1、NEMA Standards PublicationNational Electrical Manufacturers AssociationANSI C136.31-2010 Roadway and AreaLighting Equipment Luminaire VibrationANSI C136.31-2010 American National Standard for Roadway and Area Lighting Equipment Luminaire Vibration Secretariat: National Electrical Manufacturers Assoc
2、iation Approved January 4, 2011 American National Standards Institute, Inc. ANSI C136.31-2010 NOTICE AND DISCLAIMER The information in this publication was considered technically sound by the consensus of persons engaged in the development and approval of the document at the time it was developed. C
3、onsensus does not necessarily mean that there is unanimous agreement among every person participating in the development of this document. ANSI standards and guideline publications, of which the document contained herein is one, are developed through a voluntary consensus standards development proce
4、ss. This process brings together volunteers and/or seeks out the views of persons who have an interest in the topic covered by this publication. While NEMA administers the process to promote fairness in the development of consensus, it does not write the document and it does not independently test,
5、evaluate, or verify the accuracy or completeness of any information or the soundness of any judgments contained in its standards and guideline publications. NEMA disclaims liability for any personal injury, property, or other damages of any nature whatsoever, whether special, indirect, consequential
6、, or compensatory, directly or indirectly resulting from the publication, use of, application, or reliance on this document. NEMA disclaims and makes no guaranty or warranty, express or implied, as to the accuracy or completeness of any information published herein, and disclaims and makes no warran
7、ty that the information in this document will fulfill any of your particular purposes or needs. NEMA does not undertake to guarantee the performance of any individual manufacturer or sellers products or services by virtue of this standard or guide. In publishing and making this document available, N
8、EMA is not undertaking to render professional or other services for or on behalf of any person or entity, nor is NEMA undertaking to perform any duty owed by any person or entity to someone else. Anyone using this document should rely on his or her own independent judgment or, as appropriate, seek t
9、he advice of a competent professional in determining the exercise of reasonable care in any given circumstances. Information and other standards on the topic covered by this publication may be available from other sources, which the user may wish to consult for additional views or information not co
10、vered by this publication. NEMA has no power, nor does it undertake to police or enforce compliance with the contents of this document. NEMA does not certify, test, or inspect products, designs, or installations for safety or health purposes. Any certification or other statement of compliance with a
11、ny health or safetyrelated information in this document shall not be attributable to NEMA and is solely the responsibility of the certifier or maker of the statement. ANSI C136.31-2010 AMERICAN NATIONAL STANDARD Approval of an American National Standard requires verification by ANSI that the require
12、ments for due process, consensus, and other criteria for approval have been met by the standards developer. Consensus is established when, in the judgment of the ANSI Board of Standards Review, substantial agreement has been reached by directly and materially affected interests. Substantial agreemen
13、t means much more than a simple majority, but not necessarily unanimity. Consensus requires that all views and objections be considered, and that a concerted effort be made toward their resolution. The use of American National Standards is completely voluntary; their existence does not in any respec
14、t preclude anyone, whether he has approved the standards or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not conforming to the standards. The American National Standards Institute does not develop standards and will in no circumstances give an interpret
15、ation of any American National Standard. Moreover, no person shall have the right or authority to issue an interpretation of an American National Standard in the name of the American National Standards Institute. Requests for interpretations should be addressed to the secretariat or sponsor whose na
16、me appears on the title page of this standard. Caution Notice: This American National Standard may be revised or withdrawn at any time. The procedures of the American National Standards Institute require that action be taken periodically to reaffirm, revise, or withdraw this standard. Purchasers of
17、American National Standards may receive current information on all standards by calling or writing the American National Standards Institute. Published by National Electrical Manufacturers Association 1300 North 17th Street, Rosslyn, VA 22209 Copyright 2010 by National Electrical Manufacturers Assoc
18、iation All rights reserved including translation into other languages, reserved under the Universal Copyright Convention, the Berne Convention for the Protection of Literary and Artistic Works, and the International and Pan American Copyright Conventions. No part of this publication may be reproduce
