1、NEMA Standards PublicationNational Electrical Manufacturers AssociationNEMA C82.1-2004 (R2015)Lamp Ballasts LineFrequency FluorescentLamp BallastsC82.1-2004 (R2008, R2015) American National Standard for Lamp Ballasts Line Frequency Fluorescent Lamp Ballasts Secretariat: National Electrical Manufactu

2、rers Association Approved: November 20, 2015 American National Standards Institute, Inc.ANSI C82.1-2004 (R2008, R2015) Page i 2015 National Electrical Manufacturers Association NOTICE AND DISCLAIMER The information in this publication was considered technically sound by the consensus of persons enga

3、ged in the development and approval of the document at the time it was developed. Consensus does not necessarily mean that there is unanimous agreement among every person participating in the development of this document. ANSI standards and guideline publications, of which the document contained her

4、ein is one, are developed through a voluntary consensus standards development process. This process brings together volunteers and/or seeks out the views of persons who have an interest in the topic covered by this publication. While NEMA administers the process to promote fairness in the developmen

5、t of consensus, it does not write the document and it does not independently test, evaluate, or verify the accuracy or completeness of any information or the soundness of any judgments contained in its standards and guideline publications. NEMA disclaims liability for any personal injury, property,

6、or other damages of any nature whatsoever, whether special, indirect, consequential, or compensatory, directly or indirectly resulting from the publication, use of, application, or reliance on this document. NEMA disclaims and makes no guaranty or warranty, expressed or implied, as to the accuracy o

7、r completeness of any information published herein, and disclaims and makes no warranty that the information in this document will fulfill any of your particular purposes or needs. NEMA does not undertake to guarantee the performance of any individual manufacturer or sellers products or services by

8、virtue of this standard or guide. In publishing and making this document available, NEMA is not undertaking to render professional or other services for or on behalf of any person or entity, nor is NEMA undertaking to perform any duty owed by any person or entity to someone else. Anyone using this d

9、ocument should rely on his or her own independent judgment or, as appropriate, seek the advice of a competent professional in determining the exercise of reasonable care in any given circumstances. Information and other standards on the topic covered by this publication may be available from other s

10、ources, which the user may wish to consult for additional views or information not covered by this publication. NEMA has no power, nor does it undertake to police or enforce compliance with the contents of this document. NEMA does not certify, test, or inspect products, designs, or installations for

11、 safety or health purposes. Any certification or other statement of compliance with any health- or safety-related information in this document shall not be attributable to NEMA and is solely the responsibility of the certifier or maker of the statement. ANSI C82.1-2004 (R2008, R2015) Page i 2015 Nat

12、ional Electrical Manufacturers Association AMERICAN NATIONAL STANDARD Approval of an American National Standard requires verification by the American National Standards Institute, Inc. (ANSI) that the requirements for due process, consensus, and other criteria for approval have been met by the stand

13、ards developer. An American National Standard implies a consensus of those substantially concerned with its scope and provisions. Consensus is established when, in the judgment of the ANSI Board of Standards Review, substantial agreement has been reached by directly, and materially affected interest

14、s. Substantial agreement means much more than a simple majority, but not necessarily unanimity. Consensus requires that all views and objections be considered, and that a concerted effort be made toward their resolution. The existence of an American National Standard does not in any respect preclude

15、 anyone, whether s/he has approved the standard or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not conforming to the standards. It is intended as a guide to aid the manufacturer, the consumer, and the general public. ANSI does not develop standards and

16、 will in no circumstances give an interpretation of any American National Standard. Moreover, no person shall have the right or authority to issue an interpretation of an American National Standard in the name of the ANSI. Requests for interpretations should be addressed to the secretariat or sponso

17、r whose name appears on this title page. CAUTION NOTICE: This American National Standard may be revised or withdrawn at any time. The procedures of ANSI require that action be taken periodically to reaffirm, revise, or withdraw this standard. Purchasers of American National Standards may receive cur

18、rent information on all standards by calling or writing ANSI. Published by National Electrical Manufacturers Association 1300 North 17thStreet, Suite 900 Rosslyn, Virginia 22209 2015 National Electrical Manufacturers Association All rights, including translation into other languages, reserved under

19、the Universal Copyright Convention, the Berne Convention for the Protection of Literary and Artistic Works, and the International and Pan American copyright conventions. No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without prior written p

20、ermission of the publisher. Printed in the United States of America ANSI C82.1-2004 (R2008, R2015) Page ii 2015 National Electrical Manufacturers Association FOREWORD (This Foreword is not part of American National Standard C82.1-2004.)Suggestions for improvement of this standard are welcome. They s

