资源描述

1、6.1CHAPTER 6PANEL HEATING AND COOLINGPRINCIPLES OF THERMAL RADIATION. 6.1General Evaluation 6.1Heat Transfer by Panel Surfaces 6.2General Design Considerations. 6.6Panel Design 6.8HEATING AND COOLING PANEL SYSTEMS 6.9Hydronic Panel Systems . 6.10Hydronic Metal Ceiling Panels 6.13Distribution and Lay

2、out . 6.14Electrically Heated Panel Systems. 6.16Air-Heated or Air-Cooled Panels. 6.18Controls 6.19Hybrid (Load-Sharing) HVAC Systems 6.20ANEL heating and cooling systems use temperature-controlledPindoor surfaces on the floor, walls, or ceiling; temperature ismaintained by circulating water, air, o

3、r electric current through acircuit embedded in or attached to the panel. A temperature-controlled surface is called a radiant panel if 50% or more of thedesign heat transfer on the temperature-controlled surface takesplace by thermal radiation. Panel systems are characterized by con-trolled surface

4、 temperatures below 150C. Panel systems may becombined either with a central forced-air system of one-zone,constant-temperature, constant-volume design, or with dual-duct,reheat, multizone or variable-volume systems, decentralized con-vective systems, or in-space fan-coil units. These combined sys-t

5、ems are called hybrid (load-sharing) HVAC systems.This chapter covers temperature-controlled surfaces that are theprimary source of sensible heating and cooling in the conditionedspace. For snow-melting and freeze-protection applications, seeChapter 51 of the 2011 ASHRAE HandbookHVAC Applications.Ch

6、apter 16 covers high-temperature panels over 150C, which maybe energized by gas, electricity, or high-temperature water.PRINCIPLES OF THERMAL RADIATIONThermal radiation (1) is transmitted at the speed of light, (2) trav-els in straight lines and can be reflected, (3) elevates the temperatureof solid

7、 objects by absorption but does not noticeably heat the airthrough which it travels, and (4) is exchanged continuously betweenall bodies in a building environment. The rate at which thermal radi-ation occurs depends on the following factors:Temperature of the emitting surface and receiverEmittance o

8、f the radiating surfaceReflectance, absorptance, and transmittance of the receiverView factor between the emitting and receiver surfaces (viewingangle of the occupant to the thermal radiation source)ASHRAE research project RP-876 (Lindstrom et al. 1998) con-cluded that surface roughness and texture

9、have insignificant effectson thermal convection and thermal radiation, respectively. Surfaceemittance (the ratio of the radiant heat flux emitted by a body to thatemitted by a blackbody under the same conditions) for typicalindoor surfaces, such as carpets, vinyl texture paint, and plastic,remained

10、between 0.9 and 1.0 for panel surface temperatures of30 to 55C.The structure of the radiation surface is critical. In general, roughsurfaces have low reflectance and high emittance/absorptancecharacteristics. Conversely, smooth or polished metal surfaces havehigh reflectance and low absorptance/emit

11、tance.One example of heating by thermal radiation is the feeling ofwarmth when standing in the suns rays on a cool, sunny day. Some ofthe rays come directly from the sun and include the entire electro-magnetic spectrum. Other rays are absorbed by or reflected fromsurrounding objects. This generates

12、secondary rays that are a combi-nation of the wavelength produced by the temperature of the objectsand the wavelength of the reflected rays. If a cloud passes in front ofthe sun, there is an instant sensation of cold. This sensation is causedby the decrease in the amount of heat received from solar

13、radiation,although there is little, if any, change in the ambient air temperature.Thermal comfort, as defined in ASHRAE Standard 55, is “thatcondition of mind which expresses satisfaction with the thermalenvironment.” No system is completely satisfactory unless the threemain factors controlling heat

14、 transfer from the human body (radia-tion, convection, and evaporation) result in thermal neutrality.Maintaining correct conditions for human thermal comfort by ther-mal radiation is possible for even the most severe climatic condi-tions (Buckley 1989). Chapter 9 of the 2009 ASHRAE HandbookFundament

15、als has more information on thermal comfort.Panel heating and cooling systems provide an acceptable thermalenvironment by controlling surface temperatures as well as indoorair temperature in an occupied space. With a properly designed sys-tem, occupants should not be aware that the environment is be

