1、Designation: F2711 08 (Reapproved 2012) An American National StandardStandard Test Methods forBicycle Frames1This standard is issued under the fixed designation F2711; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of las

2、t revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods establish procedures for conductingtests to determine the structural performance properties ofbicycle

3、frames.1.2 These test methods describe mechanical tests for deter-mining the following performance properties:1.2.1 Frame FatigueHorizontal Loading,1.2.2 Frame FatigueVertical Loading, and1.2.3 Frame Impact Strength.1.3 The values stated in SI units are to be regarded asstandard. No other units of m

4、easurement are included in thisstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory

5、limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E4 Practices for Force Verification of Testing Machines3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 bicycle, ntwo-wheeled, single track, articulated ve-hicle that is solely human powered.3.1.2 bicycle fork,

6、 nstructural connection between thefront wheel and the frame.3.1.2.1 DiscussionThe fork transmits steering torque fromthe handlebars to the front wheel.3.1.3 bicycle frame, nstructural member that supports theseat with rear connection for the rear wheel, front connectionvia the head tube for the for

7、k and lower connection for thecrank/pedal assembly.3.1.4 bottom bracket shell, nstructural member of theframe that houses the assembly that supports the bearings,which support the cranks.3.1.5 crank, nlever arm that receives human energy astorque to convert into bicycle motion.3.1.6 crown race seat,

8、 nposition on the fork where thelower steering axis bearing sits.3.1.7 down tube, nlower structural connection betweenthe head tube and the bottom bracket shell.3.1.8 dropout centerline, nhub-mounting axis that passesthrough both right and left dropouts.3.1.9 front dropout, narea where the front whe

9、el hubconnects to the fork.3.1.10 head tube, nforward most structural member of theframe, which provides an interface through top, and bottombearings for the fork.3.1.10.1 DiscussionThe head tube is connected to the seattube through the top tube and the down tube.3.1.11 initial running displacement,

10、 naverage displace-ment between approximately 500 and 1000 cycles during adurability fatigue test.3.1.12 normal attitude, nintended position of the bicycleframe when in continuous straight-line motion on a flat surface.3.1.13 rake, nstraight-line distance from the front axlecenter to the perpendicul

11、ar of the steering axis.3.1.14 rear dropout, narea where the rear wheel hubconnects to the lower rear and the upper rear frame members.3.1.15 sag, namount of compression in a suspension unit,given in a percentage.3.1.16 seat post, nstructural component that connects theseat to the seat tube.3.1.17 s

12、eat tube, nstructural member of the frame intowhich the seat post inserts.3.1.18 steerer tube, nsection of the bicycle fork that ishoused within the head tube and bearing assemblies.3.1.19 top tube, nupper structural connection between thehead tube and the seat tube.1This test method is under the ju

13、risdiction of ASTM Committee F08 on SportsEquipment, Playing Surfaces, and Facilities and is the direct responsibility ofSubcommittee F08.10 on Bicycles.Current edition approved Nov. 1, 2012. Published December 2012. Originallyapproved in 2008. Last previous edition approved in 2008 as F2711 08. DOI

14、:10.1520/F2711-08.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harb

15、or Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.2 Acronyms:3.2.1 OEM, noriginal equipment from manufacturer3.3 Symbols:L = fork length, a straight-line measure from the crown raceseat to the center of the front axle. = deflection of test fork.4. Summary of Test Methods4.1 Ho

16、rizontal Loading Durability Fatigue TestThis testmethod restrains the frame at the rear dropouts (see Fig. 1). Acyclic load is applied along the x-axis at the front dropouts. Thenumber of cycles is measured. The magnitude of the load, andthe minimum number of cycles, are determined by the speci-fica

17、tion standard.4.2 Vertical Loading Durability Fatigue TestThis testmethod restrains the frame at the rear dropouts, and allows freerolling at the fork (see Fig. 2).Acyclic load is applied along theZ-axis behind the seat post. The number of cycles is measured.The magnitude of the load, and the minimu

18、m number of cycles,are determined by the specification standard.4.3 Impact Strength TestThis test method restrains theframe vertically at the rear dropouts (see Fig. 3). A mass isdropped onto a roller assembly attached to the fork. Permanentset is measured. The height of the drop is determined by th

19、especification standard.5. Significance and Use5.1 These tests are used to verify the durability and strengthof a bicycle frame.6. Apparatus6.1 Requirements for Test Forks:6.1.1 The test forks shall be designed to mount in a mannersimilar to the OEM fork, or in a manner using typical bicycleassembly