21、hould be submitted to Secretariat C82 National Electrical Manufacturers Association 1300 North 17thStreet, Suite 900 Rosslyn, Virginia 22209 This standard was processed and approved for submittal to ANSI by the Accredited Standards Committee on Lamp Ballasts, C82, and its Working Group C82 WG01. App

22、roval of the standard does not necessarily imply that all working group members voted for its approval. ANSI C82.1-2004 (R2008, R2015) Page iii 2015 National Electrical Manufacturers Association Contents 1. Scope 1 2. Normative References 1 3. Definitions . 2 4. Ballast Marking . 2 4.1 Marking 2 4.2

23、 Color coding of Ballasts Leads 2 5. Ballast Performance . 4 5.1 General 4 5.2 Starting Conditions 4 5.3 Ballast Output 7 5.4 Cathode Preheating Current . 9 5.5 Regulation . 9 5.6 Operating-Current Waveshape 9 5.7 Supplementary Cathode Heating . 10 5.8 Voltage across Starter Terminals . 10 5.9 Radio

24、-Interference Suppression 11 5.10 Ballast Safety 11 6. Design Center Voltages . 11 7. Application Requirements 12 7.1 Limits for Contact Resistance . 12 7.2 Operating Temperature Limits 12 7.3 Supply Voltage Limits 12 7.4 Equipment Grounding 12 7.5 Audible Sound Level 13 ANSI C82.1-2004 (R2008, R201

25、5) Page iv 2015 National Electrical Manufacturers Association TABLES Table 1 - Color Coding for Multi-lamp Ballast Leads 4 Table 2 - Required Starting Current for Instant-Start Ballasts . 6 Table 3 - Required Starting Current for Two-Lamp Series-Sequence Type Ballasts for 96-Inch T-12 Instant-Start

26、Lamps . 6 Table 4 - Required Starting Current for Two-Lamp Series-Sequence Type Ballasts for 48-Inch T-12, 40-Watt T-12, or 40-Watt T-17, Instant-Start Lamps . 7 Table 5 - Tolerances of Minimum Ballast Factor and Current Requirements for Switch-Start and Instant-Start Ballasts 7 Table 6 - Tolerance

27、of Minimum Ballasts Factor for Rapid Start Circuits 8 Table 7 - Maximum RMS Volts across Starter Terminals 11 Table 8 - Design Center Input Voltages . 11 Table 9 - Maximum Contact Resistance 12 ANSI C82.1-2004 (R2008, R2015) Page 1 2015 National Electrical Manufacturers Association 1. ScopeThis stan

28、dard is intended to cover ballasts which have rated open-circuit voltages of 2000 volts1or less and are intended to operate lamps at a frequency of 50 Hz or 60 Hz.2This comprises ballasts for hot-cathode fluorescent lamps, either switch-start (preheat-start), rapid-start (continuously heated cathode

29、s), modified rapid start (cathode cutout), or instant-start, and also ballasts for cold-cathode fluorescent lamps, used primarily for lighting purposes, which come within this voltage range. The ballast and lamp combinations covered by this specification normally are intended for use in room ambient

30、 temperatures of 10C to 40C. At ambient temperatures outside this range, certain special operating characteristics may be required. 2. Normative ReferencesThis standard is intended to be used in conjunction with the following American National Standards. When these standards are superseded by a revi

31、sion approved by the American National Standards Institute, Inc., the revision shall apply: ANSI/NFPA 70 National Electrical Code ANSI C78.81-2003 Double-capped Fluorescent Lamps Dimensional and Electrical Characteristics ANSI C78.901-2001 Single base Fluorescent Lamps Dimensional and Electrical Cha

32、racteristics ANSI C82.2-2002 Fluorescent Lamp Ballasts - Methods of Measurement ANSI C82.3-2002 Reference Ballasts for Fluorescent Lamps ANSI C82.11-2002 High Frequency Fluorescent Lamp Ballasts ANSI C82.13-2002 Definitions for Fluorescent Lamps and Ballasts ANSI/UL 935-2001 Standards for Safety - F

33、luorescent Lamp Ballasts 1. See ANSI/NFPA 70 or related standards for requirements for various voltage classifications.2. See ANSI C82.11-2002 for high frequency fluorescent ballast specifications.ANSI C82.1-2004 (R2008, R2015) Page 2 2015 National Electrical Manufacturers Association 3. Definitions

34、See ANSI C82.13 for related definitions. 4. Ballast Marking4.1 Marking Ballasts shall be marked to indicate the supply voltage and frequency, the input current, the manufacturer, the ballast type designation, and the number, type, and wattage or current of fluorescent lamps the ballast shall operate

