1、ATIS-0600010.04.2017 American National Standard on Operational Vibration Requirements for Communications Equipment Alliance for Telecommunications Industry Solutions Approved May 11, 2017 Abstract This standard specifies covers the minimum operational vibration criteria for communications equipment.

2、 It is the intent of this standard to utilize the latest versions of ATIS standards that are referenced. It is also the intent to utilize (where appropriate) newer versions of other standards or documents that are referenced provided they do not conflict with the intent of this standard. ATIS-060001

3、0.04.2017 ii Foreword The information contained in this Foreword is not part of this American National Standard (ANS) and has not been processed in accordance with ANSIs requirements for an ANS. As such, this Foreword may contain material that has not been subjected to public review or a consensus p

4、rocess. In addition, it does not contain requirements necessary for conformance to the Standard. The Alliance for Telecommunication Industry Solutions (ATIS) serves the public through improved understanding between providers, customers, and manufacturers. The Sustainability in Telecom: Energy and Pr

5、otection (STEP) Committee formerly the Network Interface, Power, and Protection (NIPP) Committee engages industry expertise to develop standards and technical reports for telecommunications equipment and environments in the areas of energy efficiency, environmental impacts, power, and protection. Th

6、e work products of STEP enable vendors, operators, and their customers to deploy and operate reliable, environmentally sustainable, energy efficient communications technologies. STEP is committed to proactive engagement with national, regional, and international standards development organizations a

7、nd forums that share its scope of work. ANSI guidelines specify two categories of requirements: mandatory and recommendation. The mandatory requirements are designated by the word shall and recommendations by the word should. Where both a mandatory requirement and a recommendation are specified for

8、the same criterion, the recommendation represents a goal currently identifiable as having distinct compatibility or performance advantages. Suggestions for improvement of this document are welcome. They should be sent to the Alliance for Telecommunications Industry Solutions, STEP, 1200 G Street NW,

9、 Suite 500, Washington, DC 20005. At the time of consensus on this document, STEP, which was responsible for its development, had the following roster: E. Gallo, STEP Chair (Ericsson) J. Fuller, STEP Vice Chair (AT loose fasteners and components; deformed seals; failed, loose, or broken components;

10、mechanical misalignment; cracked or broken structures; fretting or corrosion in bearings; migration of particles or failed components; particles or failed components lodged in circuitry or mechanisms; etc. 3.1.7 Relative Humidity: The ratio, expressed in percent, of the amount of atmospheric moistur

11、e present relative to the amount that would be present if the air were saturated at a specific temperature. 3.1.8 Sweep Cycle: A traverse of the specified frequency range once in each direction (fmin to fmax to fmin constitutes one sweep cycle). 1This document is available from the Alliance for Tele

12、communications Industry Solutions (ATIS), 1200 G Street N.W., Suite 500, Washington, DC 20005. 2This document is available from the International Electrotechnical Commission. ATIS-0600010.04.2017 3 3.2 Acronyms however, actual production samples are not required. If testing is performed with pre-rel

13、ease hardware and changes occur prior to release, the changes must be analyzed to determine if they may reasonably impact the outcome of the tests. If a significant impact is indicated, the testing shall be repeated on released hardware. 4.1 Equipment Test Categories and Configurations Equipment bei

14、ng subjected to operational vibration testing shall be defined into one of the following categories. Only the test method and acceptance criteria for the selected category shall be applied throughout the testing. NOTE: These categories and configurations are taken from ATIS-0600329 and can be perfor

15、med in conjunction with earthquake resistance testing. 4.1.1 Indoor Equipment Category A Shelf level equipment 100. Bandwidth 5 Hz. Overall grms 1 dB. Sinusoidal Vibration The tolerance allowed for vibration is 1 dB. Frequency 1%. 5 Test Matrix Random vibration is usually considered to represent a m

16、ore realistic vibration characteristic compared with sinusoidal. Random vibration shall be used as the environmental parameter unless significant sinusoidal vibration is known to be present in a particular application/installation. In this case, it may be desirable to test the equipment using these

17、sinusoidal waveforms, especially if it cannot be determined if the resonant frequencies of the equipment are outside of the known vibration frequencies. In all cases, pole mounted equipment shall be tested to the sinusoidal vibration requirement. Table 5.1: Test Matrix Test Levels Indoor Location In

18、door Location Near Rotating Machinery Outdoor Location Outdoor Location Near Rotating Machinery Pole-Mounted Random Indoor Curve X Sine Indoor Curve X Random Outdoor Curve X Sine Outdoor Curve X X 6 Operational Vibration Test Methods 6.1 Test Apparatus & Support Equipment 6.1.1 Test Apparatus Shaker

19、 Tables The electrodynamic or electro hydraulic shaker table shall be capable of reproducing the Broadband random signal from 4 to 200 Hz with a tolerance of 3 dB. The test apparatus shall have sufficient capability to apply the vibration uniformly over the entire test surface. It shall also be capa

20、ble of producing single axis vibration at the required input spectrum of continuously varying amplitudes of up to 3 sigma throughout the entire frequency range of 4 to 200 Hz. ATIS-0600010.04.2017 7 Accelerometers The accelerometer shall have a minimum dynamic range of 4 to 200 Hz. Tolerance of the

