1、Designation: C1403 06C1403 12Standard Test Method forRate of Water Absorption of Masonry Mortars1This standard is issued under the fixed designation C1403; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision.

2、A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers a standardized laboratory procedure for determining the relative water absorption by capillaryuptake (wickin

3、g) characteristics of masonry mortars. This test method is not applicable for determining the effectiveness of waterrepellent coatings.1.2 The values stated in SI units are to be regarded as the standard. The inch-pound units given in parentheses are forinformation only.No other units of measurement

4、 are included in this standard.1.2.1 Inch-pound units are given in parentheses for temperature specification and are for information only.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to

5、 establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C109/C109M Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or 50-mm Cube Specimens)C270 Specification for

6、Mortar for Unit MasonryC305 Practice for Mechanical Mixing of Hydraulic Cement Pastes and Mortars of Plastic ConsistencyC511 Specification for Mixing Rooms, Moist Cabinets, Moist Rooms, and Water Storage Tanks Used in the Testing of HydraulicCements and ConcretesC778 Specification for SandC1180 Term

7、inology of Mortar and Grout for Unit MasonryC1437 Test Method for Flow of Hydraulic Cement Mortar3. Terminology3.1 DefinitionsFor definitions of terms used in this test method, refer to Terminology C1180.4. Significance and Use4.1 This test method provides a laboratory procedure for determining the

8、relative water absorption properties over time ofmortars used for masonry construction. Because the specimens are made under laboratory conditions and do not take into accountthe effect of the masonry substrate or field mixing procedures, this method is not intended for field use. Data generated fro

9、m thistest method may be useful for determining the relative effectiveness of water repellent admixtures or the effect of other admixturesor mortar components on the water repellency of a mortar. However, use caution in interpreting the results. While the resistanceof masonry to water penetration ma

10、y be related to the water absorption of the mortar, it also depends on other factors, such as theworkmanship, extent of bond, and the properties of the masonry units and mortar.5. Apparatus5.1 BalanceA balance sensitive readable and accurate to 0.1 g.1 This test method is under the jurisdiction of A

11、STM Committee C12 on Mortars and Grouts for Unit Masonryand is the direct responsibility of Subcommittee C12.02on Research and Methods of Test.Current edition approved Dec. 15, 2006Dec. 15, 2012. Published January 2007January 2013. Originally approved in 1999. Last previous edition approved in 20052

12、006as C1403 05.C1403 06. DOI: 10.1520/C1403-06.10.1520/C1403-12.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM websi

13、te.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior

14、editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-

15、2959. United States15.2 Uptake ContainerA watertight container with a minimum cross sectional area that is at least 50 % greater than the totalarea of the specimens test surface(s) and a minimum depth of 75 mm (3 in.). mm. Provide a cover for the container to minimizeevaporation.5.2.1 Use specimen s

16、upports that allow a minimum of 3 mm (0.12 in.) clearance from the bottom of the container and that covera maximum of 10 % of the area of the specimens test surface. Use supports made of a material that does not float in water andthat does not rust, expand, or contract as a result of water exposure.

17、5.2.2 The container shall be flat so that when a specimen is set on the supports the water level as specified in 7.4 shall not varyby more than 1 mm (0.04 in.) from one end of the specimen to the opposite end.5.3 Specimen MoldsMetal nominal 50-mm or 2-in. cube specimen molds with removable plastic w

18、ater tight disposable liners.The plastic liners shall be rigid enough to retain their shape when free standing and filled with mortar.NOTE 1For this test method, actual specimen dimensions are measured and used to calculate absorption per a unit area; therefore, 2-in. cube specimenmolds can be used

19、interchangeably with 50-mm cube specimen molds.5.4 SpoonA metal spoon approximately 230 mm (9 in.) in length and with a bowl approximately 100 mm (4 in.) in length.5.5 StraightedgeA steel straightedge not less than 150 mm (6 in.) long and approximately 1.5-3.0 mm (1.5 116to 18 in.)3.0mm thick.5.6 Ta

