flow Measurement.4.3 External Static-Pressure Measurements.4.3.1 External static pressure shall be measured inaccordance with ASHRAE Standa

33、rd 41.2 Standard Meth-ods for Laboratory Air-Flow Measurement.5. METHODS OF TESTING AND CALCULATION5.1 Standard Test Method5.1.1 The following test method for measuring space-conditioning capacity, for all component arrangementsshown in Table 1, is covered in this standard:a. Indoor Air Enthalpy Met

34、hod.5.1.2 For the validation of the air enthalpy measure-ments, it is required to use the cooling condensate massmethod. Section 5.2 describes a method for measuringcooling condensate and determining moisture removalcapacity. Condensate mass measurements shall be 5% ofmeasurement of air enthalpy tes

35、t results. ASHRAE (www.ashrae.org). For personal use only. Additional reproduction, distribution, or transmission in either print or digital form is not permitted without ASHRAEs prior written permission.ANSI/ASHRAE Standard 190-2013 35.2 Cooling Condensate Measurement5.2.1 The latent cooling capaci

36、ty shall be determinedfrom the measurements of the condensate flow rate. Thedrain connection should be trapped to stabilize condensateflow.5.2.2 Calculations5.2.2.1 Latent cooling capacity is calculated as fol-lows:(1)5.2.2.2 The sensible cooling capacity is then calcu-lated as follows:(2)5.3 Indoor

37、 Air Enthalpy Methods5.3.1 Space-conditioning capacity is determined mea-suring airflow rate, dry-bulb temperature, and watervapor content of the air that enters and leaves the coil.Air enthalpies shall be determined in accordance withANSI/ASHRAE Standard 41.6 Standard Method forMeasurement of Moist

38、 Air Properties.5.3.2 This method shall be used for equipment havingtotal cooling capacities of less than 135,000 Btu/h(39.6 kW) and may be used for equipment with greatercapacities.5.3.3 Cooling Calculations5.3.3.1 Total, sensible, and latent indoor coolingcapacities, based on test data collected a

39、ccording to theindoor air enthalpy method, shall be calculated using thefollowing equations:1(3)(4)where(5)(6)andTABLE 1 Applicable Test Methods for Dehumidifying, Cooling, Reheating,and/or Water HeatingComponent ArrangementMethod of Heat RejectionIndoor Air Enthalpy MethodSingle-package, indoorAir

40、reheatXPool waterAir reheat and pool waterSingle-package, indoor, water-cooledAir reheatXPool waterAir reheat and pool waterA/C condenser and pool waterA/C condenserSingle-package, indoor, air-cooledAir reheatXPool waterAir reheat and pool waterA/C condenser and pool waterA/C condenserSplit-system,i

41、ndoor, air-cooledAir reheatXPool waterAir reheat and pool waterA/C condenser and pool waterA/C condenserqlci1061 wc=2.47 106wc=1The latent indoor cooling capacity is a function of the latent heatof vaporization (hfg) of water. In equations for qlci, the hfg,1061 Btu/lb (2.47106 J/kg), corresponding

42、to 57F (14C) isused. Also, the energy associated with the leaving condensate isnot included because its impact on net capacity is negligible.qsciqtciqlci=qtci60Qmiha1ha2vn-60Qmiha1ha2vn1 Wn+-=Qmiha1ha2vn-Qmiha1ha2vn1 Wn+-=qsci60Qmicpa1ta1cpa2ta2vn-=60Qmicpa1ta1cpa2ta2vn1 Wn+-=Qmicpa1ta1cpa2ta2vn-=Qm

43、icpa1ta1cpa2ta2vn1 Wn+-=cpa10.24 0.444W1+=1005 1805W1+=cpa20.24 0.444W2+=1005 1805W2+= ASHRAE (www.ashrae.org). For personal use only. Additional reproduction, distribution, or transmission in either print or digital form is not permitted without ASHRAEs prior written permission.4 ANSI/ASHRAE Standa

44、rd 190-2013(7)5.3.3.2 When the indoor air enthalpy method is used,the total and sensible cooling capacities shall be adjustedfor duct losses. The duct loss adjustment shall be added tothe total and sensible cooling capacities. The duct lossadjustment shall be calculated as follows:If the equipment i

45、ndoor section is located in the indoortest room, then(8)If the equipment indoor section is located in anoutdoor test room, then(9)5.3.4 Calculations Net Air Reheating5.3.4.1 The total heating capacity based on test datacollected according to the indoor air enthalpy methodshall be calculated using th

46、e following equation:(10)where is calculated as specified in Section 5.3.3.1 and Wn=W1=W2(11)5.3.4.2 When the indoor air enthalpy method is used,the total heating capacity shall be adjusted for the ductlosses. The duct loss adjustment shall be calculated asspecified in Section 5.3.3.1 and then subtr

47、acted algebra-ically (i.e., subtract qlossif it is positive and add qlossif itis negative) from the heating capacity determined usingthe indoor or outdoor air enthalpy method.5.3.5 Moisture-Removal-Capacity Calculations5.3.5.1 The total moisture removal capacity basedon test data collected according

48、 to the indoor air enthalpymethod shall be calculated using the following equation:(12)5.4 Airflow Rate Measurement5.4.1 Measurement MethodsAccording to RatedCooling Capacity5.4.1.1 For equipment having a rated cooling capacityless than 135,000 Btu/h (40 kW), the indoor airflow rateshall be measured using the nozzle airflow-measuring appa-ratus described in ASHRAE Standard 41.2 Standard Meth-ods for Laboratory Air-Flow M

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1