16、ingheated or cooled. The mean radiant temperature (MRT) has astrong influence on human thermal comfort. When the temperatureof surfaces comprising the building (particularly outdoor exposedwalls with extensive fenestration) deviates excessively from theambient temperature, convective systems sometim

17、es have difficultycounteracting the discomfort caused by cold or hot surfaces. Heat-ing and cooling panels neutralize these deficiencies and minimizeradiation losses or gains by the human body.Most building materials have relatively high surface emittanceand, therefore, absorb and reradiate heat fro

18、m active panels. Warmceiling panels are effective because heat is absorbed and reflectedby the irradiated surfaces and not transmitted through the construc-tion. Glass is opaque to the wavelengths emitted by active panelsand, therefore, transmits little long-wave thermal radiation outside.This is si

19、gnificant because all surfaces in the conditioned space tendto assume temperatures that result in an acceptable thermal comfortcondition.GENERAL EVALUATIONPrincipal advantages of panel systems are the following:Because not only indoor air temperature but also mean radianttemperature can be controlle

20、d, total human thermal comfort maybe better satisfied.Because the operative temperature for required human thermalcomfort may be maintained by primarily controlling the meanradiant temperature of the conditioned indoor space, dry-bulb airtemperature may be lower (in heating) or higher (in cooling),T

21、he preparation of this chapter is assigned to TC 6.5, Radiant Heating andCooling.6.2 2012 ASHRAE HandbookHVAC Systems and Equipment (SI)which reduces sensible heating or cooling loads (see Chapter 15for the definition and calculation of operative and mean radianttemperatures).Hydronic panel systems

22、may be connected in series, followingother hydronic heating or cooling systems (i.e., their return watermay be used), increasing exergetic efficiency.Comfort levels can be better than those of other space-conditioningsystems because thermal loads are satisfied directly and airmotion in the space cor

23、responds to required ventilation only.Waste and low-enthalpy energy sources and heat pumps may bedirectly coupled to panel systems without penalty on equipmentsizing and operation. Being able to select from a wide range ofmoderate operation temperatures ensures optimum design forminimum cost and max

24、imum thermal and exergetic efficiency.Seasonal thermal distribution efficiency in buildings may behigher than in other hydronic systems.In terms of simple payback period, ceiling cooling panels andchilled beams have the highest technical energy savings potential(DOE 2002).Part or all of the building

25、 structure may be thermally activated(Meierhans and Olesen 2002).Space-conditioning equipment is not required at outdoor exposedwalls, simplifying wall, floor, and structural systems.Almost all mechanical equipment may be centrally located, sim-plifying maintenance and operation.No space within the

26、conditioned space is required for mechanicalequipment. This feature is especially valuable in hospital patientrooms, offices, and other applications where space is at a premium,if maximum cleanliness is essential or legally required.Draperies and curtains can be installed at outdoor exposed wallswit

27、hout interfering with the space-conditioning system.When four-pipe systems are used, cooling and heating can besimultaneous, without central zoning or seasonal changeover.Supply air requirements usually do not exceed those required forventilation and humidity control.Reduced airflow requirements hel

28、p mitigate bioterrorism risk,especially in large buildings.Modular panels provide flexibility to meet changes in partitioning.A 100% outdoor air system may be installed with smaller penal-ties in refrigeration load because of reduced air quantities.A common central air system can serve both the inte

29、rior andperimeter zones.Wet-surface cooling coils are eliminated from the occupied space,reducing the potential for septic contamination.Modular panel systems can use the automatic sprinkler systempiping (see NFPA Standard 13, Section 3.6). The maximum watertemperature must not fuse the heads.Panel

30、heating and cooling with minimum supply air quantitiesprovide a draft-free environment.Noise associated with fan-coil or induction units is eliminated.Peak loads are reduced as a result of thermal energy storage in thepanel structure, as well as walls and partitions directly exposed topanels.Panels

31、can be combined with other space-conditioning systems todecouple several indoor requirements (e.g., humidity control,indoor air quality, air velocity) and optimally satisfy them withoutcompromises.In-floor heating creates inhospitable living conditions for housedust mites compared to other heating s

32、ystems (Sugawara et al.1996).Disadvantages include the following:Response time can be slow if controls and/or heating elements arenot selected or installed correctly.Improper selection of panel heating or cooling tube or electricalheating element spacing and/or incorrect sizing of heating/coolingsou

