ARMY A-A-59326 14 B-2011 REDUCER EXTERNAL PIPE THREAD BY FEMALE TYPE XIII.pdf

上传人:boatfragile160 文档编号:440332 上传时间:2018-11-15 格式:PDF 页数:3 大小:82.76KB
下载 相关 举报
ARMY A-A-59326 14 B-2011 REDUCER EXTERNAL PIPE THREAD BY FEMALE TYPE XIII.pdf_第1页
第1页 / 共3页
ARMY A-A-59326 14 B-2011 REDUCER EXTERNAL PIPE THREAD BY FEMALE TYPE XIII.pdf_第2页
第2页 / 共3页
ARMY A-A-59326 14 B-2011 REDUCER EXTERNAL PIPE THREAD BY FEMALE TYPE XIII.pdf_第3页
第3页 / 共3页
亲,该文档总共3页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 Beneficial comments, recommendations, additions, deletions, clarifications, etc. and any data that may improve this document should be sent to DAMI_STANDARDIZATIONconus.army.mil or U.S. Army RDECOM, Tank Automotive Research, Development and Engineering Center, ATTN: RDTA-EN/STND/TRANS MS #268, 6501

2、 E. 11 Mile Road, Warren, MI 48397-5000. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at https:/assist.daps.dla.mil. AMSC N/A FSC 4730 Distribution Statement A. Approved for public release; distribution is unli

3、mited. INCH-POUND A-A-59326/14B April 21, 2011 SUPERSEDING A-A-59326/14A May 1, 2003 COMMERCIAL ITEM DESCRIPTION SPECIFICATION SHEET REDUCER, EXTERNAL PIPE THREAD BY FEMALE, TYPE XIII The General Services Administration has authorized the use of this commercial item description for all federal agenc

4、ies. The complete requirements for procuring couplings described herein shall consist of this document and the latest issue in effect of A-A-59326. 1. SCOPE. This specification sheet covers an External Pipe Thread by Female Cam-locking type Reducer, Type XIII, to be used in conjunction with fittings

5、 having an internal pipe thread and/or male type cam locking coupling halves. 2. CLASSIFICATION. The size of the reducers if designated in table I. TABLE I. Reducer size. Dash Number Threaded End Size - TPI Cam-lock End Nom. Size Gasket Size code 1 4 - 8 3 -8 2 3 - 8 2 -6 3 2 - 11 1 -3 4 6 - 8 4 -9

6、5 1 - 11 2 -6 6 2 - 11 1 -5 7 1 - 11 3 -8 8 1 - 11 1 -5 9 1 - 11 2 -6 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59326/14B 2 3. SALIENT CHARACTERISTICS. The following characteristics may differ from those listed in the latest issue of A-A-59

7、326. 3.1 Accessories. The coupling shall be supplied with pull rings and gasket. 3.2 Threads. The coupling threads shall conform to National Tapered Pipe Thread per ANSI/ASME B1.20.1. 3.3 Hydrostatic test pressure. The 1-inch through 4-inch couplings shall withstand a hydrostatic test pressure of 30

8、0 pounds per square inch gage (psig). The 6-inch, 75 psi rated couplings shall withstand a hydrostatic test pressure of 150 psig. The 6-inch, 150 psi rated couplings shall withstand a minimum hydrostatic test pressure of 225 psig. 3.4 Working pressure. The -inch through 4-inch couplings shall be rat

9、ed for 150 pounds per square inch working pressure. The 6-inch couplings shall be rated for 75 psi or 150 psi working pressure as appropriate. .50 MIN CA M - LO CK INT E RF A CE ( S E E A - A - 59326 ) T HREA DE D INT E RF A CE ( S E E T A B LE ) P ULL RING ( S E E A - A - 59326 ) FIGURE 1. Reducer,

10、 external pipe thread by female. NOTES: 1. The size of the coupling assembly shall conform to table I. 2. Dimensions are in inches. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59326/14B 3 4. NOTES 4.1 Part Identification Number (PIN). The fol

11、lowing PIN procedure is for government purposes and does not constitute a requirement for the contractor. This example describes a part numbering system for specification sheet A-A-59326/14 AA59326/14-4-A-1; where /14 indicates a External Pipe Thread by Female cam-lock Reducer, -4 indicates a 6-inch

12、 threaded end by 4 inch cam locking end, -A indicates an Aluminum body and -1 indicates a style 1 coupling. Material: A - Aluminum Alloy B - Copper Alloy (Brass or Bronze) BA - Aluminum Bronze SS - Stainless Steel Style 1 - Style 1 couplings do not require the incorporation of a positive locking mec

13、hanism to lock the cam arms in the closed position but the cam arms shall stay in the closed position when the coupling halves are assembled. Style 2 - Style 2 couplings shall incorporate a positive locking mechanism to lock the cam arms in the closed position when the coupling halves are assembled.