20、 procedures.6.1.2 The test forks, when mounted, shall be the samelength, L, as the longest fork designed for use with the frameand have a rake of 45 6 6 mm. When the test fork is used inplace of an OEM Suspension fork, the length is determined bythe dropout position when the suspension fork is compr

21、essedno more than 20 % of its maximum amount of travel.6.1.3 The deflection of a test fork is measured at the frontaxle center, resulting from the application of a vertical 1200 Nload at that point. The fork is fixed in position only at thesteerer tube by a v-block with minimum length of 76 mm. Thes

22、teerer tube is fixed horizontally with the crown race seatadjacent to the v-block.6.1.4 The deflection ratio for the Test fork for the HorizontalLoading Fatigue test and the Vertical Loading Fatigue test shallnot exceed the value of 1.0 when computed as follows:Deflection ratio 5K 310 000 3L3Where:K

23、 (a constant) = 1417 for L and in millimetres.(For example, a fork length of 460 mm, the maximumacceptable fork deflection () would be 6.9 mm. Similarly fora fork length of 330 mm, the maximum deflection is 2.5 mm.)6.1.5 The deflection ratio for the Test fork for the Impacttest shall not exceed the

24、value of 1.0 when computed asfollows:Deflection ratio 5K 310 000 3L3Where:K = 709 for L and in millimetres.6.2 Horizontal Loading Durability Fatigue Test:6.2.1 A fixture is required to restrain the frame at the reardropouts, while allowing free rotation about the axle (see Fig.1). In the case of a s

25、uspension frame, the suspension must belocked in a position equivalent to the manufacturers recom-mendation for sag, or 25 % sag if none was recommended. Ifthe suspension does not permit locking, then replace thesuspension unit with a solid link providing the equivalent saggeometry.6.2.2 A test fork

26、 meeting the requirements for this test (see6.1) shall be used.6.2.3 The fork shall be attached to the bicycle frame headtube using typical bicycle assembly practices.FIG. 1 Horizontal Fatigue TestF2711 08 (2012)26.2.4 The fork assembly shall be restrained at the dropoutsin such a way that allows tr

27、anslation along the X-axis, androtation about the Y-axis.6.2.5 The front and rear dropouts are to be equal in heightwhen the frame and fork assembly is fixtured.6.2.6 An actuator mounted load cell or equivalent apparatusthat is capable of providing a reversible load of constantamplitude shall be att

28、ached to the front dropouts or front axle,without constricting the rotational freedom of the fork assem-bly.6.2.7 This apparatus shall allow cyclic load application tothe front dropouts in a longitudinal direction along the bicyclecenterline.6.3 Vertical Loading Durability Fatigue Test:6.3.1 A fixtu

29、re is required to restrain the frame at the reardropouts, while allowing free rotation about the rear axle (Fig.2). In the case of a suspension frame, the suspension must belocked in a position equivalent to the manufacturers recom-mendation for sag, or 25 % sag if none was recommended. Ifthe suspen

30、sion does not permit locking, then replace thesuspension unit with a solid link providing the equivalent saggeometry.6.3.2 A test fork meeting the requirements for this test (see6.1) shall be used.6.3.3 The fork shall be attached to the bicycle frame headtube using typical bicycle assembly practices

31、.6.3.4 The fork assembly shall be restrained at the dropoutsin such a way that allows translation along the X-axis (see Fig.4); and free rotation of the fork assembly about the front axle;while movement in the Y-axis and Z-axis is constrained.6.3.5 The front and rear dropouts are to be equal heightw

32、hen the frame and fork assembly is fixtured.6.3.6 A round solid steel loading bar equivalent to a seatpost shall be inserted into the top of the seat tube, and securedto the seat tube by the manufacturers instructions using thenormal clamp. A horizontal rearward extension shall be se-curely attached

33、 to the top of this bar such that its height, h, isequal to the maximum saddle height for that particular frame,as shown in Fig. 2. The extension bar shall permit loading witha 70 mm rearward offset.6.3.7 An actuator mounted load cell or equivalent apparatusthat is capable of providing a reversible

34、load, is attached to therearward extension and aligned in the vertical, downward,direction.6.4 Impact Strength Test:6.4.1 A fixture is required to restrain the frame at the reardropouts, while holding the frame securely in a verticalorientation (Fig. 3). In the case of a suspension frame, thesuspens

35、ion must be locked in a position equivalent to themanufacturers recommendation for sag, or 25 % sag if nonewas recommended. If the suspension does not permit locking,then replace the suspension unit with a solid link providing theequivalent sag geometry.6.4.2 A test fork meeting the requirements for