33、rce can cause nonuniform surface temperatures or insufficientsensible heating or cooling capacity.Panels can satisfy only sensible heating and cooling loads unlesshybrid panels are used see the section on Hybrid (Load-Sharing)HVAC Systems. In a stand-alone panel cooling system, dehu-midification and

34、 panel surface condensation may be of primeconcern. Unitary dehumidifiers should be used, or a latent air-handling system should be introduced to the indoor space.HEAT TRANSFER BY PANEL SURFACESSensible heating or cooling panels transfer heat throughtemperature-controlled (active) surface(s) to or f

35、rom an indoor spaceand its enclosure surfaces by thermal radiation and natural convection.Heat Transfer by Thermal RadiationThe basic equation for a multisurface enclosure with gray,diffuse isothermal surfaces is derived by radiosity formulationmethods (see Chapter 4 of the 2009 ASHRAE HandbookFunda

36、-mentals). This equation may be written asqr= Jp Jj(1)whereqr= net heat flux because of thermal radiation on active (heated or cooled) panel surface, W/m2Jp= total radiosity leaving or reaching panel surface, W/m2Jj= radiosity from or to another surface in room, W/m2Fpj= radiation angle factor betwe

37、en panel surface and another surface in room (dimensionless)n = number of surfaces in room other than panel(s)Equation (1) can be applied to simple and complex enclosureswith varying surface temperatures and emittances. The net heat fluxby thermal radiation at the panel surfaces can be determined by

38、solving the unknown Jjif the number of surfaces is small. Morecomplex enclosures require computer calculations.Radiation angle factors can be evaluated using Figure 15 inChapter 4 of the 2009 ASHRAE HandbookFundamentals. Fanger(1972) shows room-related angle factors; they may also be devel-oped from

39、 algorithms in ASHRAEs Energy Calculations I (1976).Several methods have been developed to simplify Equation (1)by reducing a multisurface enclosure to a two-surface approxima-tion. In the MRT method, the thermal radiation interchange in anindoor space is modeled by assuming that the surfaces radiat

40、e to afictitious, finite surface that has an emittance and surface tempera-ture that gives about the same heat flux as the real multisurface case(Walton 1980). In addition, angle factors do not need to be deter-mined in evaluating a two-surface enclosure. The MRT equationmay be written asqr= Fr (2)w

41、here = Stefan-Boltzmann constant = 5.67 108W/(m2K4)Fr= radiation exchange factor (dimensionless)Tp= effective temperature of heating (cooling) panel surface, KTr= temperature of fictitious surface (unheated or uncooled), KThe temperature of the fictitious surface is given by an area emit-tance weigh

42、ted average of all surfaces other than the panel(s):Tr= (3)whereAj= area of surfaces other than panels, m2j= thermal emittance of surfaces other than panel(s) (dimensionless)Fpjj=1nTp4Tr4AjjTjj=pnAjjj =pn-Panel Heating and Cooling 6.3When the surface emittances of an enclosure are nearly equal,and s

43、urfaces directly exposed to the panel are marginally unheated(uncooled), then Equation (3) becomes the area-weighted averageunheated (uncooled) temperature (AUST) of such surfaces exposedto the panels. Therefore, any unheated (uncooled) surface in thesame plane with the panel is not accounted for by

44、 AUST. For exam-ple, if only part of the floor is heated, the remainder of the floor isnot included in the calculation of AUST, unless it is observed byother panels in the ceiling or wall.The radiation interchange factor for two-surface radiation heatexchange is given by the Hottel equation:Fr= (4)w

45、hereFpr= radiation angle factor from panel to fictitious surface(1.0 for flat panel)Ap, Ar= area of panel surface and fictitious surface, respectivelyp, r= thermal emittance of panel surface and fictitious surface,respectively (dimensionless)In practice, the thermal emittance pof nonmetallic or pain

46、tedmetal nonreflecting surfaces is about 0.9. When this emittance is usedin Equation (4), the radiation exchange factor Fris about 0.87 formost indoor spaces. Substituting this value in Equation (2), Frbecomes 4.93 108. Min et al. (1956) showed that this constantwas 5.03 108in their test room. Then

47、the equation for heat fluxfrom thermal radiation for panel heating and cooling becomesapproximatelyqr= 5 108(tp+ 273.15)4 (AUST + 273.15)4(5)wheretp= effective panel surface temperature, CAUST = area-weighted temperature of all indoor surfaces of walls, ceiling,floor, windows, doors, etc. (excluding

