ANSI UL 203A-2015 UL Standard for Safety Sway Brace Devices for Sprinkler System Piping (First Edition Reprint with revisions through and including June 27 2016).pdf

上传人:outsidejudge265 文档编号:439030 上传时间:2018-11-14 格式:PDF 页数:33 大小:1.23MB
下载 相关 举报
ANSI UL 203A-2015 UL Standard for Safety Sway Brace Devices for Sprinkler System Piping (First Edition Reprint with revisions through and including June 27 2016).pdf_第1页
第1页 / 共33页
ANSI UL 203A-2015 UL Standard for Safety Sway Brace Devices for Sprinkler System Piping (First Edition Reprint with revisions through and including June 27 2016).pdf_第2页
第2页 / 共33页
ANSI UL 203A-2015 UL Standard for Safety Sway Brace Devices for Sprinkler System Piping (First Edition Reprint with revisions through and including June 27 2016).pdf_第3页
第3页 / 共33页
ANSI UL 203A-2015 UL Standard for Safety Sway Brace Devices for Sprinkler System Piping (First Edition Reprint with revisions through and including June 27 2016).pdf_第4页
第4页 / 共33页
ANSI UL 203A-2015 UL Standard for Safety Sway Brace Devices for Sprinkler System Piping (First Edition Reprint with revisions through and including June 27 2016).pdf_第5页
第5页 / 共33页
亲,该文档总共33页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 203A Sway Brace Devices for Sprinkler System Piping STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTE

2、D MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Sway Brace Devices for Sprinkler System Piping, UL 203A First Edition, Dated December 18, 2015 Summary of Topics This revision to ANSI/UL 203A is being issued as an editorial upda

3、te, which includes a correction to the table referenced in ASTM A1023/A1023M, and a correction in the column labeled Pipe Size , Table 9.2. The corrected requirements are substantially in accordance with Proposal(s) on this subject dated April 10, 2015 and September 25, 2015. Text that has been chan

4、ged in any manner or impacted by ULs electronic publishing system is marked with a vertical line in the margin. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, o

5、r otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, conseque

6、ntial, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liabi

7、lity for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including re

8、asonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. JUNE 27, 2016 UL 203A tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JUNE 27,

9、2016 UL 203A tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL DECEMBER 18, 2015 (Title Page Reprinted: June 27, 2016) 1 UL 203A Standard for Sway Brace Devices for Sprinkler System Piping Prior to the rst edition, the

10、requirements for the products covered by this standard were included in the Outline of Investigation for Sway Brace Devices for Sprinkler System Piping, UL 203A. First Edition December 18, 2015 This ANSI/UL Standard for Safety consists of the First Edition including revisions through June 27, 2016.

11、The most recent designation of ANSI/UL 203A as an American National Standard (ANSI) occurred on December 18, 2015. ANSI approval for a standard does not include the Cover Page, Transmittal Pages and Title Page. Comments or proposals for revisions on any part of the Standard may be submitted to UL at

12、 any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all c

13、opyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2016 UNDERWRITERS LABORATORIES INC. ANSI/UL 203A-2015UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL DECEMBER 18, 2015

14、SWAY BRACE DEVICES FOR SPRINKLER SYSTEM PIPING - UL 203A 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .4 2 Components 4 3 Units of Measurement .4 4 Undated References 4 5 Glossary .5 CON

15、STRUCTION 6 General 7 7 Materials .8 8 Protective Coatings .9 PERFORMANCE 9 Load Test 9 10 Zinc Coating Thickness Test for Cable 17 11 Metallic Coating Thickness Tests .17 12 Restraint Device Load Test 19 13 Assembly Test of Sway Brace Fitting 19 14 Torque Test of Shear Bolts 20 MARKINGS 15 General

16、20 INSTALLATION INSTRUCTIONS 16 General 21 Appendix A A1 Examples of Sway Brace Devices A1 DECEMBER 18, 2015 SWAY BRACE DEVICES FOR SPRINKLER SYSTEM PIPING - UL 203A 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 T

17、hese requirements cover sway brace devices intended to protect re protection system piping in locations subject to earthquakes. These devices are intended for installation in accordance with the Standard for the Installation of Sprinkler Systems, NFPA 13. 1.2 These requirements cover restraint devic

18、es intended to restrict movement of re protection piping. 2 Components 2.1 Except as indicated in 2.2, a component of a product covered by this Standard shall comply with the requirements for that component. 2.2 A component is not required to comply with a specic requirement that: a) Involves a feat

19、ure or characteristic not required in the application of the component in the product covered by this standard, or b) Is superseded by a requirement in this standard. 2.3 A component shall be used in accordance with its rating established for the intended conditions of use. 2.4 Specic components are

20、 incomplete in construction features or restricted in performance capabilities. Such components are intended for use only under limited conditions, such as certain temperatures not exceeding specied limits, and shall be used only under those specic conditions. 3 Units of Measurement 3.1 Values state

21、d without parentheses are the requirement. Values in parentheses are explanatory or approximate information. 4 Undated References 4.1 Any undated reference to a code or standard appearing in the requirements of this standard shall be interpreted as referring to the latest edition of that code or sta

22、ndard. DECEMBER 18, 2015 SWAY BRACE DEVICES FOR SPRINKLER SYSTEM PIPING - UL 203A 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 5 Glossary 5.1 For the purposes of this Standard, the following denitions apply. 5.2 BRACE MEMBER Structural c

23、omponent of a sway brace. 5.3 BRACE MEMBER NON-RIGID Standard Specication for Stranded Carbon Steel Wire Ropes for General Purposes, ASTM A1023/A1023M, Table 7, Galvanized Steel Cable, as referenced by Standard Guidelines for the Structural Applications of Steel Cables for Buildings, ASCE-19. 5.4 FA

24、STENER ADAPTER Device to facilitate the use of additional fasteners for mounting a sway brace (See Figure A.4). 5.5 LOAD RATING, NONRIGID ASSEMBLY The published load rating is less than or equal to the manufacturers specied minimum breaking strength of the cable divided by 1.5. 5.6 LOAD RATING, RIGI

25、D SWAY BRACE FITTINGS The published maximum force to be applied to a component of a rigid sway brace. 5.7 NPS (NOMINAL PIPE SIZE) A dimensionless designator for pipe sizes dened in standards including: a) Standard Specication for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and Seamless, A

26、STM A53/A53M; b) Standard Specication for Electric-Resistance-Welded Steel Pipe, ASTM A135/A135M; and c) Standard Specication for Black and Hot-Dipped Zinc-Coated (Galvanized) Welded and Seamless Steel Pipe for Fire Protection Use, ASTM A795/A795M used to replace terms such as “Nominal Diameter” and

27、 “Nominal Size.” 5.8 PERMANENT DEFORMATION The distortion of a system pipe or brace member in excess of the requirements in Table 13.1. 5.9 RESTRAINT DEVICE A mechanism that is a part of a hanger assembly or a separate device and is intended to limit interaction of the pipe with other portions of th

28、e structure and to limit stresses in the pipes to permissible limits. 5.10 RIGID SWAY BRACE An assembly intended to attach the system piping to the building structure to resist earthquake loads in two directions commonly consisting of: a) A sway brace tting; b) A brace member; and c) A structure att

29、achment tting. Examples of sway brace devices are shown in Appendix A. JUNE 27, 2016 SWAY BRACE DEVICES FOR SPRINKLER SYSTEM PIPING - UL 203A 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 5.11 STRUCTURE ADAPTER A device to facilitate the

30、attachment of a sway brace to a specic building structural member. 5.12 STRUCTURE ATTACHMENT FITTING A device used to attach a sway brace directly to the building structure. 5.13 SWAY BRACE FITTING A device used to attach the brace member of the sway brace to the system piping. 5.14 SWAY BRACE FITTI

31、NG ADAPTER A device to transition the attachment of the sway brace tting to the sway brace member. 5.15 SWAY BRACE, LATERAL A sway brace intended to resist differential movement perpendicular to the axis of the system piping. See Figure 5.1 as an example. This is generated text for gtxt. 5.16 SWAY B

32、RACE, LONGITUDINAL A sway brace intended to resist differential movement parallel to the axis of the system piping. See Figure 5.2 as an example. This is generated text for gtxt. Figure 5.1 Lateral sway brace (End view) DECEMBER 18, 2015 SWAY BRACE DEVICES FOR SPRINKLER SYSTEM PIPING - UL 203A 6UL C

33、OPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 5.17 SWAY BRACE, NON-RIGID A sway brace intended for resisting loads in tension only. See Figure A.3 as an example 5.18 SWAY BRACE, RIGID A sway brace intended for resisting both tension and compre

34、ssion loads. CONSTRUCTION 6 General 6.1 A sway brace assembly shall be constructed for connection to the system piping and be able to withstand the appropriate test load specied in the Load Test, Section 9, for the corresponding pipe size. 6.2 A sway brace tting shall be designed to directly attach

35、to the system piping. 6.3 A brace member of a rigid sway brace shall be such that the maximum slenderness ratio l/r, where l is the length of the brace and r is the least radius of gyration, does not exceed that specied in the Standard for the Installation of Sprinkler Systems, NFPA 13. 6.4 The manu

36、facturer of rigid type sway brace components and devices, ttings or structure attachment ttings are not required to supply the brace member. If the brace member is not provided, the manufacturers installation instructions shall indicate the appropriate sway brace member conguration, material and siz

37、e. Figure 5.2 Longitudinal sway brace (Side view) DECEMBER 18, 2015 SWAY BRACE DEVICES FOR SPRINKLER SYSTEM PIPING - UL 203A 7UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 6.5 A structure attachment tting or fastener adapter shall be const

38、ructed to use fasteners to secure the tting to the building structure. When fasteners are provided with a structure attachment tting, they shall be capable of withstanding the required test loads specied in Load Test, Section 9. 6.6 A structure attachment tting or fastener adapter shall be construct

39、ed with the number of fastener holes and hole diameter sizes to accommodate the loads specied in the Standard for the Installation of Sprinkler Systems, NFPA 13. 6.7 A structure attachment tting or fastener adapter shall be constructed with the hole diameter(s) not exceeding 1/16 in. larger than the

40、 intended fastener diameter. 6.8 A lateral sway brace component shall not be used as a part of longitudinal sway brace assemblies unless investigated for such use. Likewise, a longitudinal sway brace component shall not be used as part of lateral sway brace assemblies unless investigated for such us

41、e. 6.9 A Non-Rigid Sway Brace (Tension Only) using cable as the brace member shall consist of an assembly of cable and necessary hardware to secure the cable to structure attachment tting or system pipe. 6.10 Galvanized carbon steel cable used in Non-Rigid Sway Braces (Tension Only) shall comply wit

42、h the requirements of the Standard Specication for Stranded Carbon Steel Wire Ropes for General Purposes, ASTM A1023/A1023M, Table 7 for 7x7 and 7x19 small diameter specialty cord or equivalent. Stainless steel cable may also be used provided that it meets the requirements of the Standard Specicatio

43、n for Stainless Steel Wire Strand, ASTM A368 or the Standard Specication for Stainless Steel Rope Wire, ASTM A492 (as specied in Standard for the Installation of Sprinkler Systems, NFPA 13 and Standard Guidelines for the Structural Applications of Steel Cables for Buildings, ASCE 19). 6.11 A restrai

44、nt device shall be constructed for sprinkler branch line piping of 2 NPS and smaller. 7 Materials 7.1 Components of sway brace assemblies shall be made of ferrous materials. Exception: Nonferrous materials, such as plastics and zinc alloys, shall be permitted to be used when they have been investiga

45、ted to verify resistance to external re exposure, and loss of strength with aging and environmental exposure. JUNE 27, 2016 SWAY BRACE DEVICES FOR SPRINKLER SYSTEM PIPING - UL 203A 8UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 8 Protectiv

46、e Coatings 8.1 A sway brace tting or structural attachment tting or part of a tting made of at iron or steel, the thickness of the metal shall be at least #7 gauge (nominal 0.1793 inch), unless protected by coating as described in 8.2. 8.2 When protective coatings are used in accordance with 8.1, th

47、e following coatings meet the intent of this requirement: a) A zinc coating having a minimum thickness of 0.0005 inch (0.0127 mm) on all outside surfaces and 0.0003 inch (0.0076 mm) on all inside surfaces. The thickness of the coating is to be established by the Metallic Coating Thickness Test, Sect

48、ion 11. b) A hot-dipped mill galvanized sheet steel conforming with the coating designation G90 in Table I of the Standard Specication for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process, ASTM A653/A653M, with not less than 40 percent of the zinc

49、 on any side, based on the minimum single spot test requirement in this ASTM Designation. The weight of the zinc coating is to be determined by any equivalent method; however, in case of question, the weight of the coating shall be established in accordance with the test method of the Standard Test Method for Weight (Mass) of Coating or Iron or Steel Articles with Zinc or Zinc-Alloy Coatings, ASTM A90/A90M. The edges of a stamping complying with this requi

展开阅读全文
相关资源
  • ANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdfANSI Z97 1-2009 American National Standard for Safety Glazing Materials used in Buildings - Safety Performance Specifications and Methods of Test《建筑物中窗用玻璃材料安全性用.pdf
  • ANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdfANSI Z97 1 ERTA-2010 Re ANSI Z97 1 - 2009 Errata《修订版 美国国家标准学会Z97 1-2009标准的勘误表》.pdf
  • ANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdfANSI Z21 40 2a-1997 Gas-Fired Work Activated Air-Conditioning and Heat Pump Appliances (Same as CGA 2 92a)《燃气、工作激活空气调节和热泵器具(同 CGA 2 92a)》.pdf
  • ANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdfANSI Z124 9-2004 American National Standard for Plastic Urinal Fixtures《塑料小便器用美国国家标准》.pdf
  • ANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdfANSI Z124 4-2006 American National Standard for Plastic Water Closet Bowls and Tanks《塑料抽水马桶和水箱用美国国家标准》.pdf
  • ANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdfANSI Z124 3-2005 American National Standard for Plastic Lavatories《塑料洗脸盆用美国国家标准》.pdf
  • ANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdfANSI T1 659-1996 Telecommunications - Mobility Management Application Protocol (MMAP) RCF-RACF Operations《电信 可移动管理应用协议(MMAP) RCF-RACF操作》.pdf
  • ANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdfANSI T1 651-1996 Telecommunications – Mobility Management Application Protocol (MMAP)《电信 可移动性管理应用协议》.pdf
  • ANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdfANSI T1 609-1999 Interworking between the ISDN User-Network Interface Protocol and the Signalling System Number 7 ISDN User Part《电信 ISDN用户间网络接口协议和7号信令系统ISDN用户部分.pdf
  • ANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdfANSI T1 605-1991 Integrated Services Digital Network (ISDN) - Basic Access Interface for S and T Reference Points (Layer 1 Specification)《综合服务数字网络(ISDN) S和T基准点的.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ANSI

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1