ASTM C1309-1997(2012) Standard Practice for Performance Evaluation of In-Plant Walk-Through Metal Detectors 《内置穿过式金属探测器性能评估的标准操作规程》.pdf

上传人:boatfragile160 文档编号:464176 上传时间:2018-11-27 格式:PDF 页数:15 大小:224.75KB
下载 相关 举报
ASTM C1309-1997(2012) Standard Practice for Performance Evaluation of In-Plant Walk-Through Metal Detectors 《内置穿过式金属探测器性能评估的标准操作规程》.pdf_第1页
第1页 / 共15页
ASTM C1309-1997(2012) Standard Practice for Performance Evaluation of In-Plant Walk-Through Metal Detectors 《内置穿过式金属探测器性能评估的标准操作规程》.pdf_第2页
第2页 / 共15页
ASTM C1309-1997(2012) Standard Practice for Performance Evaluation of In-Plant Walk-Through Metal Detectors 《内置穿过式金属探测器性能评估的标准操作规程》.pdf_第3页
第3页 / 共15页
ASTM C1309-1997(2012) Standard Practice for Performance Evaluation of In-Plant Walk-Through Metal Detectors 《内置穿过式金属探测器性能评估的标准操作规程》.pdf_第4页
第4页 / 共15页
ASTM C1309-1997(2012) Standard Practice for Performance Evaluation of In-Plant Walk-Through Metal Detectors 《内置穿过式金属探测器性能评估的标准操作规程》.pdf_第5页
第5页 / 共15页
亲,该文档总共15页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: C1309 97 (Reapproved 2012)Standard Practice forPerformance Evaluation of In-Plant Walk-Through MetalDetectors1This standard is issued under the fixed designation C1309; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, t

2、he year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONNuclear regulatory authorities require personnel entering designated security areas to be screenedfor conce

3、aled weapons and personnel exiting areas containing specified quantities of special nuclearmaterial to be screened for metallic nuclear shielding materials. Portal-type walk-through metaldetectors are widely used to implement these requirements. This practice provides guidelines forevaluating the in

4、-plant performance of walk-through metal detectors.1. Scope1.1 This practice is one of several (see Appendix X1)developed to assist operators of nuclear facilities with meetingthe metal detection performance requirements set by regulatoryauthorities.1.2 This practice consists of four procedures usef

5、ul forevaluating the in-plant performance of walk-through metaldetectors (see Fig. 1).1.2.1 Two of the procedures provide data for evaluatingprobability of detection. These procedures use binomial data(alarm/not alarm).1.2.1.1 The detection sensitivity test (DST)2is the initialprocedure in the detec

6、tion probability evaluation series. It isused to establish the probability of detection immediately afterthe detector has been adjusted to its operational sensitivitysetting.1.2.1.2 The detection sensitivity verification test (DSVT)2procedure periodically provides data for evaluation of continu-ing

7、detection performance.1.2.2 The third procedure is a “functional test.” It is usedroutinely to verify that a metal detector is operating andresponds with the correct audio and visual signals whensubjected to a condition that should cause an alarm.1.2.3 The fourth procedure is used to verify that ala

8、rmsgenerated during detection sensitivity testing were likely theresult of the detection of metal and not caused by outsideinterferences or the perturbation of the detection field by thetesters body mass.1.2.3.1 This procedure also can be used to establish aprobability of occurrence for false alarms

9、, for example, 20 testpasses by a clean-tester resulting in no alarms indicates a falsealarm probability of less than 0.15 at 95 % confidence. Thisprocedure is optional unless required by the regulatory author-ity.1.3 This practice does not set test object specifications. Thespecifications should be

10、 issued by the regulatory authority.1.4 This practice is intended neither to set performancelevels nor to limit or constrain technologies.1.5 This practice does not address safety or operationalissues associated with the use of walk-through metal detectors.2. Referenced Documents2.1 ASTM Standards:3

11、C1238 Guide for Installation of Walk-Through Metal De-tectorsC1269 Practice for Adjusting the Operational SensitivitySetting of In-Plant Walk-Through Metal DetectorsC1270 Practice for Detection Sensitivity Mapping of In-Plant Walk-Through Metal DetectorsF1468 Practice for Evaluation of Metallic Weap

12、ons Detec-tors for Controlled Access Search and Screening1This practice is under the jurisdiction of ASTM Committee C26 on NuclearFuel Cycle and is the direct responsibility of Subcommittee C26.12 on SafeguardApplications.Current edition approved Jan. 1, 2012. Published January 2012. Originallyappro

13、ved in 1995. Last previous edition approved in 1997 as C1309 97(2003).DOI: 10.1520/C1309-97R12.2The DST is one of two procedures used to evaluate detection rate. TheDetection Sensitivity Verification Test (DSVT) is the other. In the evaluation teststrategy, the DST is used to initially determine and