14、 The locking mechanism shall be manually released (the release doesnt have to stay in the released position) before the cam arms can be moved to the open position. MILITARY INTERESTS: CIVIL AGENCY COORDINATING ACTIVITY: GSA - FAS Custodians: Army - AT Preparing Activity: Navy - YD Army - AT Air Forc

15、e - 99 (Project 4730-2011-026) Review Activities: Army - AV, GL Navy - MC, SH Air Force - 71 DLA CC NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • API TR 402-1995 Tertiary-Amyl Methyl Ether (TAME) Toxicity to the Freshwater Alga Selenastrum Capricornutum《三戊甲基醚对淡水羊角月芽藻的毒性》.pdf API TR 402-1995 Tertiary-Amyl Methyl Ether (TAME) Toxicity to the Freshwater Alga Selenastrum Capricornutum《三戊甲基醚对淡水羊角月芽藻的毒性》.pdf
  • API TR 403-1995 Closed-Patch Repeated Insult Dermal Sensitization Study of Tertiary Amyl Methyl Ether (TAME) in Guinea Pigs (Buehler Method)《三戊甲基醚对几内亚猪皮下注射敏感反应的研究(标乐方法)》.pdf API TR 403-1995 Closed-Patch Repeated Insult Dermal Sensitization Study of Tertiary Amyl Methyl Ether (TAME) in Guinea Pigs (Buehler Method)《三戊甲基醚对几内亚猪皮下注射敏感反应的研究(标乐方法)》.pdf
  • API TR 404-1995 Inhalation Oncogenicity Study of Commercial Hexane in Rats and Mice Part I - Rats Final Abridged Report《鼠吸入工业已烷致瘤性研究-第1部分 关于大鼠最后的简略报告》.pdf API TR 404-1995 Inhalation Oncogenicity Study of Commercial Hexane in Rats and Mice Part I - Rats Final Abridged Report《鼠吸入工业已烷致瘤性研究-第1部分 关于大鼠最后的简略报告》.pdf
  • API TR 405-1995 Inhalation Oncogenicity Study of Commercial Hexane in Rats and Mice Part II - Mice Final Abridged Report《吸入致瘤性研究-第1部分 关于小鼠最后的简略报告》.pdf API TR 405-1995 Inhalation Oncogenicity Study of Commercial Hexane in Rats and Mice Part II - Mice Final Abridged Report《吸入致瘤性研究-第1部分 关于小鼠最后的简略报告》.pdf
  • API TR 406-1995 Tert-Amyl Methyl Ether (TAME) - Acute Toxicity to Daphnids (Daphnia Magna) Under Flow- Through Conditions TSCA Guideline Section Mark 797.1300《在流水环境中三戊甲基醚对大型溞急性毒性 T.pdf API TR 406-1995 Tert-Amyl Methyl Ether (TAME) - Acute Toxicity to Daphnids (Daphnia Magna) Under Flow- Through Conditions TSCA Guideline Section Mark 797.1300《在流水环境中三戊甲基醚对大型溞急性毒性 T.pdf
  • API TR 406-1995 Tert-Amyl Methyl Ether (TAME) - Acute Toxicity to Daphnids (Daphnia Magna) Under Flow- Through Conditions TSCA Guideline Section Mark 797.1300《在流水环境中三戊甲基醚对大型溞急性毒性 T_1.pdf API TR 406-1995 Tert-Amyl Methyl Ether (TAME) - Acute Toxicity to Daphnids (Daphnia Magna) Under Flow- Through Conditions TSCA Guideline Section Mark 797.1300《在流水环境中三戊甲基醚对大型溞急性毒性 T_1.pdf
  • API TR 407-1995 Tert-Amyl Methyl Ether (TAME) - Acute Toxicity to Mysid Shrimp (Mysidopsis Bahia) Under Static Renewal Conditions TSCA Guideline Section Mark 797.1930《更换的静水三戊甲基醚对糠虾.pdf API TR 407-1995 Tert-Amyl Methyl Ether (TAME) - Acute Toxicity to Mysid Shrimp (Mysidopsis Bahia) Under Static Renewal Conditions TSCA Guideline Section Mark 797.1930《更换的静水三戊甲基醚对糠虾.pdf
  • API TR 407-1995 Tert-Amyl Methyl Ether (TAME) - Acute Toxicity to Mysid Shrimp (Mysidopsis Bahia) Under Static Renewal Conditions TSCA Guideline Section Mark 797.1930《更换的静水三戊甲基醚对糠虾_1.pdf API TR 407-1995 Tert-Amyl Methyl Ether (TAME) - Acute Toxicity to Mysid Shrimp (Mysidopsis Bahia) Under Static Renewal Conditions TSCA Guideline Section Mark 797.1930《更换的静水三戊甲基醚对糠虾_1.pdf
  • API TR 408-1995 Tert-Amyl Methyl Ether (TAME) - Acute Toxicity to Rainbow Trout (Oncorhynchus Mykiss) Under Flow-Through Conditions TSCA Guideline Section Mark 797.1400《在流水环境下三戊甲基醚.pdf API TR 408-1995 Tert-Amyl Methyl Ether (TAME) - Acute Toxicity to Rainbow Trout (Oncorhynchus Mykiss) Under Flow-Through Conditions TSCA Guideline Section Mark 797.1400《在流水环境下三戊甲基醚.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ARMY

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1