ASTM D2852-1995(2008) Standard Specification for Styrene-Rubber (SR) Plastic Drain Pipe and Fittings《苯乙烯橡胶(SR)塑料排水管及配件的标准规范》.pdf

上传人:testyield361 文档编号:513639 上传时间:2018-12-02 格式:PDF 页数:6 大小:110.40KB
下载 相关 举报
ASTM D2852-1995(2008) Standard Specification for Styrene-Rubber (SR) Plastic Drain Pipe and Fittings《苯乙烯橡胶(SR)塑料排水管及配件的标准规范》.pdf_第1页
第1页 / 共6页
ASTM D2852-1995(2008) Standard Specification for Styrene-Rubber (SR) Plastic Drain Pipe and Fittings《苯乙烯橡胶(SR)塑料排水管及配件的标准规范》.pdf_第2页
第2页 / 共6页
ASTM D2852-1995(2008) Standard Specification for Styrene-Rubber (SR) Plastic Drain Pipe and Fittings《苯乙烯橡胶(SR)塑料排水管及配件的标准规范》.pdf_第3页
第3页 / 共6页
ASTM D2852-1995(2008) Standard Specification for Styrene-Rubber (SR) Plastic Drain Pipe and Fittings《苯乙烯橡胶(SR)塑料排水管及配件的标准规范》.pdf_第4页
第4页 / 共6页
ASTM D2852-1995(2008) Standard Specification for Styrene-Rubber (SR) Plastic Drain Pipe and Fittings《苯乙烯橡胶(SR)塑料排水管及配件的标准规范》.pdf_第5页
第5页 / 共6页
亲,该文档总共6页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: D 2852 95 (Reapproved 2008)An American National StandardStandard Specification forStyrene-Rubber (SR) Plastic Drain Pipe and Fittings1This standard is issued under the fixed designation D 2852; the number immediately following the designation indicates the year oforiginal adoption or, i

2、n the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1

3、This specification covers requirements and test methodsfor materials, dimensions, workmanship, impact resistance,load-deflection properties, dimensional stability, and jointtightness of plain-end or bell-end styrene-rubber (SR) plasticdrain pipe and fittings in sizes 2 through 6 in.1.2 The values st

4、ated in inch-pound units are to be regardedas the standard. The values given in parentheses are forinformation only.1.3 The following safety hazards caveat pertains only to thetest methods portion, Section 8, of this specification: Thisstandard does not purport to address all of the safety concerns,

5、if any, associated with its use. It is the responsibility of the userof this standard to establish appropriate safety and healthpractices and determine the applicability of regulatory limita-tions prior to use.2. Referenced Documents2.1 ASTM Standards:2D 256 Test Methods for Determining the Izod Pen

6、dulumImpact Resistance of PlasticsD 618 Practice for Conditioning Plastics for TestingD 638 Test Method for Tensile Properties of PlasticsD 648 Test Method for Deflection Temperature of PlasticsUnder Flexural Load in the Edgewise PositionD 1600 Terminology for Abbreviated Terms Relating toPlasticsD

7、2122 Test Method for Determining Dimensions of Ther-moplastic Pipe and FittingsD 2321 Practice for Underground Installation of Thermo-plastic Pipe for Sewers and Other Gravity-Flow Applica-tionsD 2412 Test Method for Determination of External LoadingCharacteristics of Plastic Pipe by Parallel-Plate

8、LoadingD 2444 Test Method for Determination of the Impact Re-sistance of Thermoplastic Pipe and Fittings by Means of aTup (Falling Weight)D 3122 Specification for Solvent Cements for Styrene-Rubber (SR) Plastic Pipe and FittingsF 412 Terminology Relating to Plastic Piping Systems2.2 Federal Standard

9、:Fed. Std. No. 123 Marking for Shipment (Civil Agencies)32.3 Military Standard:MIL-STD-129 Marking for Shipment and Storage33. Terminology3.1 DefinitionsDefinitions are in accordance with Termi-nology F 412, and abbreviations are in accordance with Ter-minology D 1600, unless otherwise specified. Th

10、e abbreviationfor styrene-rubber plastics is SR.4. Significance and Use4.1 The requirements for this specification are intended toprovide pipe and fittings suitable for nonpressure undergrounddrainage of sewage and certain other liquid wastes, in appli-cations outside the building limits, where dime