36、 this test (see6.1) shall be used.6.4.3 The fork shall be attached to the bicycle frame headtube using typical bicycle assembly practices.6.4.4 The front and rear dropouts of the frame are to be onthe same vertical centerline when the frame and fork assemblyis set into the fixture.6.4.5 A free-runni

37、ng low-mass roller, 1 kg maximum, andwith a maximum diameter of 55 mm, shall be attached to thefork axle (Fig. 3).6.4.6 A free-falling, guided 22.5-kg weight shall be used toimpact the low-mass roller at a point in-line with the wheelcenterline and against the direction of bicycle motion in normalat

38、titude.7. Calibration and Standardization7.1 Durability Fatigue Tests:7.1.1 The test apparatus shall be calibrated to meet PracticesE4, for accuracy within 61 % of specified load.FIG. 2 Vertical Fatigue TestF2711 08 (2012)37.1.2 The load shall be monitored to an accuracy of 62.5 %through a load cell

39、 or other suitable load-measuring device.7.1.3 The displacement shall be monitored to within62.5 %.7.1.4 Rearward force is defined as compression (denotedwith minus () sign); forward force is defined as tension(denoted with plus (+) sign). The number of cycles is mea-sured.7.1.5 All tolerances on th

40、e test fixture shall be within 61%.7.2 Impact Test:7.2.1 The test weight shall be accurate to within 62%ofspecified weight.8. Conditioning8.1 Tests are to be performed at room temperature of 18 to35C.8.2 All tests are to be performed on initially unused frames.8.3 The same frame may be used in succe

41、ssive tests of thisstandard, except as noted in 8.5. If it does not pass a subsequenttest after passing its first test, then that particular test isinconclusive and must be repeated with an unfailed frame.8.4 No frame shall be used for the same test more than once.8.5 No frame shall be used for succ

42、essive testing after beingimpact tested, as described in 9.3.9. Procedure9.1 Horizontal Durability Fatigue Test:9.1.1 Assemble the frame onto the test apparatus, as de-scribed in 6.2.9.1.2 Begin applying the specified cyclic load at 1 Hz. Toexceeda1Hzload application rate, the following criteria mus

43、tbe met. The running displacement shall be within 63%ofthedisplacement at 1 Hz.FIG. 3 Frame Impact TestF2711 08 (2012)49.1.3 Conclude the test when the specified minimum num-ber of cycles is attained, or if/when fracture occurs. Fracture isdefined as the following:9.1.3.1 If using displacement contr

44、ol to perform the test,fracture is the point at which the load drops below 95 % of themaximum specified running load.9.1.3.2 If using force control to perform the test, fracture isa crack, tear, or separation at the surface of the frame that isvisible to the unaided eye. Inspection of the frame for

45、theexistence of fracture must occur when displacement exceeds3.0 mm from initial running displacement or previous inspec-tion.9.2 Vertical Durability Fatigue Test:9.2.1 Assemble the frame onto the test apparatus, as de-scribed in 6.3.9.2.2 Begin applying the specified cyclic load at 1 Hz. Torun the

46、test at a greater frequency than 1 Hz, the followingcriteria must be met. The running displacement shall be within63 % of the displacement at 1 Hz.9.2.3 Conclude the test when the specified minimum num-ber of cycles is attained, or if/when fracture occurs. Fracture isdefined as the following:9.2.3.1

47、 If using displacement control to perform the test,fracture is the point at which the load drops below 95 % of themaximum specified running load.9.2.3.2 If using force control to perform the test, fracture isa crack, tear, or separation at the surface of the frame that isvisible to the unaided eye.

48、Inspection of the frame for theexistence of fracture must occur when displacement exceeds3.0 mm from initial running displacement or previous inspec-tion.9.3 Impact Strength Test:9.3.1 Mount the frame and fork assembly in the verticalplane, as described in 6.4, with the front and rear dropouts onthe

49、 same vertical centerline.9.3.2 Connect the fork roller assembly to fork dropouts.9.3.3 Measure the distance between the axles (wheelbase)with the weight resting on the fork roller.9.3.4 Raise the weight to the appropriate drop height, asdefined by the specification standard.9.3.5 Release the weight onto the fork roller. The weightwill bounce (this is normal and permitted).9.3.6 After the weight comes to rest, repeat the wheelbasemeasurementthis is the permanent set of the frame and fork.10. Precision and Bias10.1 No information is presen

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1