14、 document the detection rate andthen the DSVT is used to periodically check that the detection rate continues to meetthe requirements.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume info

15、rmation, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 clean-tester, na person who does not carr

16、y anyextraneous metallic objects that would significantly alter thesignal produced when the person carries a test object.3.1.1.1 DiscussionBy example but not limitation, suchextraneous metallic objects may include: metallic belt buckles,metal buttons, cardiac pacemakers, coins, metal frame eye-glass

17、es, hearing aids, jewelry, keys, mechanical pens andpencils, shoes with metal shanks or arch supports, metallicsurgical implants, undergarment support metal, metal zippers,etc. In the absence of other criteria, a clean-tester passingthrough a metal detector shall not cause a disturbance signalgreate

18、r than 10 % of that produced when carrying the criticaltest object through the detector. Test objects requiring veryhigh sensitivity settings for detection require more completeelimination of extraneous metal to obtain less than 10 % signaldisturbance. The tester shall have a weight between 50104 kg

19、and a height between 1.441.93 m. Should a given detector besensitive to body size because of design or desired sensitivity,NOTE 1The number of detection sensitivity verification tests in a series, the number of passes per test, the acceptance criteria, and the frequency maybe established by regulato

20、ry authority or set by the security organization based on threat scenarios or vulnerability assessments; the numbers should besufficient to provide a degree of assurance commensurate with the detector application.NOTE 2If the detector fails to meet the acceptance criteria, the verification series is

21、 terminated. The detector then must be tested to reestablish theprobability of detection. If the probability of detection requirement cannot be met (repairs may be necessary), the detector must be mapped and theoperational sensitivity setting reestablished. Performance testing can then be resumed st

22、arting with a new detection sensitivity test.NOTE 3If the detector fails the functional test, the detector must be immediately removed from service (see Appendix X1).FIG. 1 Walk-Through Metal Detector Evaluation Testing ProgramC1309 97 (2012)2the physical size of testers should be smaller and within

23、 anarrower range. It is recommended that the clean-tester besurveyed with a high sensitivity hand-held metal detector toensure that no metal is present.3.1.2 critical orientation, nthe orthogonal orientation of atest object that produces the smallest detection signal orweakest detection anywhere in

24、the detection zone; the orthogo-nal orientation of a test object that requires a higher sensitivitysetting to be detected compared to the sensitivity settingsrequired to detect the object in all other orthogonal orienta-tions. See Fig. 2 for handgun orientations.3.1.2.1 DiscussionCritical orientatio

25、ns are determined bytesting using a mapping procedure such as described inPractice C1270 (see 3.1.21 and Fig. 3).3.1.2.2 DiscussionThe term critical orientation can beapplied in two ways. Critical orientation can refer to the worstcase orthogonal orientation in a single test path or the worstcase or

26、thogonal orientation for all the test paths (the entiredetection zone). The two are coincident in the critical test path.3.1.3 critical sensitivity setting, nthe lowest sensitivitysetting of a detector at which the critical test object in itscritical orientation is consistently detected (10 alarms o

27、ut of 10passages) when passed through the detection zone on thecritical test path.3.1.4 critical test element, nsee test element.3.1.5 critical test object, nthe one test object out of anygiven group of test objects that, in its critical orientation,produces the weakest detection signal anywhere in

28、the detec-tion zone.3.1.5.1 DiscussionThe group referred to consists of oneor more objects that are to be detected at the same detectorsetting.3.1.5.2 DiscussionDepending on the particular detector,some orientation-sensitive test objects may have differentcritical orientations through different test

29、 paths in the detectionzone. Hence, care must be taken in determining the critical testobject, its critical orientation, and the critical test path.3.1.6 critical test path, nthe straight-line shortest-coursepath through the portal aperture, as defined by an element onthe detection sensitivity map,

30、that produces the smallestdetection signal or weakest detection for a test object in itscritical orientation (see Fig. 4 and Fig. 2).3.1.7 detection sensitivity map (see Fig. 3 and AppendixX2), na depiction of the grid used to define test pathsthrough the detection zone, with each element of the gri

31、dcontaining a value, usually the sensitivity setting of thedetector, that is indicative of the detectability of the test object.3.1.7.1 DiscussionThese values are relative and describethe detection sensitivity pattern within the detection zone forthe specific test object. The values are derived by i

32、denticallytesting each defined test path using a specific test object in aFIG. 2 Six Standard Orthogonal Orientations for a HandgunNOTE 1Numbers are sensitivity setting values for a hypotheticaldetector. The numbers represent the lowest sensitivity setting at which theobject was detected ten out of