11、nsional stability,resistance to aging, and strong eight joints are required. Theplastic drain pipe and fittings described in this specification areintended for use in the following applications:4.1.1 House connections to septic tanks.4.1.2 Footing drains (foundation drains).4.1.3 Storm drainage.4.2

12、The pipe should be installed in accordance with PracticeD 2321.5. Materials and Manufacture5.1 MaterialsThe pipe and fittings shall be made ofstyrene-rubber (SR) plastics meeting the following require-ments:5.1.1 The SR plastics compound shall contain at least 50 %styrene plastics, combined with rub

13、bers to a minimum rubbercontent of 5 %, and compounding materials such as antioxi-dants and lubricants, and may contain up to 15 % acrylonitrile1This specification is under the jurisdiction of ASTM Committee F17 on PlasticPiping Systems and is the direct responsibility of Subcommittee F17.65 on Land

14、Drainage.Current edition approved March 1, 2008. Published May 2008. Originallyapproved in 1969. Last previous edition approved in 2002 as D 2852 95(2002).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTM

15、Standards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Standardization Documents Order Desk, DODSSP, Bldg. 4,Section D, 700 Robbins Ave., Philadelphia, PA 19111-5098, http:/www.dodssp.daps.mil.1Copyright ASTM International, 100 Barr Harbor Drive

16、, PO Box C700, West Conshohocken, PA 19428-2959, United Sbined in the styrene plastics or rubbers, or both. Therubbers shall be of the polybutadiene or butadiene-styrenetype, or both, with a maximum styrene content of 25 % ornitrile type. The combined styrene plastics and rubber contentshall be not

17、less than 90 %. No fillers may be used.5.1.2 The SR plastic compound shall meet the followingminimum requirements when tested in accordance with Section8:Tensile strength at rupture, 3800 psi (26.2 MPa)Elongation at rupture, %, 15Modulus of elasticity in tension, 300 000 psi (2068 MPa)Izod impact st

18、rength, notched 0.8 ftlbf/in. (42.5 J/m)Deflection temperature at 264 psi (1.82MPa), F (C)149 (65)5.1.3 Rework MaterialClean rework material, generatedfrom the manufacturers own pipe or fittings production, maybe used by the same manufacturer, provided that the pipe andfittings produced meet all of

19、the requirements of this specifi-cation.6. Workmanship, Finish, and Appearance6.1 WorkmanshipThe pipe shall be homogeneousthroughout and essentially uniform in color, opacity, density,and other properties. The inside and outside surfaces shall besemimatte or glossy in appearance and free of chalking

20、, sticky,or tacky material. The pipe walls shall be free of cracks, holes,blisters, voids, foreign inclusion, or other defects that arevisible to the naked eye and that may affect the wall integrity.Holes deliberately placed in perforated pipe are acceptable.The surfaces shall be free of excessive b

21、loom. Bloom orchalking may develop in pipe exposed to direct rays of the sun(ultraviolet radiant energy) for extended periods and conse-quently these requirements do not apply to pipe after extendedexposure to direct rays of the sun.6.2 Pipe Dimensions:6.2.1 Pipe DiametersThe outside and inside diam

22、eters ofthe pipe shall be within the tolerances given in Table 1 whentested in accordance with 8.6.1.6.2.2 Wall ThicknessPipe wall thickness shall meet therequirements of Table 1 when measured in accordance with8.6.2.6.2.3 Laying LengthThe laying length shall be 10 ft witha tolerance of 0 +12 in., u

23、nless otherwise specified. The layinglength shall be determined in accordance with 8.6.3.6.3 Fitting and Bell-End Dimensions:6.3.1 Socket DiametersThe inside diameters of the sock-ets shall comply with the dimensions in Table 2 when deter-mined in accordance with 8.7.1.6.3.2 Wall Thickness:6.3.2.1 F

24、or belled pipe and fittings fabricated from pipesections, the thickness of the belled section shall be consideredsatisfactory if the bell was formed from pipe meeting therequirements of Table 1.6.3.2.2 For molded fittings, the wall thickness of the water-way and socket or bell shall be no less than

25、the respectiveminimum thickness listed for the equivalent pipe wall in Table2. For reducing fittings or those with smaller inlets, theminimum wall thickness of each inlet shall be no less than theminimum wall thickness for that size pipe.6.3.3 Socket DepthThe socket depth shall be not less thanthat