19、d in any form, in an electronic retrieval system or otherwise, without the prior written permission of the publisher. Printed in the United States of America i ANSI C136.31-2010 This page intentionally left blank. ii ANSI C136.31-2010 CONTENTS 1 Scope .1 2 References .1 3 Definitions.1 3.1 Fundament
20、al Resonant Frequency1 3.2 Luminaire .1 4 Types of Vibration.1 4.1 Wind Induced Vibration1 4.2 Traffic Induced Vibration 1 5 Luminaire Vibration Test 2 iii ANSI C136.31-2010 This page intentionally left blank. iv AMERICAN NATIONAL STANDARD ANSI C136.31-2010 For Roadway and Area Lighting Equipment Lu
21、minaire Vibration 1 Scope This standard covers the minimum vibration withstand capability and vibration test methods for roadway and area luminaires. 2 References This standard is intended for use in conjunction with the following standards. When these standards are superseded by an approved revisio
22、n, the latest revision shall apply. ANSI C136.3 American National Standard for Roadway and Area Lighting EquipmentLuminaire Attachments ANSI C136.14 American National Standard for Roadway and Area Lighting EquipmentElliptically Shaped, Enclosed Side-Mounted Luminaires for Horizontal-Burning High-Int
23、ensity-Discharge Lamps ANSI C136.16 American National Standard for Roadway and Area Lighting EquipmentEnclosed, Post TopMounted Luminaires ANSI C136.18 American National Standard for Roadway and Area Lighting EquipmentHigh-Mast Side-Mounted Luminaires for Horizontal- or Vertical-Burning High-Intensi
24、ty Discharge Lamps 3 Definitions 3.1 Fundamental Resonant Frequency The lowest resonant frequency where the response is in phase with the excitation. 3.2 Luminaire A complete lighting unit consisting of a lamp or lamps, or solid state light source, together with the parts designed to distribute the
25、light, to position and protect the lamp(s), and to connect the lamp(s) to the power supply. 4 Types of Vibration Roadway luminaires may experience several types of externally induced vibration. This standard is not intended to cover natural or catastrophic disasters. 4.1 Wind Induced Vibration Wind
26、can induce vibration in lighting systems that consist of luminaire, arm, and pole assemblies. The magnitude of this type of vibration is mostly a function of the size, shape, and rigidity of the luminaire and pole system and damping of the system. 4.2 Traffic Induced Vibration Traffic induced vibrat
27、ion can be transferred to the luminaire system from a roadway, bridge, or overpass, being generated by the passage of vehicles. A similar type of vibration can occur in areas near heavy dynamic equipment. 1 ANSI C136.31-2010 5 Luminaire Vibration Test The luminaire vibration test is designed to dete
28、rmine whether the luminaire is able to withstand vibration conditions that may be encountered in normal installations. The test is a mechanical performance evaluation. Therefore, the luminaire is not normally energized during the test. A lamp shall be installed in the luminaire for this test. The te
29、st criteria were developed with consideration to the effect of wind and traffic induced vibration. The luminaire shall be attached as it would be mounted in the field to a vibration table capable of withstanding the loads and forces encountered during the test and tested in a manner to simulate a no
30、rmal installation. The luminaire shall be vibrated at or near fundamental resonant frequency. This frequency shall be determined for each of the three mutually perpendicular planes (x, y, and z) and should be between 2 and 30 hertz. The acceleration intensity measured at the luminaires center of gra
31、vity shall be as specified in the corresponding levels as shown below. Level 1 should be used for normal roadway applications. Level 2 should be used for bridge and overpass applications. If the luminaire housing utilizes several different materials in its construction, the worst case criteria from
32、the tables shall be used in the testing. During the vibration test, the frequency and displacement should be monitored. A major change in frequency or displacement is an indication of structural failure. The luminaire shall be capable of withstanding the described vibration for 100,000 cycles in eac
33、h plane. A separate sample luminaire may be used for each plane to eliminate the effect of conjunctive material fatigue. Other test amplitudes and durations may be negotiated between the specifier and supplier as needed to simulate extreme fatigue. At the test conclusion, the luminaire shall meet it
34、s original specification. There shall be no damage to the enclosure, reduction of electrical spacings, or loosening of any part of the luminaire. If the light source is integral to the luminaire, it shall be fully operational at test completion. Vibration Test Level 1Normal Applications All material
35、s shall be 1.5 G (14.67 m/s2) Vibration Test Level 2Bridge/Overpass Applications All materials shall be 3.0 G (29.4 m/s2) 2 NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION 1300 NORTH 17TH STREET, SUITE 900 ROSSLYN. VA 22209www.NEMA.orgTO ORDER ADDITIONAL NEMA STANDARDS VISITWWW.GLOBAL.IHS.COM OR CALL 1-800-854-7179/1-303-397-79565612_0514TB