35、. 4.1.1 Power Factor. Ballasts operating with an average power factor of 90% or above shall be labeled as high-power factor type. Ballasts of the corrected type and operating at a power factor of less than 90% shall indicate the average operating power factor. Ballasts of the uncorrected type need n

36、ot be marked for power factor. 4.1.2 Open-Circuit Voltage. The value of the open-circuit voltage, when over 300 volts, shall be marked. 4.1.3 Required Grounding. All ballasts providing voltages in excess of 150 volts shall be marked to indicate that the ballast case must be grounded. 4.1.4 Supplemen

37、tary Marking. Except for single-lamp series-reactor type ballasts, supplementary marking shall be included to indicate the correct point of connection for various leads. Any necessary restrictions or conditions concerning operation of a ballast shall be so indicated as part of the supplementary mark

38、ing. 4.2 Color Coding of Ballasts Leads 4.2.1 Line Leads. The following color coding shall be used for the line leads of ballasts: (1) On ballasts with only one line lead, such as the series-reactor type, the lead shall be black.(2) On ballasts with two line leads, when one lead connects to a neutra

39、l wire, that lead shallbe white or natural gray and the other shall be black.3(3) On ballasts with two line leads, which connect to ungrounded supply lines, both leads shallbe black.3 For single identification of single lamp ballast leads in switching schemes, a 15% or less white tracer stripe may b

40、e used on the black lead.ANSI C82.1-2004 (R2008, R2015) Page 3 2015 National Electrical Manufacturers Association 4.2.2 Lamp Leads. The following color coding is for the lamp lead of ballasts: (1) On single-lamp series-reactor type ballast, the lamp lead shall be blue.(2) An unprotected version of a

41、 single-lamp series reactor type ballast, the lamp lead shallhave the option to be black.(3) On a single-lamp or multi-lamp ballast (except series-reactor type) where lamps areoperated independently and lamp currents are essentially in phase with each other, the lampleads shall be blue.(4) On multi-

42、lamp ballast, where a lead-lag type circuit is used, the leading-lamp lead shall bered, and the lagging-lamp lead shall be blue.(5) On ballasts with a compensator winding, compensator leads shall be yellow-blue tracer oryellow. 4(6) On a two-lamp instant-start ballast of the series-sequence type, la

43、mp leads shall be redand blue, respectively. Circuit arrangements shall be such that red and white leads areconnected to respective ends of one lamp and black and blue leads to the other lamp. If thecircuit arrangement is such that both lamps do not connect back to the line leads, thisparagraph shal

44、l be followed insofar as possible.(7) On a single-lamp ballast of the continuously heated cathode type (rapid-start), the leads tothat lamp cathode operated at the maximum voltage with reference to either of the line leadsshall be red. The leads to the cathode at the other extreme of voltage relativ

45、e to the redcathode shall be blue.(8) On multi-lamp ballast of the series-sequence continuously heated cathode type(rapid-start), the leads to that cathode operated at the maximum voltage with reference toeither of the line leads, shall be red. The leads to the cathode at the other extreme of voltag

46、erelative to the red shall be blue. For two-lamp ballasts, the leads to the pair of commoncathodes shall be either yellow-blue tracer or yellow.5When more than two lamps are involved, the leads to each cathode or pair of cathodes, beginning at the high voltage (or red) end, shall have colors used in

47、 the order shown in Table 1. 4 Choice is given depending upon the type of wire utilized by the manufacturer and its ability to be distinguished from white.5 Choice is given depending upon the type of wire utilized by the manufacturer and its ability to be distinguished from white. 2015 National Elec

48、trical Manufacturers Association ANSI C82.1-2004 (R2008, R2015) Page 44.2.3 Other Ballast Types. Ballasts not covered by 4.2.1 and 4.2.2 shall comply with these requirements insofar as possible. Table 1 Color Coding for Multi-lamp Ballasts Leads 3-Lamp* 4-Lamp* 5-Lamp* 6-Lamp*Red Red Red Red Yellow

49、Yellow Yellow Yellow Blue/White 50/50 Blue/White 50/50 Blue/White 50/50 Orange Blue Brown Brown Blue/White Blue Orange Orange/Black Blue Brown Blue *C78 specifications for more than three lamps in series are not available at present.5. Ballast Performance5.1 General Measurements necessary to determine ballast performance shall be made in accordance with ANSI C82.2. 5.2 Starting Conditions 5.2.1 Starting. For satisfactory lamp starting, a ballast, when operated at any voltage between 90% and

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1