26、shown in Table 2 when measured in accordance with 8.7.3.6.3.4 Laying LengthThe laying length shall meet therequirements shown in Table 3. All dimensions are minimumwith a negative tolerance of zero.6.4 Impact StrengthThe impact strength of the pipe andfittings shall not be less than the values given

27、 in Table 4 whentested in accordance with 8.9.NOTE 1This test is intended only as a quality control test, not as asimulated service test.6.5 Pipe StiffnessThe pipe stiffness at 5 % deflection shallbe not less than the values given in Table 5 when tested inaccordance with 8.10. This requirement does

28、not apply tofittings.NOTE 2The 5 % deflection criterion, which was arbitrarily selectedfor testing convenience, should not be considered as a limitation withrespect to in-use deflection. The engineer is responsible for establishingthe acceptable deflection limit.NOTE 3The strength and load-carrying

29、capabilities of plastic drainand sewer pipe are measured and reported as Pipe Stiffness, which isdetermined in accordance with Test Method D 2412. The term “crushstrength” is not applicable to plastic piping because (a) the values obtainedcan be significantly different, depending on the bedding, loa

30、ding, ortesting technique used; and (b) the term derives from rigid pipe and refersto its ultimate strength at rupture.6.6 FlatteningThe pipe shall show no evidence of split-ting, cracking, or breaking at 20 % deflection when tested inaccordance with 8.8.6.7 Dimensional StabilityThe average decrease

31、 in insidediameter of pipe and fittings shall not exceed 10 % when testedin accordance with 8.11.6.8 Solvent CementSolvent cements shall meet the re-quirements of Specification D 3122.6.9 Joint TightnessJoints made with pipe and fittings shallnot leak when tested in accordance with 8.12.TABLE 1 Dime

32、nsions and Tolerances for SR Plastic Drain Pipe, in. (mm)Nominal Size Average Outside DiameterPermissible Deviations ofthe Diameter from Mea-sured Average (Out-of-roundness)Minimum AverageInside DiameterMinimum WallThickness2 2.250 6 0.006 (57.2 6 0.15) 60.030 (60.76) 2.000 (50.8) 0.073 (1.85)3 3.25

33、0 6 0.008 (82.6 6 0.20) 60.040 (61.02) 2.875 (73.0) 0.100 (2.54)4 4.215 6 0.009 (104.8 6 0.23) 60.050 (61.27) 3.875 (98.4) 0.125 (3.18)5 5.300 6 0.010 (134.6 6 0.25) 60.060 (61.52) 4.875 (123.8) 0.150 (3.81)6 6.275 6 0.011 (159.4 6 0.28) 60.070 (61.78) 5.875 (149.2) 0.180 (4.57)D 2852 95 (2008)27. R

34、etest and Rejection7.1 If the results of any test(s) do not meet the requirementsof this specification, the test(s) may be conducted again inaccordance with an agreement between the purchaser and theseller. There shall be no agreement to lower the minimumrequirement of the specification by such mean

35、s as omittingtests that are a part of the specification, substituting ormodifying a test method, or by changing the specificationTABLE 2 Fitting Dimensions and Tolerances, in. (mm)NominalSizeA B C, min D, min E and F,minA2 2.264 6 0.006 (57.5 6 0.15) 2.245 6 0.006 (57.0 6 0.15)34 (19.1) 2 (50.8) 0.0

36、73 (1.85)3 3.271 6 0.008 (83.1 6 0.20) 3.245 6 0.008 (82.4 6 0.20) 112 (38.1) 278 (73.0) 0.100 (2.54)4 4.235 6 0.009 (107.6 6 0.23) 4.210 6 0.009 (106.9 6 0.23) 134 (44.5) 378 (98.4) 0.125 (3.18)5 5.330 6 0.010 (135.4 6 0.25) 5.295 6 0.010 (134.5 6 0.25) 2 (50.8) 478 (123.8) 0.150 (3.81)6 6.305 6 0.