33、ten consecutive test passes through theindicated test path.FIG. 3 Example of Detection Sensitivity MapFIG. 4 3-D View of Detection Zones and Test GridC1309 97 (2012)3single orthogonal orientation. The value is usually the mini-mum sensitivity setting of the detector that will cause aconsistent alarm

34、 (10 out of 10 test passes when the test objectis passed through the detection field. Appendix X2 is a sampleform for a potential detection sensitivity map configuration.)3.1.8 detection sensitivity test, nsee 6.2.3.1.9 detection sensitivity verification test, nsee 6.3.3.1.10 detection zone, nthe vo

35、lume within the portalaperture.3.1.11 detector, nsee walk-through metal detector.3.1.12 element, nsee test element.3.1.13 event false alarm, nan alarm occurring when aclean-tester, while not carrying a test object, passes through thedetection zone of a detector operating at the operationalsensitivit

36、y setting.3.1.14 event false alarm test, nsee 6.4.3.1.15 functional test, nsee 6.1.3.1.16 functional test object, na metallic item that doesnot necessarily have strict criteria defining its size, form,weight, or composition.3.1.16.1 DiscussionFunctional test objects do not testsensitivity; they are

37、gross stimuli used frequently to quicklyverify that the aural and visual indicators and alarm circuits areoperable.3.1.16.2 DiscussionA functional test object will consis-tently cause metal detection alarms when a detector is adjustedto detect the critical test object in its critical orientation pas

38、singthrough the critical test path. Detection of the functional testobject does not provide assurance that the detector is operatingproperly or adjusted to detect anything other than the func-tional test object.3.1.16.3 DiscussionFunctional test objects may be itemssuch as large handguns or rifles,

39、metal tools, metal blocks, aperson wearing many metallic items, etc. Active devices suchas radios and pagers must not be used as functional test objectsand must not be carried when performing tests. The functionaltest object must be at least as detectable as the critical testobject in its critical o

40、rientation.3.1.17 grid, nsee test grid3.1.18 grid element, n(1) a single block on a detectionsensitivity map; (2) the rectilinear volume through the detec-tion zone defined by coincident elements of identical gridworks placed on either side of the portal aperture. (See Figs. 3and 4)3.1.18.1 Discussi

41、onGrid elements define the bounds ofrepeatable straight-line shortest-course paths through the de-tection zone (see Fig. 4).3.1.19 in-plant, adjinstalled in the location, position, andoperating environment where the device will be routinely used.3.1.20 normal screening method, nthe usual method ofpa

42、ssage through a walk-through metal detector during normaloperations. For example, the two basic screening methods are“continuous walk” and “pausing in the portal.”3.1.20.1 DiscussionThe normal screening method is usu-ally based on the operating characteristics of the detector. Abasic rule for metal

43、detector testing is:“ Use it like you test itand test it like you use it.”3.1.21 orthogonal orientation, nas used in this practice,orthogonal orientation refers to alignment of the longitudinal(long) axis of a test object along the XYZ axes of the Cartesiancoordinate system; X is horizontal and acro

44、ss the portal; Y isvertical; and Z is in the direction of travel through the portal.(See Fig. 2 for handgun orientations)3.1.21.1 In the case of firearms, the barrel is always treatedas the longitudinal axis. Fig. 2 illustrates the six standardorthogonal orientations for a handgun.3.1.22 performance

45、 test log, na record of the operation,testing, and maintenance history of a metal detector.3.1.22.1 DiscussionAppendix X4, Performance Test Log,suggests examples for log content and format.3.1.23 portal, nsee walk-through metal detector.3.1.24 shielding test object, na test object representingspecia

46、l nuclear material shielding that might be used in a theftscenario.3.1.24.1 DiscussionIt is usually a metallic container ormetallic material configured as a credible gamma radiationshield for a specific type and quantity of special nuclearmaterial. The object is specified by a regulatory authority o

47、r isbased on the facility threat/risk assessment, or both3.1.25 test element, n(see Fig. 1) for the purpose oftesting, it is necessary to define discrete and repeatablestraight-line shortest-course test paths through the detectionzone. This can be done by using two identical networks (grids)made of

48、nonconductive/nonmagnetic material attached acrossthe entry and exit planes of the portal aperture so the networkscoincide.Atest object on the end of a probe can then be passedfrom one side of the portal aperture to the other side throughcorresponding openings, which results in the test object takin

49、ga reasonably straight-line shortest-course path through thedetection zone. If the networks are constructed so that they canbe put in-place identically each time they are used, then the testpaths through the detection zone are repeatable over time.Thus, a test element is the volume of space defined by theboundaries of two corresponding network openings and itrepresents a straight-line shortest-course path through thedetection zone.3.1.25.1 DiscussionOn a detection sensitivity map thecorresponding networks appear as a rectangular grid w

展开阅读全文