1、Designation: D 3890 05Standard Test Method forNumber of Strokes to Prime a Mechanical Pump Dispenser1This standard is issued under the fixed designation D 3890; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revis

2、ion. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the numberof actuations required to prime a pump dispenser (spray andflow types) w

3、ith a consumer-type product.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations

4、prior to use.2. Significance and Use2.1 This test method can be used to visually comparepriming characteristics of different pump dispensers and dif-ferent products.2.2 This test method is suitable for establishing specifica-tions for both the pump dispenser and the final package.3. Apparatus3.1 No

5、apparatus is required, although a mechanical devicefor actuating the pump dispenser may be used.4. Sampling4.1 Select an appropriate number of dry, unused pumpdispensers at random for the precision and accuracy desired. Anumber of ten test specimens are recommended, but a mini-mum of three is accept

6、able.5. Conditioning5.1 If possible, condition the test specimens at 23 6 3C (736 5.4F) for not less than 4 h. If the test specimens are notconditioned at the recommended temperature, this should benoted in the test report discussed in 8.1.5.2 Test pumps should be tested no sooner than 24 h afterass

7、embly when possible. If the pumps are not conditioned atthe recommended time, this should be noted in the test reportdiscussed in 8.1.6. Test Specimens6.1 For each test specimen, select a container to which thepump dispenser will be attached during the test. Since the diptube length affects the numb

8、er of strokes to prime, the actualbottle of the final package is recommended for testing.7. Procedure7.1 Fill each container with the product to be tested at theactual level of the final package target weight.7.2 Attach the pump dispenser securely to the container. Thepump should be in the off, lock

9、ed, or closed position. Take carenot to actuate the pump dispenser during this step.NOTE 1If the actuator is placed onto the pump after the pump hasbeen secured onto the container, then report this additional stroke in thefinal results in 8.1.NOTE 2If an actuation is required when opening or unlocki

10、ng thepump, then report this additional actuation in the test report discussed in8.1.7.3 If the pump dispenser is equipped with an overcap orlocking feature, remove or release the feature to permit thepump dispenser to be in the operable mode.7.4 If the pump dispenser has a variable output-per-strok

11、efeature, make an appropriate adjustment to achieve the desiredoutput-per-stroke at this time. Report this desired dosage in8.1.7.5 Actuate the pump dispenser to its fullest extent withsmooth, firm, and even pressure. Allow the pump mechanismto fully return before beginning the next stroke.NOTE 3Dep

12、ending on the venting system, some mechanical pumpdispensers can have variation in the number of strokes-to-prime due to thetime that the priming vent is opened. It is suggested that a rate of 90 6 15strokes per minute be used. For some viscous products, this rate may betoo fast for the mechanical p

13、ump dispenser to fully return. If the rate ofactuation is outside of this rangefaster or slower, report in 8.1.7.6 Record the number of full strokes until the first fulldischarge of product is observed.NOTE 4If the visual determination of the first full stroke is notaccurate enough, the amount of pr

14、oduct dispensed by the mechanicalpump dispenser may be weighed after each stroke, and the amountdispensed would be determined by subtracting the post-stroke weight fromthe pre-stroke weight. The strokes-to-prime number to be recorded wouldthen be the count value that shows the first consistent weigh

15、t dispensed.1This test method is under the jurisdiction of ASTM Committee D10 onPackaging and is the direct responsibility of Subcommittee D10.32 on MechanicalDispensers.Current edition approved Oct. 1, 2005. Published November 2005. Originallyapproved in 1980. Last previous edition approved in 2001

16、 as D 3890 01.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.NOTE 5If the pump does not prime within 25 strokes, that pumpshould be inspected for the cause of not priming. This pump should bereported in 8, but not included in the st

17、atistical results.8. Report8.1 Report the following information:8.1.1 Product description, type of pump dispenser beingtested, dip tube length used, and for variable dosage pumps, thedosage selected,8.1.2 Mean, maximum, minimum, and standard deviationvalues required to prime the pump dispensers, and

18、8.1.3 The rate actuation if outside the specified range.9. Precision and Bias9.1 PrecisionThe precision of Test Method D 3890 ishighly dependent on the particular pump style and contentstested. One laboratory has investigated one particular pumpstyle and a lotion product with 100 replicate tests, yi

19、elding anaverage of 8.59 strokes to prime with a range of 7 to 10 strokesand a standard deviation of 0.66 strokes. Other pumps andcontents will have other averages of strokes to prime and willhave more or less variability between replicate tests. Users ofthis test method are suggested to reference h

20、istorical files ofprevious tests of similar pumps and contents for an estimate ofwithinlaboratory repeatability. The committee believes thatbecause of this strong product and pump style dependency,further investigation of repeatability and reproducibility is notpracticable.9.2 BiasTest Method D 3890

21、 has no bias because anaccepted reference or referee value is not available.10. Keywords10.1 dispensing; mechanical pump dispenser;strokes-to-primeASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users o

22、f this standard are expressly advised that determination of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every fiv

23、e years andif not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical c

24、ommittee, which you may attend. If you feel that your comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org).D3890052