1、Designation: C1655 06 (Reapproved 2016)Standard Classification ofFireclay and High-Alumina Mortars1This standard is issued under the fixed designation C1655; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision

2、. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This classification pertains to fireclay and high-aluminarefractory mortars that can be trowelled, dipped or painted tojoin or coat

3、 refractory bricks and shapes.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.3 This standard does not purport to address safetycon

4、cerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety andhealth practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C199 Test Method for Pier Test for Refract

5、ory MortarsC27 Classification of Fireclay and High-Alumina RefractoryBrick3. Significance and Use3.1 Refractory mortars are used for laying, bonding andcoating refractory brick. They become an integral part of theresulting refractory lining or structure. Therefore, such mortarsshould be selected in

6、order to closely match those of the brick.A classification system is provided for use in producing,purchasing and using different types of refractory mortars.4. Basis of Classification4.1 Heat-Setting Mortars This class hardens at elevatedtemperature by forming a ceramic bond. The minimum tem-peratu

7、re required for forming the ceramic bond is usually atleast 2000 F (1095 C).4.2 Air-Setting Mortars This class initially hardens atambient temperatures in contact with air and forms a strongbond upon drying at 230 F (110 C).4.3 Chemically Bonded Mortars Mortars in this classcannot be said to truly a

8、irset, since they require some heatingto initiate hardening. However, they harden at temperatureslower than those required for ceramic bonding. A commonexample of a chemically bonded mortar is a phosphate-bondedmortar.4.4 Each of the above classes of mortar are further classifiedby the condition in

9、which they are supplied:4.4.1 Dry Mortars This class is supplied dry and must bemixed with water prior to use.4.4.2 Wet Mortars This class is supplied in a ready for use.4.5 The above classes of mortars are further classified forusage with a particular type of brick as prescribed in Table 1.5. Test

10、Methods5.1 The properties enumerated in this classification shall bedetermined in accordance with the following ASTM testmethods:5.1.1 Pier Test Test Method C199. For medium-duty,high-duty, super-duty and high-alumina mortar classes testwith appropriate brick that meet requirements specified in Test

11、Method C199. For high-alumina mortars in the 80 %, 85 %,90 %, and 99 % classes test with high-alumina brick from theappropriate class meeting the requirements specified in Clas-sification C27.5.1.2 Alumina Content XRF and ICP after calcining to1830 F (1000 C).6. Retests6.1 Because of possible variab

12、les that may result fromsampling or an unsatisfactory reproducibility of tests bydifferent laboratories, the material may be resampled andretested at the request of either purchaser or the manufacturer.This could apply where the first test results may not conform tothe requirements prescribed in thi

13、s classification. Therefore,the final results to be used shall be the average of at least twoseries of tests, each of which has been obtained by followingthe testing procedures in detail.1This practice is under the jurisdiction ofASTM Committee C08 on Refractoriesand is the direct responsibility of

14、Subcommittee C08.92 on The Joseph E. KopandaSubcommittee for Editorial, Terminology and Classification.Current edition approved June 1, 2016. Published June 2016. Originallyapproved in 1976. Last previous edition approved in 2011 as C1655 06(2011).DOI: 10.1520/C1655-06R16.2For referenced ASTM standa

15、rds, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA

16、19428-2959. United States17. Keywords7.1 classification; fireclay mortars; high-alumina mortarsASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determina

17、tion of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or with

18、drawn. Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that you

19、r comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (sing

20、le or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org). Permission rights to photocopy the standard may also be secured from the Copyright Cl

21、earance Center, 222Rosewood Drive, Danvers, MA 01923, Tel: (978) 646-2600; http:/ 1 Classification of Fireclay and High-Alumina MortarsClass of Brick Class of MortarNo Flow from Joints in Pier Test (Test MethodC199) when fired to:Minimum Alumina (Al2O3) content, %Medium-Duty Medium-Duty 2550F (1400C

22、)High-Duty High-Duty 2730F (1500C)Super-Duty Super-Duty 2910F (1600C)High-Alumina up 70 % High-Alumina 3100F (1705C)High-Alumina 80 % High-Alumina 80 % 3100F (1705C) 77.5High-Alumina 85 % High-Alumina 85 % 3100F (1705C) 83.0High-Alumina 90 % High-Alumina 90 % 3100F (1705C) 88.0High-Alumina 99 % High-Alumina 99 % 3100F (1705C) 97.0C1655 06 (2016)2