资源描述

1、Designation: D 4262 05Standard Test Method forpH of Chemically Cleaned or Etched Concrete Surfaces1This standard is issued under the fixed designation D 4262; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revisio

2、n. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers procedures for determining theacidity or alkalinity of concrete surfaces prepared by chemicalcleaning or

3、etching prior to coating.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations pri

4、or to use.2. Terminology2.1 Definitions:2.1.1 pH, na measure of acidity or alkalinity of a solutionor surface, with neutrality represented by a value of 7, withincreasing acidity represented by smaller values, and withincreasing alkalinity represented by increasing values.3. Significance and Use3.1

5、Chemical cleaning and etching is used to prepareconcrete for coating.3.2 Residual chemicals not removed by water rinsing mayadversely affect the performance and adhesion of coatingsapplied over prepared concrete surfaces. It is the intent of thistest method to determine that residual chemicals have

6、beenremoved by measuring the acidity or alkalinity of the finalrinsed surface.4. Apparatus4.1 The specific apparatus for each test is described inAnnex A1-Annex A3.5. Materials5.1 Potable Water, for rinsing chemically cleaned or etchedconcrete surfaces.5.2 Wet Concrete Surface, following the final w

7、ater rinseand before the rinse water has completely drained off thesurface.6. Procedure6.1 The preparatory actions for each alternative are de-scribed in Annex A1-Annex A3.6.2 At least two surface pH readings shall be taken for each500 square feet or portion thereof. Readings shall be taken atrandom

8、ly selected locations immediately following the finalrinse and before all the rinse water has drained off the surface.6.3 The pH of the water used for rinsing shall be determinedto establish acceptance criteria. Readings shall be taken at thebeginning and end of the final rinse.6.4 Unless otherwise

9、specified, tests shall be conducted inaccordance with this procedure.7. Acceptance Criteria7.1 The pH readings following the final rinse shall not bemore than 1.0 pH lower or 2.0 higher than the pH of the rinsewater unless otherwise specified.8. Keywords8.1 etched concrete surface; pH1This test meth

10、od is under the jurisdiction of ASTM Committee D33 onProtective Coating and Lining Work for Power Generation Facilities and is the directresponsibility of Subcommittee D33.05 on Application and Surface Preparation.Current edition approved March 1, 2005. Published March 2005. Originallyapproved in 19

11、83. Last previous edition approved in 1999 as D 4262 83 (1999).1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.ANNEXES(Mandatory Information)A1. pH TEST PAPER, TYPE 1A1.1 ApparatusA1.1.1 pH Test Paper, with a minimum range of 1 to 11

12、 pHunits with a capability of measuring in increments of 0.5 pHunits.A1.2 ProcedureA1.2.1 Tear off a strip of test paper, wet with test water andafter the color develops, compare with color chart to determinepH.A2. pHYDRION INSTA-CHECK pH PENCILA2.1 ApparatusA2.1.1 pH Pencil, a marking instrument ca

13、pable of measur-ing the surface pH from 0 to 13.A2.1.2 Color Comparison Chart.A2.2 ProcedureA2.2.1 Scratch the surface of the concrete with a metallicobject.A2.2.2 Moisten the surface with distilled water.A2.2.3 Mark over the scratch with pHydiron pencil.2A2.2.4 After 15 s, compare the color with th

14、e color com-parison chart.A2.2.5 The color produced is stable for several days.A3. pH METER3A3.1 ApparatusA3.1.1 Flat Electrode pH Pen, with a minimum range from0 pH to 14 pH units with the capability of measuring inincrements of 0.01 pH units.A3.2 ProcedureA3.2.1 Place the tip of the electrode into

15、 the test water. ThepH reading will appear in the display.ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determination of the validity of any such pate

16、nt rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invited eith

17、er for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your comments have not received a fair h

18、earing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standa

19、rd may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org).2The pHydrion pencil is available from Micro Essential Laboratories, Inc., 4224Avenue H, Brooklyn, Ny 11210.3The Model PH100 and PH110 pH meter is available from ExTech Instruments,285 Bear Hill Road, Waltham, MA 024511064.D4262052