1、AWWA Standard SM Hydraulic and Pneumatic Cylinder and Vane-Type Actuators for Valves and Slide Gates Effective date: Sept. 1, 2016. First edition approved by AWWA Board of Directors Jan. 27, 2008. This edition approved Jan. 16, 2016. Approved by American National Standards Institute Jan. 8, 2016. AN

2、SI/AWWA C541-16 (Revision of ANSI/AWWA C541-08) Copyright 2016 American Water Works Association. All Rights Reserved.ii AWWA Standard This document is an American Water Works Association (AWWA) standard. It is not a specification. AWWA standards describe minimum requirements and do not contain all o

3、f the engineering and administrative information normally contained in specifications. The AWWA standards usually contain options that must be evaluated by the user of the standard. Until each optional feature is specified by the user, the product or service is not fully defined. AWWA pub- lication

4、of a standard does not constitute endorsement of any product or product type, nor does AWWA test, certify, or approve any product. The use of AWWA standards is entirely voluntary. This standard does not supersede or take precedence over or displace any applicable law, regulation, or code of any gove

5、rnmental authority. AWWA standards are intended to represent a consensus of the water industry that the product described will provide satisfactory ser- vice. When AWWA revises or withdraws this standard, an official notice of action will be placed on the first page of the Official Notice section of

6、 Journal American Water Works Association. The action becomes effective on the first day of the month following the month of Journal American Water Works Association publication of the official notice. American National Standard An American National Standard implies a consensus of those substantiall

7、y concerned with its scope and provisions. An American National Standard is intended as a guide to aid the manufacturer, the consumer, and the general public. The existence of an American National Standard does not in any respect preclude anyone, whether that person has ap - proved the standard or n

8、ot, from manufacturing, marketing, purchasing, or using products, processes, or procedures not conforming to the standard. American National Standards are subject to periodic review, and users are cautioned to obtain the latest editions. Producers of goods made in conformity with an American Nationa

9、l Standard are encour - aged to state on their own responsibility in advertising and promotional materials or on tags or labels that the goods are produced in conformity with particular American National Standards. Caution n oti Ce : The American National Standards Institute (ANSI) approval date on

10、the front cover of this standard indicates completion of the ANSI approval process. This American National Standard may be revised or withdrawn at any time. ANSI procedures require that action be taken to reaffirm, revise, or withdraw this standard no later than five years from the date of publicati

11、on. Purchasers of American National Standards may receive current information on all standards by calling or writing the American National Standards Institute, 25 West 43rd Street, Fourth Floor, New York, NY 10036; 212.642.4900; or emailing infoansi.org. ISBN-13, print: 978-1-62576-143-9 eISBN-13, e

12、lectronic: 978-1-61300-368-8DOI: http:/dx.doi.org/10.12999/AWWA.C541.16 All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopy, recording, or any information or retrieval system, except in the form

13、of brief excerpts or quotations for review purposes, without the written permission of the publisher. Copyright 2016 by American Water Works Association Printed in USA hours of work by your fellow water professionals. Revenue from the sales of this AWWA material supports ongoing product development.

14、 Unauthorized distribution, either electronic or photocopied, is illegal and hinders AWWAs mission to support the water community. This AWWA content is the product of thousands of Copyright 2016 American Water Works Association. All Rights Reserved.iii Committee Personnel The AWWA Standards Subcommi

15、ttee on Hydraulic and Pneumatic Actuators, which reviewed and approved this standard, had the following personnel at the time of approval: Mike Ford, Chair J.V. Ballun, Val-Matic Valve (2) if threaded, thread type, pitch, and lead; (3) dimensions of stem and keyway (if applicable); and (4) orientati

16、on (i.e., clockwise to close or clock- wise to open). d. Weight of gate and stem for slide gate. Copyright 2016 American Water Works Association. All Rights Reserved.ix e. Failure mode on loss of power: fail open, fail close, fail freeze, or fail in last position on loss of driver medium pressure, c

17、ontrol signal, or both. f. Seating/unseating torque in foot-pounds (newton-meters), maximum dynamic torque in foot-pounds (newton-meters), and when applicable, thrust in pounds (newtons) (Sec. 4.3.1.3). g. Minimum hydraulic or pneumatic pressure available for sizing actuator (Sec. 4.3.1.2). h. Maxim

18、um torque/thrust capability of the valve or slide gate (Sec. 4.3.2). i. Direction of rotation of actuator handwheel to open valve or slide gate if other than counterclockwise (Sec. 4.4.10.8). 4. Specific actuator and equipment data. See Table A.1, Actuator Data Form, appendix A. a. Special auxiliari

19、es, such as fail-safe, spring-return pneumatic (Sec. 4.4.7 .1 5, 4.4.8.12, and 4.4.9.7), or manual (mechanical) override (Sec. 4.4.10). i. Fail-safe operation using a spring-return option allows a valve/ actuator assembly to “fail” to a specified position, usually fully closed or fully open, on loss

20、 of driver medium pressure. For rotary valves, the rotation of the spring stroke must be specified in the purchase documents. ii. Spring-return actuators and cylinders have a “starting torque” and “ending torque.” Starting torque refers to the torque output of the actuator or cylinder at the beginni

21、ng of the air stroke or spring stroke, as specified in the manufacturers literature. Ending torque refers to the torque output of the actuator or cylinder at the end of the air stroke or spring stroke, as specified in the manufacturers literature. Some actuators and cylinders have different starting

22、 torques and ending torques for the air and spring strokes. iii. Declutchable manual gear override. When specified by the pur- chaser, a declutchable manual gear override shall be provided. The user may consider a declutchable manual gear override with a handwheel when there may be the need of manua

23、lly operating a valve equipped with a hydraulic or pneumatic actuator, for example, in the event of a power outage. For rotary valves, it is good practice to mount the manual gear override between the hydraulic or pneumatic actuator and the valve to provide true stand-alone capability in the event o

24、f actuator failure or servicing. Handwheel rim pull force is determined by the effort required on the handwheel to operate the valve or gate closure member. Where the handwheel is a spoke design rather than a rim design, handwheel input force should be measured at 2 in. from the far end of the spokes. While this standard limits handwheel rim pull (Sec. 4.4.7 .16 and Copyright 2016 American Water Works Association. All Rights Reserved.

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1