48、 active panel surfaces), CEquation (5) establishes the general sign convention for thischapter, which states that heating by the panel is positive and cool-ing by the panel is negative.Radiation exchange calculated from Equation (5) is given inFigure 1. The values apply to ceiling, floor, or wall pa

49、nel output.Radiation removed by a cooling panel for a range of normallyencountered temperatures is given in Figure 2.In many specific instances where normal multistory commercialconstruction and fluorescent lighting are used, the indoor air tem-perature at the 1.5 m level closely approaches the AUST. In struc-tures where the main heat gain is through the walls or whereincandescent lighting is used, wall surface temperatures tend to riseconsiderably above the indoor air temperature.Heat Transfer by Natural ConvectionHeat flux f

展开阅读全文
相关资源
猜你喜欢
  • ASD-STAN PREN 3373-014-2007 Aerospace series Terminal lugs and in-line splices for crimping on electric conductors Part 014 In-line splices insulated and sealed for crimping on cop.pdf ASD-STAN PREN 3373-014-2007 Aerospace series Terminal lugs and in-line splices for crimping on electric conductors Part 014 In-line splices insulated and sealed for crimping on cop.pdf
  • ASD-STAN PREN 3375-001-2005 Aerospace series Cable electrical for digital data transmission Part 001 Technical specification (Edition P 1)《航空航天系列 数字数据传输用电缆 第001部分 技术规范 第P1版》.pdf ASD-STAN PREN 3375-001-2005 Aerospace series Cable electrical for digital data transmission Part 001 Technical specification (Edition P 1)《航空航天系列 数字数据传输用电缆 第001部分 技术规范 第P1版》.pdf
  • ASD-STAN PREN 3375-001-2016 Aerospace series Cable electrical for digital data transmission Part 001 Technical specification (Edition P 2).pdf ASD-STAN PREN 3375-001-2016 Aerospace series Cable electrical for digital data transmission Part 001 Technical specification (Edition P 2).pdf
  • ASD-STAN PREN 3375-002-2011 Aerospace series Cable electrical for digital data transmission Part 002 General (Edition P 2).pdf ASD-STAN PREN 3375-002-2011 Aerospace series Cable electrical for digital data transmission Part 002 General (Edition P 2).pdf
  • ASD-STAN PREN 3375-003-2006 Aerospace series Cable electrical for digital data transmission Part 003 Single braid C 77 Ohms C Type KG Product standard (Edition P 1)《航空航天系列 数字数据传输用电.pdf ASD-STAN PREN 3375-003-2006 Aerospace series Cable electrical for digital data transmission Part 003 Single braid C 77 Ohms C Type KG Product standard (Edition P 1)《航空航天系列 数字数据传输用电.pdf
  • ASD-STAN PREN 3375-004-2006 Aerospace series Cable electrical for digital data transmission Part 004 Double braid C 77 Ohms C Type WJ Product standard《航空航天系列 数字数据传输用电缆 第004部分 77欧的W.pdf ASD-STAN PREN 3375-004-2006 Aerospace series Cable electrical for digital data transmission Part 004 Double braid C 77 Ohms C Type WJ Product standard《航空航天系列 数字数据传输用电缆 第004部分 77欧的W.pdf
  • ASD-STAN PREN 3375-005-2006 Aerospace series Cable electrical for digital data transmission Part 005 Double braid + metallic layer C 77 Ohms C Type WV Product standard (Edition P1).pdf ASD-STAN PREN 3375-005-2006 Aerospace series Cable electrical for digital data transmission Part 005 Double braid + metallic layer C 77 Ohms C Type WV Product standard (Edition P1).pdf
  • ASD-STAN PREN 3375-006-2005 Aerospace series Cable electrical for digital data transmission Part 006 Single braid C 78 Ohms C Type XM Product standard (Edition P 1)《航空航天系列 数字数据传输用电.pdf ASD-STAN PREN 3375-006-2005 Aerospace series Cable electrical for digital data transmission Part 006 Single braid C 78 Ohms C Type XM Product standard (Edition P 1)《航空航天系列 数字数据传输用电.pdf
  • ASD-STAN PREN 3375-007-2015 Aerospace series Cable electrical for digital data transmission Part 007 Double braid C 77 ohms C Type WW Product standard (Edition P 2).pdf ASD-STAN PREN 3375-007-2015 Aerospace series Cable electrical for digital data transmission Part 007 Double braid C 77 ohms C Type WW Product standard (Edition P 2).pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1