ASTM C231 C231M-2014 Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method《使用压力法测定新搅拌混凝土中空气含量的标准试验方法》.pdf

上传人:feelhesitate105 文档编号:466083 上传时间:2018-11-27 格式:PDF 页数:11 大小:248.46KB
下载 相关 举报
ASTM C231 C231M-2014 Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method《使用压力法测定新搅拌混凝土中空气含量的标准试验方法》.pdf_第1页
第1页 / 共11页
ASTM C231 C231M-2014 Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method《使用压力法测定新搅拌混凝土中空气含量的标准试验方法》.pdf_第2页
第2页 / 共11页
ASTM C231 C231M-2014 Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method《使用压力法测定新搅拌混凝土中空气含量的标准试验方法》.pdf_第3页
第3页 / 共11页
ASTM C231 C231M-2014 Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method《使用压力法测定新搅拌混凝土中空气含量的标准试验方法》.pdf_第4页
第4页 / 共11页
ASTM C231 C231M-2014 Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method《使用压力法测定新搅拌混凝土中空气含量的标准试验方法》.pdf_第5页
第5页 / 共11页
亲,该文档总共11页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: C231/C231M 10C231/C231M 14Standard Test Method forAir Content of Freshly Mixed Concrete by the PressureMethod1This standard is issued under the fixed designation C231/C231M; the number immediately following the designation indicates the yearof original adoption or, in the case of revisi

2、on, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers determination of the air content of freshly mixed concrete from observation o

3、f the change in volumeof concrete with a change in pressure.1.2 This test method is intended for use with concretes and mortars made with relatively dense aggregates for which theaggregate correction factor can be satisfactorily determined by the technique described in Section 6. It is not applicabl

4、e to concretesmade with lightweight aggregates, air-cooled blast-furnace slag, or aggregates of high porosity. In these cases, Test MethodC173/C173M should be used. This test method is also not applicable to nonplastic concrete such as is commonly used in themanufacture of pipe and concrete masonry

5、units.1.3 The text of this test method references notes and footnotes that provide explanatory information. These notes and footnotes(excluding those in tables and figures) shall not be considered as requirements of this standard.1.4 The values stated in either SI units or inch-pound units are to be

6、 regarded separately as standard. The values stated in eachsystem may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from thetwo systems may result in non-conformance with the standard.1.5 This standard does not purport to address all of t

7、he safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use. (WarningFresh hydraulic cementitious mixtures are caustic and may caus

8、e chemical burns to skin andtissue upon prolonged exposure.WarningFresh hydraulic cementitious mixtures are caustic and may cause chemical burns toskin and tissue upon prolonged exposure.)2)2. Referenced Documents2.1 ASTM Standards:3C31/C31M Practice for Making and Curing Concrete Test Specimens in

9、the FieldC138/C138M Test Method for Density (Unit Weight), Yield, and Air Content (Gravimetric) of ConcreteC143/C143M Test Method for Slump of Hydraulic-Cement ConcreteC172 Practice for Sampling Freshly Mixed ConcreteC173/C173M Test Method for Air Content of Freshly Mixed Concrete by the Volumetric

10、MethodC192/C192M Practice for Making and Curing Concrete Test Specimens in the LaboratoryC670 Practice for Preparing Precision and Bias Statements for Test Methods for Construction MaterialsE177 Practice for Use of the Terms Precision and Bias in ASTM Test Methods3. Significance and Use3.1 This test

11、 method covers the determination of the air content of freshly mixed concrete. The test determines the air contentof freshly mixed concrete exclusive of any air that may exist inside voids within aggregate particles. For this reason, it is applicableto concrete made with relatively dense aggregate p

12、articles and requires determination of the aggregate correction factor (see 6.1and 9.1).1 This test method is under the jurisdiction of ASTM Committee C09 on Concrete and Concrete Aggregatesand is the direct responsibility of Subcommittee C09.60 onTesting Fresh Concrete.Current edition approved Oct.