20、mperA tamper made of a nonabsorptive, nonabrasive, nonbrittle material such as a rubber compound having a ShoreA durometer hardness of 80 6 10, or seasoned oak wood rendered nonabsorptive by immersion for 15 minutes in paraffin atapproximately 200C (392F), and having a cross section of 13 by 25 mm (

21、0.5 by 1.0 in.) and a convenient length of 127 to 152mm (5 to 6 in.). mm. The tamping face of the tamper shall be flat and at right angles to the length of the tamper.5.7 Trowel, having a steel blade 100 to 150 mm (4 to 6 in.) in length, with straight edges.5.8 Tapping StickA hardwood rod, having a

22、diameter of 16 mm (58 in.) and a length of 150 mm (6 in.).mm.5.9 Timing DeviceA suitable timing device capable of indicating elapsed time up to 24 h to the nearest 1 min.5.10 CalipersSuitable calipers with parallel jaws for measuring the dimensions of the hardened specimens to the nearest 0.5mm.6. S

23、pecimen Preparation6.1 Prepare mortar according to Practice C305, adjusting the water as necessary to obtain a flow of 110 6 5 as determined byTest Method C1437. Record the flow. If an admixture is being added to the mortar, the dosage rate, time of addition, and mixingsequence shall follow the manu

24、facturers recommendation. If there is no manufacturers recommendation, add a liquid admixturewith the water and add a dry admixture with the cementitious components. Record the type and amount of each material by weightused in the mortar. In addition, record the type and amount by weight or volume o

25、f any admixture used and when it was addedto the mix. If applicable, record the kind of mortar (cement-lime, mortar cement, or masonry cement), the type (O, N, S, or M),and whether the mortar is made to the proportion or property specification of Specification C270.6.1.1 To test the behavior of mort

26、ar components independent of the qualities of the masonry sand use a blend of equal parts byweight of graded standard sand and standard 20 - 30 sand conforming to Specification C778.6.2 Prepare 50-mm or 2-in. cube specimens according to Test Method C109/C109M except the mortar shall be the mortarpre

27、pared in 6.1 and the molds shall be as specified in 5.3. Make a minimum of three replicate specimens from each mortar batch.6.3 Immediately upon completion of casting, place the test specimens in a moist closet or moist room conforming to therequirements of Specification C511. Keep all test specimen

28、s in their molds and in the moist closet or moist room for 24 6 1 h withtheir upper surfaces exposed to the moist air but protected from dripping water.6.4 At 24 6 1 h from the time of mixing remove the specimens from the molds. Mark the side of each specimen indicatingwhich surface is top, as cast.

29、 Cure the specimens in a moisture tight plastic bag at 24 6 8C (75 6 15F) for a total 28 days fromthe time of casting.6.5 At the age of 28 days 6 12 h from the time of casting, remove the specimens from the plastic bag and dry in a ventilatedoven at 110 to 115C (230 to 240F) for not less than 24 h a

30、nd until two successive weighings at intervals of 2 h show an incrementof loss not greater than 0.2 % of the last previously determined weight of the specimen. Remove the specimens from the oven andcool in ambient conditions (24 6 8C (75 6 15F) and a relative humidity of less than 80 % for a minimum

31、 of 2 h and until thespecimens reach ambient temperature. Begin testing within 24 h after reaching ambient temperature.7. Procedure7.1 Calculate the area of the test surface for each specimen from the length and width of the test surface. The test surface isthe top face of the cube, as cast. Using c

32、alipers, measure the length of the cube test surface to the nearest 0.5 mm at three locationsC1403 122along its height and record as L1 the average length in millimetres to the nearest 0.5 mm. Using calipers, measure the width ofthe cube test surface to the nearest 0.5 mm at three locations along it

33、s height and record as L2 the average width in millimetresto the nearest 0.5 mm.7.2 Record as W0 the initial weight in grams to the nearest 0.1 g of each individual specimen immediately prior to testing.7.3 Place the uptake container on a flat level surface. Place all specimens in the uptake contain

34、er(s) with their top faces, as cast,in contact with the specimen supports as illustrated in Fig. 1. Provide a minimum space of 12 mm between specimens and 25 mmbetween specimens and the wall of the uptake container.7.4 Add room temperature (24 6 8C (75 6 15F) water to the uptake container(s) so that

35、 the specimens are partially immersedin 3.060.5 mm (0.1260.02 in.) of water.When adding water make sure not to splash water onto the specimens. Cover the uptakecontainer(s) to minimize evaporation.7.5 Monitor the specimens during the first 1 min and after 5 6 1 min to make sure the water level is ad

36、equate during the initialabsorption phase. Add water as necessary to maintain the immersion depth as specified in 7.4. When adding water make sure notto splash water onto the specimens. Cover the uptake container(s) to minimize evaporation.7.6 At 0.25, 1, 4, and 24 h, measure the weight in grams to

37、the nearest 0.1 g of each specimen and record as WT where T isthe measurement time in hours. Wipe off surface water from each specimen with a damp cloth prior to each weighing (see Note12). Complete the wipe within 10 s of removal from contact with the water and complete weighing within 1 min.NOTE 2

38、The wipe-off cloth should be damp enough so it does not wick water off the specimen surface but not so damp that it is dripping water.Experience has shown that the cloth may need to be wrung out every 8 to 12 cubes to keep it from getting too wet.7.7 After each weighing, replace the specimens into t

39、he uptake container(s) and add water as necessary to maintain theimmersion depth specified in 7.4. When adding water, make sure not to splash water onto the specimens. Re-cover the uptakecontainer(s).8. Calculation8.1 Calculate and record as AT the water absorption in grams/100 cm2, at each time per

40、iod, T, for each specimen, as follows:AT 5WT 2W0!310 000/L13L2! (1)where:WT = the weight of the specimen at time T in grams to the nearest 0.1 g,W0 = the initial weight of the specimen in grams to the nearest 0.1 g,L1 = the average length of the test surface of the mortar specimen cube in mm to the

41、nearest 0.5 mm, andL2 = the average width of the test surface of the mortar specimen cube in mm to the nearest 0.5 mm.8.2 Calculate and record as, AT (avg), the average AT for each set of three or more replicate specimens at each time interval.9. Report9.1 Report the mortar mixture, as follows:9.1.1

42、 The type and amount of each material by weight used in the mortar,9.1.2 The type and amount by weight or volume of any admixture used in the mortar and when it was added to the mix,9.1.3 The actual flow of the mortar batch(es), and9.1.4 If applicable:FIG. 1 Specimen Configuration During TestingC140

43、3 1239.1.4.1 The kind of mortar (cement-lime, mortar cement, or masonry cement),9.1.4.2 The type (O, N, S, or M) used, and9.1.4.3 Whether the mortar was made to the proportion or property specification of Specification C270.9.2 Report the water absorption test results, as follows:9.2.1 For each spec

44、imen, report:9.2.1.1 L1, the average length of the test surface of the mortar specimen cube in mm to the nearest 0.5 mm,9.2.1.2 L2, the average width of the test surface of the mortar specimen cube in mm to the nearest 0.5 mm,9.2.1.3 W0, the initial weight of the specimen in g to the nearest 0.1 g,9

45、.2.1.4 WT, the weight of the specimen at each time T in g to the nearest 0.1 g, and9.2.1.5 AT, the water absorption of the specimen at each time T in g/100 cm2.9.2.2 For each set of three or more replicates, report:9.2.2.1 AT (avg), the average water absorption at each time T in g/100 cm2.10. Precis

46、ion and Bias10.1 A precision and bias statement is not available for this test method.11. Keywords11.1 absorption; absorption rate; masonry mortar; water repellentSUMMARY OF CHANGESCommittee C12 has identified the location of selected changes to this standard since the last issue(C1403 05C1403 06) t

47、hat may impact the use of this standard. (Approved Dec. 15, 2006Dec. 15, 2012.)(1) Section 5.1 was modified to clarify balance requirements.(2) Subsection 2.1 was revised and Section 37.3 was addedand Fig. 1 to reference Terminologywere revised to include spacingC1180 for definitions of terms used i

48、n this test method.All subsequent sections were renumbered. requirements between specimensand between specimens and the wall of the uptake container.(3) Units information was editorially corrected.ASTM International takes no position respecting the validity of any patent rights asserted in connectio

49、n with any item mentionedin this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn.Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International H