37、011 (160.1 6 0.28) 6.270 6 0.011 (159.3 6 0.28) 212 (63.5) 578 (149.2) 0.180 (4.57)AFitting Wall ThicknessThe wall thickness is a minimum value except that a 610 % variation resulting from core shift is allowable. In such a case, the average of twoopposite wall thicknesses shall equal or exceed the

38、value shown in the table.TABLE 3 Fitting Minimum Laying Length Dimensions, in. (mm)Size G1 G2 G3 G4 G5 H J N21532 (29.4) 134 (31.8)1516 (23.8) 234 (57.2)12 (12.7) 378 (98.4)916 (14.3)332 (2.4)312132 (42.1) 278 (73.0) 138 (34.9) 314 (82.6)916 (14.3) 6 (152.4)1116 (17.5)18 (3.2)42532 (54.8) 31116 (93.

39、7) 134 (93.7) 5 (127.0)1516 (23.8) 7716 (188.9)78 (22.2)18 (3.2)521116 (68.3) 18 (3.2)63316 (81.0) 778 (200.0) 1516 (33.3) 138 (34.9)18 (3.2)D 2852 95 (2008)3limits. In retesting, the product requirements of this specifica-tion shall be met and the test methods designated in thespecification shall b

40、e followed. If, upon retest, failure occurs,the quantity of product represented by the test(s) does not meetthe requirements of this specification.8. Test Methods8.1 ConditioningCondition the specimens prior to test at73.4 6 3.6F (23 6 2C) and 50 6 5 % relative humidity fornot less than 40 h in acco

41、rdance with Procedure A of PracticeD 618, for those tests where conditioning is required and in allcases of disagreement.8.2 Test ConditionsConduct tests in the standard labora-tory atmosphere of 73.4 6 3.6F (23 6 2C) and 50 6 5%relative humidity, unless otherwise specified.8.3 Deflection Temperatur

42、eDetermine the deflection tem-perature in accordance with Test Method D 648. Injection moldtwo14 by12 by 5-in. (6.4 by 12.7 by 127-mm) test specimensunder conditions specified by the manufacturer. The test shallbe made only at a stress of 264 psi (1.82 MPa). An inertimmersion medium shall be used. T

43、he heating rate shall be 2 60.2C/min.8.4 Material Impact ResistanceDetermine the Izod im-pact resistance in accordance with Method A of Test MethodsD 256. Injection mold ten18 by12 by 212-in. test specimensunder conditions specified by the manufacturer. The notch shallbe produced by a machining oper

44、ation using a single-toothmilling cutter.8.5 Tensile PropertiesDetermine the tensile strength,elongation at rupture, and modulus of elasticity in accordancewith Test Method D 638. Injection mold five Type I testspecimens approximately18 in. (3.2 mm) thick under condi-tions specified by the manufactu

45、rer. The speed of testing shallbe 0.20 to 0.25 in. (5 to 6 mm)/min.8.6 Pipe Dimensions:8.6.1 Pipe Diameters:8.6.1.1 Measure the average outside diameter of the pipe inaccordance with Test Method D 2122. Use either a tapered-sleeve gage or a vernier circumferential wrap tape accurate to60.001 in. (60

46、.02 mm).8.6.1.2 Measure the average inside diameter of the pipe inaccordance with Test Method D 2122.8.6.2 Wall ThicknessMeasure the wall thickness in accor-dance with Test Method D 2122. Make sufficient readings, aminimum of six, to ensure that the minimum thickness hasbeen determined. Use a cylind

47、rical anvil tubing micrometeraccurate to 60.001 in. (60.02 mm).8.6.3 LengthDetermine the over-all length of the pipe inaccordance with Test Method D 2122 using a steel tape with atleast116-in. (1-mm) graduations. For belled or coupled pipe,determine the laying length by measuring the bell or couplin

48、gsocket depth with a steel rule with at least116-in. graduationsand subtracting this dimension from the overall length.8.7 Fitting and Bell-End Socket Dimensions:8.7.1 Socket DiametersMeasure the inside diameters ofthe sockets at the socket entrance and bottom, using an insidemicrometer accurate to

49、60.001 in. (60.02 mm) or a telescop-ing pin gage in conjunction with an outside micrometeraccurate to 60.001 in. Determine the average inside diametersat the entrance and the bottom of the socket by taking sufficientreadings at each position. Calculate the average inside diameterat each position by taking the mean of the minimum andmaximum values.8.7.2 Wall ThicknessMeasure the wall thickness in accor-dance with Test Method D 2122. Make sufficent readings, aminimum of six