13、 1, 2010June 1, 2014. Published November 2010June 2014. Originally approved in 1949. Last previous edition approved in 20092010 asC231/C231M09b. DOI: 10.1520/C0231_C0231M-10. 10. DOI: 10.1520/C0231_C0231M-14.2 Section on Safety Precautions, Manual of Aggregate and Concrete Testing, Annual Book of AS

14、TM Standards, Vol 04.02.3 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard

15、 and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases on

16、ly the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.2 This test method

17、 and Test Method C138/C138M and C173/C173M provide pressure, gravimetric, and volumetricprocedures, respectively, for determining the air content of freshly mixed concrete. The pressure procedure of this test methodgives substantially the same air contents as the other two test methods for concretes

18、 made with dense aggregates.3.3 The air content of hardened concrete may be either higher or lower than that determined by this test method. This dependsupon the methods and amount of consolidation effort applied to the concrete from which the hardened concrete specimen is taken;uniformity and stabi

19、lity of the air bubbles in the fresh and hardened concrete; accuracy of the microscopic examination, if used;time of comparison; environmental exposure; stage in the delivery, placement and consolidation processes at which the air contentof the unhardened concrete is determined, that is, before or a

20、fter the concrete goes through a pump; and other factors.4. Apparatus4.1 Air MetersThere are available satisfactory apparatus of two basic operational designs employing the principle of Boyleslaw. For purposes of reference herein these are designated Meter Type A and Meter Type B.4.1.1 Meter Type AA

21、n air meter consisting of a measuring bowl and cover assembly (see Fig. 1) conforming to therequirements of 4.2 and 4.3. The operational principle of this meter consists of introducing water to a predetermined height abovea sample of concrete of known volume, and the application of a predetermined a

22、ir pressure over the water. The determinationconsists of the reduction in volume of the air in the concrete sample by observing the amount the water level is lowered under theapplied pressure, the latter amount being calibrated in terms of percent of air in the concrete sample.4.1.2 Meter Type BAn a

23、ir meter consisting of a measuring bowl and cover assembly (see Fig. 2) conforming to therequirements of 4.2 and 4.3. The operational principle of this meter consists of equalizing a known volume of air at a knownpressure in a sealed air chamber with the unknown volume of air in the concrete sample,

24、 the dial on the pressure gauge beingcalibrated in terms of percent air for the observed pressure at which equalization takes place. Working pressures of 50 to 205 kPa7.5 to 30.0 psi have been used satisfactorily.4.2 Measuring BowlThe measuring bowl shall be essentially cylindrical in shape, made of

25、 steel, hard metal, or other hardmaterial not readily attacked by the cement paste, having a minimum diameter equal to 0.75 to 1.25 times the height, and a capacityof at least 6.0 L 0.20 ft3. It shall be flanged or otherwise constructed to provide for a pressure tight fit between measuring bowland c

26、over assembly. The interior surfaces of the measuring bowl and surfaces of rims, flanges, and other component fitted partsshall be machined smooth. The measuring bowl and cover assembly shall be sufficiently rigid to limit the expansion factor, D, ofthe apparatus assembly (Annex(Section A1.5) to not

27、 more than 0.1 % of air content on the indicator scale when under normaloperating pressure.4.3 Cover Assembly:4.3.1 The cover assembly shall be made of steel, hard metal, or other hard material not readily attacked by the cement paste.It shall be flanged or otherwise constructed to provide for a pre

28、ssure-tight fit between measuring bowl and cover assembly and shallhave machined smooth interior surfaces contoured to provide an air space above the level of the top of the measuring bowl. Thecover shall be sufficiently rigid to limit the expansion factor of the apparatus assembly as prescribed in

29、4.2.FIG. 1 Illustration of the Pressure Method for Air ContentType-A MeterC231/C231M 1424.3.2 The cover assembly shall be fitted with a means of direct reading of the air content. The cover for the Type A meter shallbe fitted with a standpipe, made of a transparent graduated tube or a metal tube of

30、uniform bore with a glass water gauge attached.In the Type B meter, the dial of the pressure gauge shall be calibrated to indicate the percent of air. Graduations shall be providedfor a range in air content of at least 8 % readable to 0.1 % as determined by the proper air pressure calibration test.4

31、.3.3 The cover assembly shall be fitted with air valves, air bleeder valves, and petcocks for bleeding off or through which watermay be introduced as necessary for the particular meter design. Suitable means for clamping the cover to the measuring bowl shallbe provided to make a pressure-tight seal

32、without entrapping air at the joint between the flanges of the cover and measuring bowl.A suitable hand pump shall be provided with the cover either as an attachment or as an accessory.4.4 Calibration VesselA measure having an internal volume equal to a percent of the volume of the measuring bowlcor

33、responding to the approximate percent of air in the concrete to be tested; or, if smaller, it shall be possible to check calibrationof the meter indicator at the approximate percent of air in the concrete to be tested by repeated filling of the measure. When thedesign of the meter requires placing t

34、he calibration vessel within the measuring bowl to check calibration, the measure shall becylindrical in shape.NOTE 1A satisfactory calibration vessel to place within the measuring bowl may be machined from No. 16 gauge brass tubing, of a diameter toprovide the volume desired, to which a brass disk

35、13 mm 12 in. in thickness is soldered to form an end. When design of the meter requires withdrawingof water from the water-filled measuring bowl and cover assembly, to check calibration, the measure may be an integral part of the cover assembly ormay be a separate cylindrical measure similar to the

36、above-described cylinder.4.5 The designs of various available types of air meters are such that they differ in operating techniques; therefore, all of theitems described in 4.6 4.16 may not be required. The items required shall be those necessary for use with the particular designof apparatus used t

37、o satisfactorily determine air content in accordance with the procedures prescribed herein.4.6 Coil Spring or Other Device for Holding Calibration Cylinder in Place.4.7 Spray TubeA brass tube of appropriate diameter, which may be an integral part of the cover assembly, or which may beprovided separa

38、tely. It shall be so constructed that when water is added to the container, it is sprayed to the walls of the cover insuch a manner as to flow down the sides causing a minimum of disturbance to the concrete.4.8 TrowelA standard brick masons trowel.4.9 Tamping RodA round, smooth, straight steel rod,

39、with a 16 mm 58 in. 6 2 mm 116 in. diameter. The length of thetamping rod shall be at least 100 mm 4 in. greater than the depth of the measuring bowl in which rodding is being performed,but not greater than 600 mm 24 in. in overall length (See(see Note 2). The rod shall have the tamping end or both

40、ends roundedto a hemispherical tip of the same diameter as the rod.NOTE 2Arod length of 400 mm 16 in. to 600 mm 24 in. meets the requirements of the following: Practice C31/C31M, Test Method C138/C138M,Test Method C143/C143M, Test Method C173/C173M, and Test Method C231/C231M.FIG. 2 Schematic Diagra

41、mType-B MeterC231/C231M 1434.10 MalletA mallet (with a rubber or rawhide head) weighing approximately 0.60 6 0.25 kg 1.25 6 0.50 lb for use withmeasures of 14 L 0.5 ft 3 or smaller, and a mallet weighing approximately 1.0 6 0.25 kg 2.25 6 0.50 lb for use with measureslarger than 14 L 0.5 ft3.4.11 St

42、rike-Off BarA flat straight bar of steel or other suitable metal at least 3 mm 18 in. thick and 20 mm 34 in. wide by300 mm 12 in. long.4.12 Strike-Off PlateA flat rectangular metal plate at least 6 mm 14 in. thick or a glass or acrylic plate at least 13 mm 12in. thick with a length and width at leas

43、t 50 mm 2 in. greater than the diameter of the measure with which it is to be used. Theedges of the plate shall be straight and smooth within a tolerance of 1.5 mm 116 in.4.13 Funnel, with the spout fitting into spray tube.4.14 Measure for Water, having the necessary capacity to fill the indicator w

44、ith water from the top of the concrete to the zeromark.4.15 Vibrator, as described in Practice C192/C192M.4.16 Sieves, 37.5-mm (112-in.) with not less than 0.2 m2 2 ft2 of sieving area.4.17 Scoopof a size large enough so each amount of concrete obtained from the sampling receptacle is representative

45、 andsmall enough so it is not spilled during placement in the measuring bowl.5. Calibration of Apparatus5.1 Make calibration tests in accordance with procedures prescribed in the annex. Rough handling will affect the calibration ofboth Types A and B meters. Changes in barometric pressure will affect

46、 the calibration of Type A meter but not Type B meter. Thesteps described Sections A1.2 A1.6, as applicable to the meter type under consideration, are prerequisites for the final calibrationtest to determine the operating pressure, P, on the pressure gauge of the TypeAmeter as described in Section A

47、1.7, or to determinethe accuracy of the graduations indicating air content on the dial face of the pressure gauge of the Type B meter as described inSection A1.9. The steps in Sections A1.2 A1.6 need be made only once (at the time of initial calibration), or only occasionallyto check volume constanc

48、y of the calibration cylinder and measuring bowl. The calibration test described in Sections A1.7 andA1.9, as applicable to the meter type being checked, must be made as frequently as necessary and at intervals not to exceed threemonths to ensure that the proper gauge pressure, P, is being used for

49、the Type A meter or that the correct air contents are beingindicated on the pressure gauge air content scale for the Type B meter. A change in elevation of more than 180 m 600 ft fromthe location at which a Type A meter was last calibrated will require recalibration in accordance with Section A1.7.5.2 Calibration RecordsInformation to be maintained in the records shall include determination of expansion factor; size ofthe calibration vessel used; and the reading of the meter at the calibration test