21、accelerometer is 5%. Vibration Control System The vibration control system shall be capable of producing a random vibration signal with Gaussian distribution over the range of 4 to 200 Hz with a tolerance of 3 dB. The resolution of the random analysis shall be no greater than 5 Hz. If using a digita

22、l analyzer, the digitizing rate shall be 200 Hz with a total storage capacity of 30 seconds, real time. The vibration control system should be capable of accepting a correction factor to accept variances in accelerometer outputs. 6.1.2 Support Equipment Support equipment should be appropriate for co

23、ntrolling, powering, or monitoring system performance. The equipment should be capable of monitoring degradations in performance or service as appropriate for the EUT (i.e., synchronization losses, pattern losses, BER, lost cells or packets, upstream and downstream rates, etc.). ATIS-0600010.04.2017

24、 8 6.2 Random Vibration Test Method 6.2.1 Test Parameters 6.2.1.1 Inside Table 6.1: Random Vibration Test Parameters, Inside Type Slope (5-10 Hz) ASD (10-50 Hz) Slope (50-100 Hz) Axes of Vibration Duration per Axis random +12 dB/oct 0.02 m2/s3 (0.000208 g2/Hz) -12 dB/oct 3 30 min Figure 6.1: Random

25、Vibration Test Parameters, Inside 0.0010.010.111010AccelerationSpectralDensity(m2/s3)Frequency (Hz)ATIS-0600010.04.2017 9 6.2.1.2 Outside Table 6.2: Random Vibration Test Parameters, Outside Type Slope (5-10 Hz) ASD (10-50 Hz) Slope (50-100 Hz) Axes of Vibration Duration per Axis random +12 dB/oct 0

26、.04 m2/s3 (0.000416 g2/Hz) -12 dB/oct 3 30 min Figure 6.2: Random Vibration Test Parameters, Outside 6.2.2 Preconditioning Prior to testing, the equipment shall be within the ambient temperature and relative humidity ranges as defined in Table 4.1. The equipment shall be powered and verified for pro

27、per functionality. Preconditioning (or lack of) information shall be noted in the report. 0.0010.010.111010AccelerationSpectralDensity(m2/s3)Frequency (Hz)ATIS-0600010.04.2017 10 6.2.3 Test Procedure 1. Mount the EUT in its normal operating position securely on the vibration machine (per section 4.1

28、). 2. Measure the input acceleration with a suitable transducer. 3. Monitor EUT functionality during the complete duration of the test. 4. Subject the EUT to the prescribed random vibration per Test Parameters section 6.2.1. 5. Inspect the EUT for physical damage following the vibration testing. 6.

29、Repeat the test for each of three (3) mutually perpendicular axes. 6.3 Sinusoidal Vibration Test Method 6.3.1 Test Parameters 6.3.1.1 Inside Table 6.3: Sinusoidal Vibration Test Parameters, Inside Type Acceleration Amplitude & Frequency Range Axes of Vibration Duration per Axis sinusoidal 1 m/s2 (0.

30、1 g), 5-100 Hz 3 0.1 oct/min, 1 sweep cycle, 90 min Figure 6.3: Sinusoidal Vibration Test Parameters, Inside 0.111011010Acceleration(m/S2)Frequency (Hz)ATIS-0600010.04.2017 11 6.3.1.2 Outside Table 6.4: Sinusoidal Vibration Test Parameters, Outside Type Displacement & Frequency Range Acceleration Am

31、plitude & Frequency Range Axes of Vibration Duration per Axis Sinusoidal 1.2 mm (0.047 in.), 5-9 Hz 4 m/s2 (0.4 g), 9-200 Hz 3 1 oct/min, 5 sweep cycles Figure 6.4: Sinusoidal Vibration Test Parameters, Outside 6.3.2 Preconditioning Prior to testing, the equipment shall be within the ambient tempera

32、ture and relative humidity ranges as defined in Table 4.1. The equipment shall be powered and verified for proper functionality. Preconditioning (or lack of) information shall be noted in the report. 6.3.3 Test Procedure 1. Mount the EUT in its normal operating position securely on the vibration mac

33、hine (per section 4.1). 2. Measure the input acceleration with a suitable transducer. 3. Monitor EUT functionality during the complete duration of the test. 4. Subject the EUT to the prescribed sinusoidal vibration per Test Parameters section 6.3.1. 5. Inspect the EUT for physical damage following t

34、he vibration testing. 6. Repeat the test for each of three (3) mutually perpendicular axes. 1101 10 100 1000Acceleration(m/s2)Frequency (Hz)ATIS-0600010.04.2017 12 6.4 Test Report Requirements Test reports shall include the following items at a minimum: Description of EUT including names, model numb

35、ers, board revisions, etc. Description of the standards/requirements being tested to (ATIS-0600010.04). Test methodology. Pictures of the EUT, and the test bed setup. Description of the test setup, including interfaces and functionality that were monitored and what interfaces were not monitored and

36、the rationale as to why. Diagrams of the test bed setup. Engineering judgments or assumptions. All relevant test data (including photographs of visible damage). Description of the pass/fail criteria utilized and the results. Vibration plots. Equipment List for support/test equipment utilized. Calibration information. Anomalies (if any). Location of equipment within the cabinet/enclosure under test. Block Diagrams or Schematics. Operating procedures of the equipment functionality.

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf