1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 486G Sealed Twist-On Connecting Devices STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL N
2、OT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Sealed Twist-On Connecting Devices, UL 486G First Edition, Dated January 26, 2018 Summary of Topics This is the First Edition of the Standard for Safety for Sealed Twist-On Connecting Devices
3、, UL 486G, and reects the rst time ANSI approval of the new document. The new requirements are substantially in accordance with Proposal(s) on this subject dated July 21, 2017. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any for
4、m by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In
5、 no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advis
6、ed of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any l
7、oss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. JANUARY 26, 2018 UL 486G tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTH
8、ER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JANUARY 26, 2018 UL 486G tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Association of Standardization and Certication NMX-J-745-ANCE-2018 First Edition CSA
9、Group CSA C22.2 No. 355-18 First Edition Underwriters Laboratories Inc. UL 486G First Edition Sealed Twist-On Connecting Devices January 26, 2018 ANSI/UL 486G-2018UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Commitment for Amendments This
10、 standard is issued jointly by the Association of Standardization and Certication (ANCE), the Canadian Standards Association (operating as “CSA Group”), and Underwriters Laboratories Inc. (UL). Comments or proposals for revisions on any part of the standard may be submitted to ANCE, CSA Group, or UL
11、 at anytime. Revisions to this standard will be made only after processing according to the standards development procedures of ANCE, CSA Group, and UL. CSA Group and UL will issue revisions to this standard by means of a new edition or revised or additional pages bearing their date of issue. ANCE w
12、ill incorporate the same revisions into a new edition of the standard bearing the same date of issue as the CSA Group and UL pages. Copyright 2018 ANCE Rights reserved in favor of ANCE. ISBN 978-1-4883-1163-5 2018 CSA Group All rights reserved. No part of this publication may be reproduced in any fo
13、rm whatsoever without the prior permission of the publisher. This Standard is subject to review within ve years from the date of publication, and suggestions for its improvement will be referred to the appropriate committee. To submit a proposal for change, please send the following information to i
14、nquirescsagroup.org and include Proposal for change in the subject line: Standard designation (number); relevant clause, table, and/or gure number; wording of the proposed change; and rationale for the change. To purchase CSA Group Standards and related publications, visit CSA Groups Online Store at
15、 shop.csa.ca or call toll-free 1-800-463-6727 or 416-747-4044. Copyright 2018 Underwriters Laboratories Inc. To purchase UL Standards, visit COMM 2000 at http:/m- or call toll free 18888533503. This ANSI/UL Standard for Safety consists of the First Edition. The most recent designation of ANSI/UL 486
16、G as an American National Standard (ANSI) occurred on January 26, 2018. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, Title Page (front and back), or the Preface. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Pr
17、oposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at https:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, o
18、wnerships, and rights regarding those Standards shall remain the sole and exclusive property of UL.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS PREFACE 4 1 Scope .5 2 Reference Publications 5 2.1 Undated and dated references .5 2
19、.2 Normative references .6 3 Units of Measurement .7 4 Denitions7 5 Symbols and Abbreviations 7 6 Construction8 6.1 Wire connectors 8 6.2 Insulation 8 7 Test Requirements 8 7.1 General .8 7.2 Test sequence .9 7.3 Flex conditioning .9 7.4 Immersion .9 7.5 Heat conditioning .9 7.6 Cold conditioning .9
20、 7.7 Repeated immersion 9 7.8 Insulation resistance 9 7.9 Dielectric withstand .9 7.10 Leakage current .9 8 Sampling Requirements .9 8.1 General .9 9 Test Methods10 9.1 General 10 9.2 Test sequence 12 9.3 Flex conditioning 12 9.4 Immersion 12 9.5 Heat conditioning 12 9.6 Cold conditioning 12 9.7 Rep
21、eated immersion .12 9.8 Insulation resistance .13 9.9 Dielectric withstand 13 9.10 Leakage current13 10 Marking, Labeling, and Packaging 13 Annex A Guarded Circuit A.1 Description 14 A.2 Setup.14 A.3 Guarded Circuit 14 JANUARY 26, 2018 NMX-J-745-ANCE-2018 CSA C22.2 NO. 355-18 UL 486G 3UL COPYRIGHTED
22、 MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL PREFACE This is the harmonized ANCE, CSA Group, and UL standard for Sealed Twist-On Connecting Devices. It is the rst edition of NMX-J-745-ANCE, the rst edition of CSA C22.2 No. 355, and the rst edition of U
23、L 486G. This harmonized standard was prepared by the Association of Standardization and Certication, (ANCE), CSA Group and Underwriters Laboratories Inc. (UL). The efforts and support of the Technical Harmonization Committee, CANENA Technical Harmonization Committee 99 Electrical Connectors on the H
24、armonization of Electrotechnical Standards of the Nations of the Americas (CANENA), are gratefully acknowledged. are gratefully appreciated. This standard is considered suitable for use for conformity assessment within the stated scope of the standard. This standard was reviewed by the CSA Subcommit
25、tee on Wiring Devices for Household and General Use, under the jurisdiction of the CSA Technical Committee on Industrial Products and the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the CSA Technical Committee. This standard has been deve
26、loped in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. This standard has been approved by the American National Standards Institute (ANSI) as an American National Standard. Application o
27、f Standard Where reference is made to a specic number of samples to be tested, the specied number is to be considered a minimum quantity. Note: Although the intended primary application of this standard is stated in its scope, it is important to note that it remains the responsibility of the users o
28、f the standard to judge its suitability for their particular purpose. Level of Harmonization This standard is published as an identical standard for ANCE, CSA Group, and UL. An identical standard is a standard that is exactly the same in technical content except for national differences resulting fr
29、om conicts in codes and governmental regulations. Presentation is word for word except for editorial changes. Interpretations The interpretation by the standards development organization of an identical or equivalent standard is based on the literal text to determine compliance with the standard in
30、accordance with the procedural rules of the standards development organization. If more than one interpretation of the literal text has been identied, a revision is to be proposed as soon as possible to each of the standards development organizations to more accurately reect the intent. JANUARY 26,
31、2018 NMX-J-745-ANCE-2018 CSA C22.2 NO. 355-18 UL 486G 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Fuseholders Part 12: Class R 1 Scope 1.1 The wire connectors covered by these requirements are intended for use with copper conductor in a
32、ccordance with installations covered by the National Electrical Code, NFPA 70; the Canadian Electrical Code, Part I, C22.1; and NOM 001 SEDE, Standard for Electrical Installations. The requirements in this standard cover twist-on style splicing sealed wire connectors intended for installations for a
33、pplications noted below: a) In accordance with wiring methods where the connector is installed in enclosures rated for the environment and located in dry locations, damp locations, wet locations, below grade, or above grade. b) In lighting systems operating at 30 volts or less (rated 25 amperes and
34、30 volts, 42.4 volts peak, maximum), and lighting equipment connected to a Class 2 power source; where the connector is located in dry locations, damp locations, wet locations, direct buried locations, below grade, or above grade where protected from direct exposure to sunlight. NOTE: Sealed wire co
35、nnectors used in these applications do not require the use of an enclosure. c) In Canada, Class 2 circuits located in dry locations, damp locations, wet locations, direct buried locations, below grade, or above grade where protected from direct exposure to sunlight. In the United States and Mexico,
36、Class 2 and Class 3 circuits located in dry locations, damp locations, wet locations, direct buried locations, below grade, or above grade where protected from direct exposure to sunlight. NOTE: Sealed wire connectors used in these applications do not require the use of an enclosure. 1.2 Splicing se
37、aled wire connectors covered by this standard are intended for use with single or multiple conductor underground feeder cable, golf course sprinkler cable, underground low energy cable, irrigation cable, or other cable with insulation acceptable for direct burial, below grade use, or wet locations.
38、1.3 Splicing sealed wire connectors covered by this standard are intended for use with copper conductor sizes 30 AWG (0.05 mm 2 ) through 6 AWG (13.3 mm 2 ) with currents not exceeding the ampacity of insulated conductors rated either 75 C (167 F) or 90 C (194 F) and intended for use at 600 V or les
39、s. 1.4 For products intended for use in Canada, general requirements are given in CAN/CSA-C22.2 No. 0. 2 Reference Publications 2.1 Undated and dated references 2.1.1 For undated references to standards, such reference shall be considered to refer to the latest edition and all revisions to that edit
40、ion up to the time when this standard was approved. For dated references to standards, such reference shall be considered to refer to the dated edition and all revisions published to that edition up to the time this standard was approved. JANUARY 26, 2018 NMX-J-745-ANCE-2018 CSA C22.2 NO. 355-18 UL
41、486G 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 2.2 Normative references Where reference is made to any Standards, such reference shall be considered to refer to the latest editions and revisions thereto available at the time of printi
42、ng, unless otherwise specied. 2.2.1 ANCE Standards NMX-J-548-ANCE, Splicing Wire Connectors 2.2.2 CSA Standards C22.1-15 Canadian Electrical Code, Part I (CE Code) CAN/CSA-C22.2 No. 0-10 (R2015), General-requirements Canadian Electrical Code, Part II C22.2 No. 188-13, Splicing Wire Connectors 2.2.3
43、UL Standards UL 486C Splicing Wire Connectors 2.2.4 ASTM Standards ANSI/ASTM G21-15, Standard Practice for Determining Resistance of Synthetic Polymeric Materials to Fungi 2.2.5 NFPA* Standard ANSI/NFPA 70-2017, National Electrical Code (NEC) *National Fire Protection Association JANUARY 26, 2018 NM
44、X-J-745-ANCE-2018 CSA C22.2 NO. 355-18 UL 486G 6UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 2.2.6 NOM Standards Mexican Secretary of Energy NOM-001-SEDE, Standard for Electrical Installations 3 Units of Measurement 3.1 The dimensional va
45、lues given in SI (metric) units shall be normative. Any other values provided in parenthesis are for information purposes only. 3.2 Conductor sizes expressed in AWG/kcmil units shall be normative. Conductor sizes expressed in mm 2 are for information only and represent a soft conversion of AWG/kcmil
46、 wire sizes. These wire sizes in mm 2 do not typically exist. Note: 4 AWG (21.2 mm 2 ) A typical commercially available wire size would be 25 mm 2 , not 21.2 mm 2 . 4 Denitions 4.1 For the purpose of this Standard, the following terms and denitions apply. 4.2 SEALED WIRE CONNECTOR a connector and it
47、s integral insulating and sealing components. 5 Symbols and Abbreviations 5.1 Degree 5.2 A Amps, Amperes 5.3 AWG American Wire Gage 5.4 C Celsius 5.5 Cu Copper 5.6 h Hour 5.7 Hz Hertz, cycles per second 5.8 in Inches 5.9 kcmil Thousand circular mils 5.10 m Meter 5.11 min Minutes JANUARY 26, 2018 NMX
48、-J-745-ANCE-2018 CSA C22.2 NO. 355-18 UL 486G 7UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 5.12 mL Milliliter 5.13 mm Millimeter 5.14 mm 2 Square millimeter 5.15 sol Solid 5.16 str Stranded 5.17 V Volts 6 Construction 6.1 Wire connectors
49、 6.1.1 Wire connectors shall comply with UL 486C, CSA C22.2 No. 188, or NMX-J-548-ANCE, as applicable. 6.2 Insulation 6.2.1 Material used in the outer cover to insulate a sealed wire connector system shall be resistant to fungi attack. Materials not known to be resistant to fungi shall comply with Level 0 or 1. A natural, organic ber such as cotton, paper, jute, or hemp shall not be used. Materials k